02^0C:70:61^Error^Uncorrectable multibit ECC error has occurred^ ^ 
E0^36^Warning^CPU failed late self test^FPL_IndicationProvider^215
E0^37^Warning^The CPU late test has failed because of insufficient memory^FPL_IndicationProvider^216
E0^40^Critical^Could not allocate memory for EFI image^FPL_IndicationProvider^217
E0^78^Critical^Pal proc error copying pal to memory^FPL_IndicationProvider^244
E0^82^Warning^platform scratch RAM test failed^FPL_IndicationProvider^248
E0^85^Critical^Scratch RAM bad^FPL_IndicationProvider^251
E0^155^Critical^Error in temporary mdt area^FPL_IndicationProvider^293
E0^156^Critical^Failed to find lmmio entry in mdt^FPL_IndicationProvider^294
E0^157^Critical^Memory page zero bad^FPL_IndicationProvider^295
E0^158^Critical^Failed to find space in mdt^FPL_IndicationProvider^296
E0^161^Warning^Memory ECC normal write/read test failed^FPL_IndicationProvider^299
E0^171^Warning^DIMM loading order error:  DIMM  deallocated^FPL_IndicationProvider^300
E0^172^Warning^DIMM SPD checksum failed^FPL_IndicationProvider^301
E0^173^Warning^DIMM SPD error^FPL_IndicationProvider^4565
E0^174^Warning^Unsupported memory DIMM type^FPL_IndicationProvider^303
E0^175^Warning^The DIMM type of this DIMM doesn't match with others in the DIMM group^FPL_IndicationProvider^4571
E0^176^Warning^The DIMM type table is full. New DIMM type cannot be added.^FPL_IndicationProvider^4572
E0^179^Warning^DIMM number not found in DMT Table^FPL_IndicationProvider^306
E0^180^Warning^Memory ECC multiple-bit data error detection failed^FPL_IndicationProvider^307
E0^181^Warning^Memory ECC multiple-bit ECC error signaling failed^FPL_IndicationProvider^308
E0^182^Warning^Memory ECC single-bit data error detection failed^FPL_IndicationProvider^309
E0^183^Warning^Memory single-bit ECC error detection failed^FPL_IndicationProvider^310
E0^185^Warning^Insufficient memory for operation^FPL_IndicationProvider^6853
E0^186^Warning^Memory address not found in memory address routing registers^FPL_IndicationProvider^312
E0^187^Warning^Memory Error Information not cleared^FPL_IndicationProvider^313
E0^189^Warning^Couldn't clear memory error logs^FPL_IndicationProvider^4579
E0^190^Warning^Memory error clear failed^FPL_IndicationProvider^4580
E0^191^Warning^DIMM loading order error:  DIMM deallocated^FPL_IndicationProvider^4581
E0^193^Warning^Generic memory firmware error^FPL_IndicationProvider^2738
E0^199^Error^Memory interleaving algorithm failed^FPL_IndicationProvider^2903
E0^202^Critical^Memory interleave generation failed^FPL_IndicationProvider^2739
E0^204^Error^Uncorrectable multiple-bit ECC error in DIMM^FPL_IndicationProvider^4869
E0^204^Warning^Uncorrectable multiple-bit ECC error in DIMM^FPL_IndicationProvider^1038
E0^204^Error^Uncorrectable multiple-bit ECC error in DIMM^FPL_IndicationProvider^2451
E0^204^Warning^Uncorrectable multiple-bit ECC error in DIMM^FPL_IndicationProvider^2451
E0^205^Warning^Memory register test failed^FPL_IndicationProvider^319
E0^208^Critical^No memory DIMMs detected^FPL_IndicationProvider^4584
E0^209^Critical^No memory found^FPL_IndicationProvider^321
E0^211^Critical^Cannot log memory error because PDT is disabled^FPL_IndicationProvider^4589
E0^216^Error^Cannot add PDT entry-PDT full^FPL_IndicationProvider^4592
E0^218^Warning^Memory platform data update failure^FPL_IndicationProvider^2735
E0^219^Warning^Can't find memory rank entry^FPL_IndicationProvider^327
E0^237^Warning^Memory error overflow:^FPL_IndicationProvider^329
E0^238^Warning^Memory forward progress code invalid^FPL_IndicationProvider^330
E0^244^Warning^Memory error status invalid^FPL_IndicationProvider^331
E0^245^Warning^Memory error summary bits invalid^FPL_IndicationProvider^332
E0^248^Critical^Unexpected machine check during memory code^FPL_IndicationProvider^2685
E0^250^Warning^The DIMM distribution check was bypassed^FPL_IndicationProvider^2966
E0^253^Warning^Looping on destructive memory tests^FPL_IndicationProvider^4845
E0^255^Warning^DIMM Set Check has been skipped^FPL_IndicationProvider^336
E0^256^Warning^Serial Presence Detect (SPD) has been skipped^FPL_IndicationProvider^337
E0^257^Warning^An Alternate Memory Config has been loaded into the system^FPL_IndicationProvider^338
E0^278^Warning^Unspecified memory interleave error^FPL_IndicationProvider^4598
E0^447^Critical^Memory fetch timeout^FPL_IndicationProvider^379
E0^464^Error^DIMM SPD Extended Checksum Failure^FPL_IndicationProvider^4625
E0^478^Error^Error in constructing the Memory Descriptor.^FPL_IndicationProvider^397
E0^479^Error^Unable to update the local memory layout^FPL_IndicationProvider^398
E0^491^Critical^Internal firmware programming error.^FPL_IndicationProvider^402
E0^525^Warning^Copying memory test code failed.^FPL_IndicationProvider^421
E0^567^Error^This indicates the failure in collecting the Complex profile info.^FPL_IndicationProvider^563
E0^568^Error^This chassis code indicates the failure in collecting the cell info.^FPL_IndicationProvider^564
E0^569^Error^This indicates the failure in updating the  GNI info of the cell with CLM.^FPL_IndicationProvider^565
E0^570^Error^This indicates the failure in adjusting the mem info with Minimum ZI req.^FPL_IndicationProvider^566
E0^579^Critical^Internal Firmware Programming Error from the EFI portion of the firmware^FPL_IndicationProvider^570
E0^623^Warning^DIMM thermal loading order warning^FPL_IndicationProvider^435
E0^692^Critical^Internal Firmware Programming Error from the EFI portion of the firmware^FPL_IndicationProvider^453
E0^696^Critical^memory extender loading order error^FPL_IndicationProvider^454
E0^711^Warning^chipspare not supported on quad^FPL_IndicationProvider^460
E0^720^Critical^No I/O port space region found in the memory data table (MDT)^FPL_IndicationProvider^468
E0^731^Error^The PDH component encountered an error dealing with a property on a node.^FPL_IndicationProvider^478
E0^733^Error^Error encountered creating or initializing the ipmi node^FPL_IndicationProvider^480
E0^779^Warning^memory DIMM pair mismatch^FPL_IndicationProvider^4638
E0^788^Critical^EFI memory data table (MDT) table is bad^FPL_IndicationProvider^524
E0^795^Warning^memory DIMM quad mismatch^FPL_IndicationProvider^4639
E0^796^Warning^Firmware detected excessive errors on the DIMM.^FPL_IndicationProvider^530
E0^825^Warning^OS dump status  (EFxx)^FPL_IndicationProvider^549
E0^1002^Error^A memory address parity error was detected^FPL_IndicationProvider^5268
E0^1074^Error^A DIMM loading order error has occurred^FPL_IndicationProvider^590
E0^1146^Warning^Refresh Control Error Timeout^FPL_IndicationProvider^591
E0^1180^Warning^memory extender/baseboard FRU mismatch^FPL_IndicationProvider^592
E0^2663^Critical^During remote routing, the current port's neighbor is not healthy.^FPL_IndicationProvider^602
E0^2872^Warning^Failure to read data from a FRUID EEPROM^FPL_IndicationProvider^6774
E0^2896^Error^System FW and the PDHC have incompatible shared memory interface revisions^FPL_IndicationProvider^4954
E0^2903^Error^Power fault on cell board^FPL_IndicationProvider^708
E0^2963^Error^The XBC SBE and LPE errors were not cleared properly^FPL_IndicationProvider^1031
E0^2975^Error^A power converter on the cell has failed, but cell power is still good.^FPL_IndicationProvider^5258
E0^3139^Warning^The PDHC firmware was reset for some unknown reason.^FPL_IndicationProvider^634
E0^3219^Error^An error was encountered trying to relocate a slave cells registry^FPL_IndicationProvider^738
E0^3240^Critical^Internal firmware programming error in the PMI handler.^FPL_IndicationProvider^743
E0^3747^Error^Firmware was unable to find a suitable block of main memory to relocate ROM^FPL_IndicationProvider^1036
E0^3768^Warning^The echelon given in the data field is not fully populated.^FPL_IndicationProvider^816
E0^3821^Warning^Dimm at physical location in data field is not supported on this platform.^FPL_IndicationProvider^830
E0^3837^Warning^A dimm or CPU has been deconfigured or failed testing^FPL_IndicationProvider^832
E0^3839^Error^The cell will not join the PD^FPL_IndicationProvider^833
E0^3864^Warning^One of the BT errors occurred that results in abandoning memory dump.^FPL_IndicationProvider^843
E0^4000^Warning^DRAM failure on DIMM XX, deallocate rank^FPL_IndicationProvider^890
E0^4652^Warning^Predictive Failure in Memory^FPL_IndicationProvider^1805
E0^4682^Warning^Firmware unable to relocate VGA BIOS^FPL_IndicationProvider^986
E0^4750^Warning^Windows: Predictive Failure in Memory (Warning)^FPL_IndicationProvider^1820
E0^4751^Error^Windows: Predictive Failure in Memory (Critical)^FPL_IndicationProvider^1821
E0^5351^Critical^The maximum memory supported by this system has been exceeded.^FPL_IndicationProvider^2911
E0^5361^Error^A command to the memory buffer chip failed to complete.^FPL_IndicationProvider^2917
E0^5625^Warning^The checksum in the memory area of NVM is bad.  Memory NVM will be cleared.^FPL_IndicationProvider^4530
E0^5711^Critical^Physical memory allocation failure. This is always fatal to firmware.^FPL_IndicationProvider^4680
E0^5712^Critical^The internal hierarchical firmware database is corrupt and/or an operation on this database failed in an unexpected way. Such a failure is fatal.^FPL_IndicationProvider^4681
E0^5718^Critical^Memory allocation from SAL instance heap failed. (I.e., heap exhaustion)^FPL_IndicationProvider^4687
E0^5720^Critical^During cold boot, firmware could not allocate physical memory to back the IO tlb tables of an IOC. This should never occur in released firmware.^FPL_IndicationProvider^4689
E0^5769^Warning^core firmware physical memory heap failure^FPL_IndicationProvider^4754
E0^5814^Warning^Many corrected memory errors were detected in the memory subsystem^FPL_IndicationProvider^4542
E0^5823^Warning^Cache errors detected on a processor^FPL_IndicationProvider^4544
E0^5824^Warning^Corrected errors detected in the memory cache for a processor module^FPL_IndicationProvider^4545
E0^5827^Warning^Corrected errors detected in the memory tag for a processor module^FPL_IndicationProvider^4548
E0^5936^Warning^During launch of an fPar (cold boot or fPar directed reset), the BSP was unable to find memory necessary to instantiate the firmware interface instance for its fPar. The fPar will be disabled and will require reconfiguration and reset.^FPL_IndicationProvider^4708
E0^5993^Error^External Array accelerator reported bad data.^FPL_IndicationProvider^4737
E0^6530^Warning^Non-critical event announces that an fPar is enabled to boot but has inadequate memory resources to instantiate the firmware for the fPar. The configuration is modified to disable but not delete this fPar.^FPL_IndicationProvider^4931
E0^6531^Warning^Non-critical event announces that an fPar is enabled to boot but has no IO device and will not be able too boot beyond EFI shell interaction without reconfiguring and rebooting the fPar. The fPar is not disabled.^FPL_IndicationProvider^4932
E0^6603^Critical^Memory allocation has failed^FPL_IndicationProvider^4957
E0^6604^Critical^Memory could not be locked.^FPL_IndicationProvider^4958
E0^6721^Critical^Memory allocation for firmware has failed^FPL_IndicationProvider^5149
E0^6784^Critical^FW detected an illegal memory configuration using 4GB DIMMs^FPL_IndicationProvider^5154
E0^6789^Warning^SFW component is using SCR RAM space outside of it range.^FPL_IndicationProvider^6858
E0^7017^Error^Uncorrectable ECC error in DIMM^FPL_IndicationProvider^6860
E0^7090^Warning^Windows paging file size or the memory dump target volume is too small.^FPL_IndicationProvider^5249
E0^7119^Warning^One or more of the cells are not configured for Cell-Local Memory (CLM) mode.^FPL_IndicationProvider^5259
E0^7120^Warning^Double DRAM chip sparing events have been invoked.^FPL_IndicationProvider^5260
E0^7121^Warning^A platform error was detected by the firmware/hardware, and corrected by using a spare channel.   ^FPL_IndicationProvider^5261
E0^7127^Warning^A platform error was detected by the firmware/hardware, and corrected by using a spare channel.^FPL_IndicationProvider^5263
E0^7128^Warning^A platform error was detected by the firmware/hardware, and corrected by using a spare channel.^FPL_IndicationProvider^5264
E0^7135^Warning^Duplicate DIMM serial numbers have been detected.^FPL_IndicationProvider^6564
E0^7153^Warning^Double chip sparing has been invoked.^FPL_IndicationProvider^6572
E0^7557^Warning^HP unsupported DIMM(s) has been detected on this partition. ^ ^ 