{"manifest":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"qlgc-qla2xxx-kmp-default-10.02.11.00_k1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.11.00-k1"}],"installation_dependency":{},"name":"SuSE Linux Enterprise Server 15 Service Pack 5 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin","InstallDurationSec":800,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin","InstallDurationSec":800,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-smartarray-9f082dffb4-1.00-4.1.x86_64.rpm","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"0","version":"1.00"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Backplane Expander Firmware","per_device_install_time_seconds":800,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","9.0","8.0"]}],"supported_platforms":true,"supported_products":["U38","U38","U38"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059036.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"1","version":"6.2.26.720"}],"installation_dependency":{},"name":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317","10.0","10.0"]}],"supported_platforms":true,"supported_products":["A41","A48","A43","A47","A43","A40","A42","A46","A43","A42","A42"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055148.exe","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304a57525444"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-9e87eecb3f-HPG3-6.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U50_2.00_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.00 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u50-2.00_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000022b"],"type_of_change":"1","version":"2.00_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U50"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG5"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG5"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG5"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052429.exe","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-5dcf26fa42-HPD2-10.1.x86_64.rpm","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42","452340a5-304f-3030-3430-304a57444b50","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3830-304a57444b56"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059017.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"bnxtroce","version":"228.0.116.0-1OEM.700.1.0.15843807"},{"name":"bnxtnet","version":"228.0.116.0-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059940.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-igb-6.14.16-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"6.14.16-1"},{"name":"kmod-hp-igb-6.14.16-1.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"6.14.16-1"},{"name":"kmod-hp-igb-6.14.16-1.rhel8u6.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"6.14.16-1"}],"installation_dependency":{},"name":"HPE Intel igb Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U54","U40","U41","U32","A42","U58","A55","O43","U56","U50","U58","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","03020101","A40","A56","A46","U58","U46","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b5a595755","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b5a595842","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b5a595843","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3130-3932-304b5a595754","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3330-3834-304b5a595756","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3730-3638-304b5a595841","Version":"HPK5"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Solidigm_P5x20_4IAAHPK5.fwpkg","target_guids":["4d2340a5-304f-3130-3630-304b5a595755","4d2340a5-304f-3330-3230-304b5a595842","4d2340a5-304f-3630-3430-304b5a595843","562340a5-304f-3130-3932-304b5a595754","562340a5-304f-3330-3834-304b5a595756","562340a5-304f-3730-3638-304b5a595841"],"type_of_change":"1","version":"HPK5"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3130-3630-304b5a595755","4d2340a5-304f-3330-3230-304b5a595842","4d2340a5-304f-3630-3430-304b5a595843","562340a5-304f-3130-3932-304b5a595754","562340a5-304f-3330-3834-304b5a595756","562340a5-304f-3730-3638-304b5a595841"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057010.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.15"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Windows (x64) - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["422340a5-3939-4644-4237-342d07f65795"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U30","U34","A43","A43","A40","A42","A43","P89","U46","A42","U46","U41","A42","U31","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp054434.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdc79ba4d"],"type_of_change":"0","version":"1.0.0.1"}],"installation_dependency":{},"name":"HPE QLogic Smart SAN Enablement Kit for Fibre Channel Host Bus Adapter for Microsoft Windows Server 2022 (x86_64)","per_device_install_time_seconds":280,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","SPP","A42","A43","U40","U39","U41","U32","A42","U50","A42","A43","A47","U33","U37","U34","U30","A48","U34","U47","U47","A40","A46","U46","U48","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-a07a420ed1-HPD5-2.1.x86_64.rpm","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.00 (03/06/2024)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.00 (03/06/2024)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.00 (03/06/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U46_2.00_03_06_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"type_of_change":"1","version":"2.00_03-06-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Universal Firmware Package - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U46","U46","FTP","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-18e328f036-HPG8-2.1.x86_64.rpm","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053432.zip","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP053432","version":"HPG4.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU, VK003840GWSRV  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757535256","562340a5-304b-3130-3932-304757535255","562340a5-304b-3030-3936-304757535254","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3234-304757535251"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1655SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3130-3630-30505a575348","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1655SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3330-3230-30505a57534b","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1655SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3030-3830-30505a575346","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1655SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3630-3430-30505a584641","Version":"HPD3"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Samsung_PM165X_GPM1655SAMD3.fwpkg","target_guids":["4d2340a5-304f-3130-3630-30505a575348","4d2340a5-304f-3330-3230-30505a57534b","4d2340a5-304f-3030-3830-30505a575346","4d2340a5-304f-3630-3430-30505a584641"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3130-3630-30505a575348","4d2340a5-304f-3330-3230-30505a57534b","4d2340a5-304f-3030-3830-30505a575346","4d2340a5-304f-3630-3430-30505a584641"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-fe9c474847-HPK3-7.1.x86_64.rpm","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-304b57564d56","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3130-3932-304b57564d54"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055177.exe","target_guids":["562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3234-304757434644","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-30475743464b","562340a5-304b-3130-3932-304757434648","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3234-304757434644"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055209.exe","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWWQB and MB002000JWWQA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052932.exe","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3230-304a45544b43","002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055321.zip","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB","vib_list":[{"name":"CP055321","version":"HPDB.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB4000JEQNL and MB6000JEQNN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-qlgc-qla2xxx-10.02.11.00_k1-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.11.00-k1"}],"installation_dependency":{},"name":"Red Hat Enterprise Linux 8 Update 8 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059707.exe","target_guids":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-a46-3.00_2024_01_26-2.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0"]}],"supported_platforms":false,"supported_products":["A46"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_40_1000-MCX653436A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900348","Version":"20.40.1000"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"20_40_1000-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900348"],"type_of_change":"1","version":"20.40.1000"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b15900348"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","A42","U58","A55","U50","U50","A43","A47","U54","U58","A48","U47","U47","U47","U47","A55","A40","A56","A46","U46","U46","U46","U59","U58"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp054321.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"type_of_change":"1","version":"7.716.3.0"}],"installation_dependency":{},"name":"HPE MR416i-p,MR416i-a, MR216i-p, MR216i-a 64-bit controller driver for Microsoft Windows 2016 edition.","per_device_install_time_seconds":400,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599"]}],"supported_platforms":false,"supported_products":["U30","A43","A43","A42","A42","A43","U46","U46","U61","U32","A42","U60"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058994.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"qedentv","version":"3.71.52.0-1OEM.800.1.0.20613240"},{"name":"qedrntv","version":"3.71.50.0-1OEM.800.1.0.20613240"},{"name":"qedi","version":"2.74.1.0-1OEM.800.1.0.20613240"},{"name":"qedf","version":"2.74.1.0-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U30","U46","O43","U40","U56","U50","U61","U60","A43","A47","02020001","U33","03020102","U37","U39","U36","U34","U30","A48","U34","U47","U47","U47","03020101","A40","A46","U46","U31","U46","U48","U26","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060563.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"0","version":"10.1.18807.8279"}],"installation_dependency":{},"name":"Identifiers for Intel Xeon E-23xx Processor for Microsoft Windows","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U61","U64","U60"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U60_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u60-2.00_2024_02_01-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000023e"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Proliant DL20 Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["FTP","U60"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v3.00 (01/26/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059458.exe","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A43","A43","A43"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG3"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG3"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG3"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-4b4177239b-HPG3-4.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3730-3638-304758434752","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.21"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.21"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.21"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059079.zip","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"type_of_change":"1","version":"1.34.0","vib_list":[{"name":"CP059079","version":"1.34.0.3-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE QLogic NX2 Online Firmware Upgrade Utility for VMware","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U40","U41","U32","U30","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055159.exe","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEQNL and MB6000JEQNN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055345.zip","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG","vib_list":[{"name":"CP055345","version":"HPGG.5-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-304757485255","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","562340a5-304b-3030-3234-304757455a42","4d2340a5-304b-3030-3438-304757455a48","562340a5-304b-3030-3438-304757455a43","4d2340a5-304b-3030-3936-304757455a4b","562340a5-304b-3030-3936-304757455a44"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"16_35_3006-MCX512F-ACH_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30116","Version":"16.35.3006"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"16_35_3006-MCX512F-ACH_Ax_Bx.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101715b30116"],"type_of_change":"1","version":"16.35.3006"}],"installation_dependency":{},"name":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30116"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["U30","A41","A48","U47","A43","A47","A43","U47","U50","A40","A42","A46","U56","A43","U46","A42","U46","U60","U32","A42"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057483.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be","20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c"],"type_of_change":"1","version":"2023.12.01","vib_list":[{"name":"storcli","version":"007.2613.0000.0000-01"}]}],"installation_dependency":{},"name":"HPE MegaRAID Storage Administrator StorCLI for VMware8.0 (For Gen10P and Gen11 Controllers)","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U54","U65","U32","A42","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058339.zip","target_guids":["4d2340a5-3042-3431-3030-304a58554343"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP058339","version":"HPD4.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JXUCC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a58554343"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.2006"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_3006-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.3006"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_3006-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.3006"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp057948.exe","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"type_of_change":"1","version":"1.0.0.13"}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Windows x86_64 platform","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1013159000ef","a6b1a447-382a-5a4f-15b3-101715900257","a6b1a447-382a-5a4f-15b3-101715900255"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A43","A42","A42","A43","U32","A42","U27","U50","U19","U50","U61","A43","A47","02020001","03020101","03020102","P89","P89","U37","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46"]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp059609.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-dl20gen10plus_me-06.00.03.604-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["FTP","U60"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055258.zip","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP055258","version":"HPD5.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EG000300JWBHR Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57424852"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14258919.grp","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.2.589.19"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14258919.grp","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.2.589.19"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14258921.grp","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.2.589.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14258921.grp","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.2.589.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14258921.grp","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.2.589.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14258921.grp","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.2.589.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14258919.grp","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.2.589.19"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14258919.grp","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.2.589.19"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058597.zip","target_guids":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2023.10.01","vib_list":[{"name":"CP058597","version":"2023.10.01.5-7.0.0.15843807"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  7.0","per_device_install_time_seconds":240,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-netxtreme2-7.15.17-7.rhel8u9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"1","version":"7.15.17-7"},{"name":"kmod-netxtreme2-7.15.17-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"1","version":"7.15.17-7"}],"installation_dependency":{},"name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16af103c1933","a6b1a447-382a-5a4f-14e4-16ad103c1917","a6b1a447-382a-5a4f-14e4-16ae103c3382","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","U40","U41","U32","U30","O43","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055137.exe","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWBXQ and MB008000GWBYL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"bnxt_en-kmp-default-1.10.2_k5.14.21_150400.22-228.0.133.0.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"1","version":"1.10.2-228.0.133.0"},{"name":"bnxt_en-kmp-default-1.10.2_k5.14.21_150500.53-228.0.133.0.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"1","version":"1.10.2-228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.3006"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057778.zip","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.7","vib_list":[{"name":"CP057778","version":"1.0.5-7.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (ESXi 7.0) for Mellanox Open Ethernet cards","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U32","A42","U50","U50","U61","A43","A47","U30","A48","U47","U47","U47","U47","U56","A46","U46","U46","U46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060553.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"type_of_change":"0","version":"9.15.1.248"}],"installation_dependency":{},"name":"Matrox G200eH3 Video Controller Driver for Microsoft Windows 64-bit","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-102b-0538159000e4","a6b1a447-382a-5a4f-102b-05381590027f"],"supported_operating_systems":[{"os":"Windows","version":["10.0","10.0","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","H08","U50","H10","U50","I44","H08","U61","U60","A43","A47","I41","U33","I43","I42","U37","U39","U40","U36","U34","U30","U64","A48","U34","U47","U47","U56","A40","A46","H10","U46","U31","H10","U46","U48","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058393.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"type_of_change":"1","version":"1.18.367.0"}],"installation_dependency":{},"name":"Intel i40ea Driver for Windows Server 2022","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A42","U56","A42","H08","H10","U50","H08","U61","A43","A47","U60","A48","U64","U47","U47","U47","A43","A46","H10","U46","H10","U46","H09","U48"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059637.zip","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPDB","vib_list":[{"name":"CP059637","version":"HPDB.4-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055149.exe","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWAYK and MB008000JWAYH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059019.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"1","version":"228.0.121.0"}],"installation_dependency":{},"name":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16c514e41593","a6b1a447-382a-5a4f-14e4-16c514e41592","a6b1a447-382a-5a4f-14e4-16bd14e41593","a6b1a447-382a-5a4f-14e4-16bd14e41592","a6b1a447-382a-5a4f-14e4-16bd14e41595","a6b1a447-382a-5a4f-14e4-16bd14e41594","a6b1a447-382a-5a4f-14e4-16bd14e41597","a6b1a447-382a-5a4f-14e4-16bd14e41596","a6b1a447-382a-5a4f-14e4-16c514e41595","a6b1a447-382a-5a4f-14e4-16c514e41594","a6b1a447-382a-5a4f-14e4-16c514e41597","a6b1a447-382a-5a4f-14e4-16c514e41596","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e416d8","a6b1a447-382a-5a4f-14e4-16dc14e416d6","a6b1a447-382a-5a4f-14e4-16dc14e416d7","a6b1a447-382a-5a4f-14e4-16dc14e41593","a6b1a447-382a-5a4f-14e4-16dc14e41592","a6b1a447-382a-5a4f-14e4-16c114e41593","a6b1a447-382a-5a4f-14e4-16c114e41592","a6b1a447-382a-5a4f-14e4-16c114e41595","a6b1a447-382a-5a4f-14e4-16c114e41594","a6b1a447-382a-5a4f-14e4-16c114e41597","a6b1a447-382a-5a4f-14e4-16c114e41596","a6b1a447-382a-5a4f-14e4-16dc14e41595","a6b1a447-382a-5a4f-14e4-16dc14e41594","a6b1a447-382a-5a4f-14e4-16dc14e41597","a6b1a447-382a-5a4f-14e4-16dc14e41596","a6b1a447-382a-5a4f-14e4-180814e41599","a6b1a447-382a-5a4f-14e4-180814e41598","a6b1a447-382a-5a4f-14e4-180914e41599","a6b1a447-382a-5a4f-14e4-180914e41598","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180614e41751","a6b1a447-382a-5a4f-14e4-180614e41599","a6b1a447-382a-5a4f-14e4-180614e41598","a6b1a447-382a-5a4f-14e4-180714e41599","a6b1a447-382a-5a4f-14e4-180714e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U65","U43","A43","U62","A42","A42","U56","U54","A56","U65","A42","U58","A55","U50","H10","U50","U54","U61","U58","U63","U59","A43","U54","U65","U40","U60","U64","03030201","U47","U47","U47","A43","A56","A46","H10","A55","U46","H10","U46","U48","U63","U58"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770068","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770068","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770069","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770069","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770070","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770070","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770071","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770071","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770073","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770073","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770072","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770072","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770074","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770074","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770077","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770077","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770077","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770078","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770078","Version":"8.65.09"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770078","Version":"8.65.09"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"ql_ah_mbi_open_8.65.09_pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-80f010770068","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-80f010770069","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-80f010770070","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-80f010770071","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-809010770073","a6b1a447-382a-5a4f-1077-80f010770073","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-80f010770072","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-80f010770074","a6b1a447-382a-5a4f-1077-807010770077","a6b1a447-382a-5a4f-1077-809010770077","a6b1a447-382a-5a4f-1077-80f010770077","a6b1a447-382a-5a4f-1077-807010770078","a6b1a447-382a-5a4f-1077-809010770078","a6b1a447-382a-5a4f-1077-80f010770078"],"type_of_change":"1","version":"8.65.09"}],"installation_dependency":{},"name":"Marvell FastLinQ Firmware Package for Arrowhead adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","12.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","U56","H10","U46","A42","U50","U61","A43","A47","U60","A48","U47","U47","U47","A43","A46","H10","U46","H10","U46","U48"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059858.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec74b19684"],"type_of_change":"1","version":"1.2.1.68"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"62.0.28.64","description":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update."}]}]}]},"name":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0655","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-103c-193f159000e4"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0","10.0","10.0.20317"]}],"supported_platforms":false,"supported_products":["U38","U38","A43","A42","A42","A43","U40","U32","A42","U50","I44","U61","U60","A43","A47","I41","U33","I43","I42","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U48","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053553.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6d17a48"],"type_of_change":"1","version":"2.1.230.0"}],"installation_dependency":{},"name":"HPE Intel vxs Driver for Windows Server 2019","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1565159000d1","a6b1a447-382a-5a4f-8086-1565159000d2"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","A40","U33","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-a41-3.00_2024_01_26-2.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-d8000-0130-3.1.x86_64.rpm","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0130"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","12.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPS1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3030-3936-304b584e5844","Version":"HPS1"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPS1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3130-3932-304b584e5a51","Version":"HPS1"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPS1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3330-3834-304b584e5a52","Version":"HPS1"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPS1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3730-3638-304b584e5a54","Version":"HPS1"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPS1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b584e5848","Version":"HPS1"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPS1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b584e5a56","Version":"HPS1"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPS1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58504141","Version":"HPS1"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPS1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58504142","Version":"HPS1"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Micron_7450_M7450ALLHPS1.fwpkg","target_guids":["562340a5-304f-3030-3936-304b584e5844","562340a5-304f-3130-3932-304b584e5a51","562340a5-304f-3330-3834-304b584e5a52","562340a5-304f-3730-3638-304b584e5a54","4d2340a5-304f-3030-3830-304b584e5848","4d2340a5-304f-3130-3630-304b584e5a56","4d2340a5-304f-3330-3230-304b58504141","4d2340a5-304f-3630-3430-304b58504142"],"type_of_change":"1","version":"HPS1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3130-3932-304b584e5a51","562340a5-304f-3330-3834-304b584e5a52","562340a5-304f-3730-3638-304b584e5a54","4d2340a5-304f-3030-3830-304b584e5848","4d2340a5-304f-3130-3630-304b584e5a56","4d2340a5-304f-3330-3230-304b58504141","4d2340a5-304f-3630-3430-304b58504142","562340a5-304f-3030-3936-304b584e5844"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059815.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e6a28ab"],"type_of_change":"1","version":"2024.03.01","vib_list":[{"name":"amsd","version":"701.11.10.0.4-1OEM.701.0.0.16850804"}]}],"installation_dependency":{},"name":"HPE Agentless Management Bundle Smart Component on ESXi for Gen10 and Gen10 Plus Servers","per_device_install_time_seconds":200,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U46","U50","I44","U61","U60","A43","A47","I41","U65","U33","I43","I42","U37","U64","U34","U30","A48","U34","U47","U47","U56","A40","A46","U46","U31","U46","U48","U39","U31"]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-3052-3030-3438-304b584e5845","Version":"HPK2"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-3052-3030-3936-304b584e5a55","Version":"HPK2"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Micron_7450_M7450ALLHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-3053-3130-3932-304b584e5846","Version":"HPK2"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Micron_7450_M7450ALLHPK2.fwpkg","target_guids":["562340a5-3052-3030-3438-304b584e5845","562340a5-3052-3030-3936-304b584e5a55","562340a5-3053-3130-3932-304b584e5846"],"type_of_change":"1","version":"HPK2"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - VR000480KXNXE,VR000960KXNZU and VS001920KXNXF","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-3052-3030-3438-304b584e5845","562340a5-3052-3030-3936-304b584e5a55","562340a5-3053-3130-3932-304b584e5846"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057758.zip","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP057758","version":"HPD5.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3030-3936-30525a575550","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3030-3936-30525a575551","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3130-3932-30525a575552","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3130-3932-30525a575556","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3330-3834-30525a575554","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3330-3834-30525a575641","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3730-3638-30525a575555","Version":"HPD1"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","target_guids":["562340a5-304f-3030-3936-30525a575550","562340a5-304f-3030-3936-30525a575551","562340a5-304f-3130-3932-30525a575552","562340a5-304f-3130-3932-30525a575556","562340a5-304f-3330-3834-30525a575554","562340a5-304f-3330-3834-30525a575641","562340a5-304f-3730-3638-30525a575555"],"type_of_change":"1","version":"HPD1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-30525a575550","562340a5-304f-3030-3936-30525a575551","562340a5-304f-3130-3932-30525a575552","562340a5-304f-3130-3932-30525a575556","562340a5-304f-3330-3834-30525a575554","562340a5-304f-3330-3834-30525a575641","562340a5-304f-3730-3638-30525a575555"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.17600.18999","10.0.14393.17599","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U44_3.00_02_01_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.5","6.7","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U44"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020907.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.09.07"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020907.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.09.07"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020205.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.02.05"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020205.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.02.05"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020205.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.02.05"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020205.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.02.05"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020907.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.09.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020907.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.09.07"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-fc-qlogic-2023.10.01-2.2.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2023.10.01"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.0.1-3","description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active"}]}]}]},"name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Linux (x86_64)","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U64_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.00 (02/01/2024)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U64_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.00 (02/01/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U64_2.00_02_01_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U64","FTP"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-c566d63ca0-HPG7-2.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG7"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPDA.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053443.zip","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPDA","vib_list":[{"name":"CP053443","version":"HPDA.6-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JWXKH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304a57584b48"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053396.zip","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP053396","version":"HPG1.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304757525443"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM2 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_UBM2_1.20_E.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901502000000","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_UBM2_1.20_E.fwpkg","target_guids":["9675b54e-1c96-44c3-a7a1-901502000000"],"type_of_change":"1","version":"1.20"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4650","description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4650","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Firmware Package - UBM2 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 Servers","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","8.0","15.0","10.0.20317","8.0","9.0","7.0","12.0","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":["U61","A42","A43","U46","A55","A43","A55","A56","A56","U58","A43","U54","U46","U54","U46","I44","U60","U63","U50"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058577.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc02887d0"],"type_of_change":"1","version":"6.30.8.0"}],"installation_dependency":{},"name":"Smart Storage Administrator (SSA) for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U27","P95","A43","A43","U54","U40","U41","U12","U13","U32","Carbondale14","U14","U14","U25","Carbondale14","U19","A47","U33","U54","I45","A48","O42","U58","U39","U38","U38","U38","U38","U38","U65","A42","P85","A55","U23","U21","O43","P89","I44","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U48","U31","U31","A42","U14","U13","U24","U40","U18","U18","I43","I42","U37","U18","U34","U57","U20","U20","A40","U62","U63","U17","P86","A42","I40","U65","A46","U22","U50","U54","U63","A43","U39","U40","U36","U58","P92","U34","U47","U47","U58","Carbondale14","U46","U46"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059946.exe","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U30","A41","U45","U34","U44","U43","U38","U38","I41","A40","U33","U37","U39","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-70e3962f98-HPG6-12.1.x86_64.rpm","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB2000GFEMH and MB4000GFEMK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG5"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055326.zip","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG5","vib_list":[{"name":"CP055326","version":"HPG5.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GVYZB and MB4000GVYZA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304756595a41","002340a5-4d00-3642-3030-304756595a42"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"IEGen10Plus_1.0.0.22.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"IEGen10Plus_1.0.0.22.fwpkg","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000303"],"type_of_change":"1","version":"1.0.0.22"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0"]}],"supported_platforms":true,"supported_products":["U46","U47","U47","U56","H10","U50","U46","H10","U46","I44","H10"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055348.zip","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP055348","version":"HPG3.6-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit-14.2.589.11-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"0","version":"14.2.589.11"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit-14.2.589.11-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"0","version":"14.2.589.11"}],"installation_dependency":{},"name":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters for SuSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-i40e-2.23.17-1.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.23.17-1"},{"name":"kmod-hp-i40e-2.23.17-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.23.17-1"},{"name":"kmod-hp-i40e-2.23.17-1.rhel8u6.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.23.17-1"}],"installation_dependency":{},"name":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","A42","A43","U40","U41","U32","A42","O43","U56","U50","U61","U60","A43","A47","02020001","U33","03020102","U37","U36","U34","U30","U64","A48","U34","U47","U47","U47","03020101","A40","A46","U46","U39","U46","U48","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"hp-i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"1","version":"2.23.17-1"},{"name":"hp-i40e-kmp-default-2.23.17_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"1","version":"2.23.17-1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"name":"Linux","value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.3","description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"name":"Linux","value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.3","description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component"}]}]}]},"name":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","A42","A43","U40","U41","U32","A42","O43","U56","U50","U61","U60","A43","A47","02020001","U33","03020102","U37","U36","U34","U30","U64","A48","U34","U47","U47","U47","03020101","A40","A46","U46","U39","U46","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd61cbbea"],"type_of_change":"0","version":"3.3-3"}],"installation_dependency":{},"name":"HPE QLogic Smart SAN enablement kit for Linux","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058383.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"type_of_change":"1","version":"1.18.367.0"}],"installation_dependency":{},"name":"HPE Intel i40eb Driver for Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD2"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059877.exe","target_guids":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB018000JXMTH and MB020000JXMTP Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u33-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U33"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP052251.zip","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27","vib_list":[{"name":"CP052251","version":"1.27.2-7.0.0.15843807"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW","per_device_install_time_seconds":240,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A46","U47","U47"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-ae6b41e855-HPD8-4.1.x86_64.rpm","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055312.zip","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP055312","version":"HPD3.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057489.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"type_of_change":"1","version":"7.2613.0.0"}],"installation_dependency":{},"name":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":true,"supported_products":["A43","A42","A42","A43","U54","U65","U32","A42","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-46fc43ab26-HPD4-12.1.x86_64.rpm","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFDSL and MB4000JFDSN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.28.41"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059040.zip","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"1","version":"1.37.0","vib_list":[{"name":"CP059040","version":"1.37.0.8-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"}]}]}]},"name":"HPE Broadcom NX1 Online Firmware Upgrade Utility VMware for HPE ProLiant Gen10 server series Only.","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","U36","02020001","U33","03020102","U37","U39","U40","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-24fe569b72-HPD5-5.1.x86_64.rpm","target_guids":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059540.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec948d20a3"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"ilo","version":"700.10.8.2.2-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE iLO Driver Bundle Smart Component for ESXi 7.0","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":["U54","A41","U17","U44","U43","U38","U38","A43","A42","A42","A43","U45","A56","U40","U41","U32","A42","U65","U58","U46","P85","A55","U47","U50","U56","I44","I39","U58","U54","U61","U60","U63","A43","A47","I41","I37","U54","U33","P89","P89","U37","U64","I45","U62","U65","U34","U30","A48","U57","U34","U59","U47","I36","I43","A40","A56","A46","I42","U46","U39","U46","A55","U48","U63","U58","U31","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059506.exe","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A41"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP052070.zip","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.0","vib_list":[{"name":"CP052070","version":"1.0.0-8.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","A40","U19","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055259.zip","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP055259","version":"HPD4.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWFUV and EG001200JWFVA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a57465641","452340a5-3047-3030-3630-304a57465556"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP056237.zip","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP056237","version":"HPG3.1-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp060110.exe","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"hp-ixgbevf-kmp-default-4.18.7_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"1","version":"4.18.7-1"},{"name":"hp-ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"1","version":"4.18.7-1"}],"installation_dependency":{},"name":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR416i-a_Gen10P_52.26.3-5379_A.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.26.3-5379"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_MR416i-a_Gen10P_52.26.3-5379_A.fwpkg","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032a"],"type_of_change":"1","version":"52.26.3-5379"}],"installation_dependency":{},"name":"Firmware Package - HPE MR416i-a Gen10 Plus Tri Mode Controller","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e21590032a"],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","10.0.14393.17599","8.0","15.0","12.0","10.0.20317","9.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U46","A43","A43","A42","A42","U46","U46","U61","U60"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-db687966b4-HPG4-8.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757535256","562340a5-304b-3130-3932-304757535255","562340a5-304b-3030-3936-304757535254","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3234-304757535251"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053414.zip","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP053414","version":"HPG6.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-3047464a5445"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056805.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","20a6e8e4-bf33-4c71-a6bf-d9ec6164afab"],"type_of_change":"1","version":"2023.09.00","vib_list":[{"name":"ixgben","version":"1.15.1.0-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"HPE Intel ixgben Driver for VMware vSphere 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["U30","A41","U45","U34","U44","U43","U38","U38","U39","02020001","A40","U33","03020102","03020101","U37","U41","U31","U32","U36","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-9475583fb5-HPG1-2.1.x86_64.rpm","target_guids":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-qlgc-qla2xxx-10.02.11.00_k1-1.rhel8u9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.11.00-k1"}],"installation_dependency":{},"name":"Red Hat Enterprise Linux 8 Update 9 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-71af849f3b-HPD3-12.1.x86_64.rpm","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-304f-3830-304a45465046","002340a5-4d00-314f-3630-304a45465043","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-304f-3230-304a45464e56","002340a5-4500-304f-3430-304a45465045","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3830-304a45465042"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK7"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK7"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK7"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-3815d4b024-GPK7-2.1.x86_64.rpm","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK7"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","12.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"sut-5.0.0-13.linux.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"type_of_change":"1","version":"5.0.0.0"}],"installation_dependency":{},"name":"Integrated Smart Update Tools for Linux x64","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","SPP","A42","A43","A40","U40","U39","U41","U32","A42","U65","U58","U46","A55","U56","U50","I44","U58","U54","U61","U60","U63","A42","A43","A47","U33","I43","I42","U37","U62","I45","U34","U30","U64","A48","U34","U59","U47","U47","A55","A56","A56","A46","U46","U46","U65","U48","U63","U58","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058251.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"type_of_change":"1","version":"7.13.206.0"}],"installation_dependency":{},"name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ad103c2231"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U40","U41","U32","U30","O43","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"libbnxt_re-228.0.133.0-rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"1","version":"228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 7.","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD8"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD8"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP054146.zip","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP054146","version":"HPD8.1-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP052260.zip","target_guids":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"type_of_change":"1","version":"0.39","vib_list":[{"name":"CP052260","version":"0.39.4-7.0.0.15843807"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":true,"supported_products":["U50"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055349.zip","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP055349","version":"HPG3.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-30475753584c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-netxtreme2-7.15.17-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"1","version":"7.15.17-7"},{"name":"kmod-netxtreme2-7.15.17-7.rhel9u3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"1","version":"7.15.17-7"}],"installation_dependency":{},"name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16af103c1933","a6b1a447-382a-5a4f-14e4-16ad103c1917","a6b1a447-382a-5a4f-14e4-16ae103c3382","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","U40","U41","U32","U30","O43","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDA"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDA"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDA"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDA"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDA"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-3d97759111-HPDA-2.1.x86_64.rpm","target_guids":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"type_of_change":"1","version":"HPDA"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053404.zip","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP053404","version":"HPG2.2-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304757554441"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052336.exe","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-3047464a5445"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056804.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"type_of_change":"1","version":"2023.09.00","vib_list":[{"name":"igbn","version":"1.11.2.0-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"HPE Intel igbn Driver for VMware vSphere 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U54","U40","U41","U32","A42","U58","A55","O43","U56","U50","U58","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","03020101","A40","A56","A46","U58","U46","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-i40e-2.23.17-1.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.23.17-1"},{"name":"kmod-hp-i40e-2.23.17-1.rhel9u0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.23.17-1"},{"name":"kmod-hp-i40e-2.23.17-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.23.17-1"}],"installation_dependency":{},"name":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","A42","A43","U40","U41","U32","A42","O43","U56","U50","U61","U60","A43","A47","02020001","U33","03020102","U37","U36","U34","U30","U64","A48","U34","U47","U47","U47","03020101","A40","A46","U46","U39","U46","U48","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055168.exe","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57554442"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp051152.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbf0a9496"],"type_of_change":"1","version":"2022.09.01","vib_list":[{"name":"fc-enablement","version":"800.3.9.0.30-1OEM.800.1.0.20172892"}]}],"installation_dependency":{},"name":"HPE Fiber Channel and Storage Enablement Bundle Smart Component for ESXi 8.0","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U54","A56","U40","U41","U32","A42","U65","U58","U46","A55","U50","U56","U50","I44","I45","U58","U54","U61","U60","U63","A43","A47","I41","U65","U54","U33","I43","I42","U37","U64","U62","U65","U34","U30","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U31","U46","U48","U63","U58","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058581.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"type_of_change":"1","version":"2024.04.01","vib_list":[{"name":"ssacli2","version":"6.30.8.0-7.0.0.15525992.oem"}]}],"installation_dependency":{},"name":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 7.0 for Gen10/Gen10 Plus/Gen11 Controllers","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["U27","P95","A43","A43","U54","U40","U41","U12","U13","U32","Carbondale14","U14","U14","U25","Carbondale14","U19","A47","U33","U54","I45","A48","O42","U58","U38","U38","U38","U38","U38","U65","A42","P85","A55","U23","U21","P89","I44","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U48","A41","A42","U17","U13","U24","U14","U51","U18","U18","I43","I42","U37","U18","U34","U57","U20","U20","A40","U47","U62","U63","U45","P86","U44","U43","A48","A42","I40","U65","A46","U50","U22","U50","U54","U63","A43","U39","U40","U40","U58","P92","U34","U47","U47","U47","U58","U46","Carbondale14","U46","U46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"mft-4.26.1-3.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"0","version":"4.26.1-3"},{"name":"kernel-mft-mlnx-kmp-default-4.26.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"0","version":"4.26.1-3"}],"installation_dependency":{},"name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP5 (AMD64/EM64T)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U43","U38","U38","A43","A42","A42","A43","U45","U40","U39","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","U37","U36","U34","U30","A48","U34","03030201","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-qlgc-qla2xxx-10.02.11.00_k1-1.rhel9u3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.11.00-k1"}],"installation_dependency":{},"name":"Red Hat Enterprise Linux 9 Update 3 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"amsd-3.5.0-1803.25.rhel8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"0","version":"3.5.0"}],"installation_dependency":{},"name":"Agentless Management Service (iLO5, iLO 6) for Red Hat Enterprise Linux 8 Server","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U54","A56","U40","U41","U32","A42","U65","U58","A55","U50","A45","I44","U58","U54","U61","U60","U63","A43","A47","I41","U33","I43","I42","U37","U24","I45","U34","U30","U64","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U46","U46","U65","U62","U63","U58","U54"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.2.589.21-1//firmware//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.2.589.19"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.2.589.21-1//firmware//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.2.589.19"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.2.589.21-1//firmware//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.2.589.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.2.589.21-1//firmware//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.2.589.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.2.589.21-1//firmware//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.2.589.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.2.589.21-1//firmware//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.2.589.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.2.589.21-1//firmware//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.2.589.19"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.2.589.21-1//firmware//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.2.589.19"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp058600.exe","target_guids":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2023.10.01"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2019/2022 x64","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_33_1048-872726-B21_Ax_Bx-UEFI-14.26.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.33.1048"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_33_1048-879482-B21_Ax-UEFI-14.26.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.33.1048"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053859.zip","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.0","vib_list":[{"name":"CP053859","version":"1.0.0-8.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (ESXi 8.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["U38","U38","A43","A42","A42","A43","U40","U32","A42","U50","U50","U61","A43","A47","U37","A48","U47","U47","U47","U47","U56","A46","U46","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055264.zip","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP055264","version":"HPD6.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055690.zip","target_guids":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP055690","version":"HPG1.1-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives.","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055266.zip","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP055266","version":"HPD8.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JFHMH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3830-304a46484d48"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U61_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u61-2.00_2024_02_01-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000023c"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U61","FTP"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U45_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0"]}],"supported_platforms":false,"supported_products":["U45"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06154-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.40.1000"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06250-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.40.1000"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06251-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.40.1000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP060193.zip","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP060193","version":"1.0.2-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","03020102","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.21"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.21"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.21"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059078.exe","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"type_of_change":"1","version":"5.3.6.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.13.165.0","description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"supported_operating_systems":[{"os":"Windows","version":["10.0","10.0","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U40","U41","U32","U30","O43","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-9196d4f720-HPGG-6.1.x86_64.rpm","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43","4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-bnxt_en-1.10.2-228.0.133.0.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"1","version":"1.10.2-228.0.133.0"},{"name":"kmod-bnxt_en-1.10.2-228.0.133.0.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"1","version":"1.10.2-228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"libbnxt_re-228.0.133.0-rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"1","version":"228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 8.","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK7"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK7"},{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK7"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-2af7385a1e-HPK7-2.1.x86_64.rpm","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154","4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"1","version":"HPK7"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KWZQR, VO003840KWZQT, MO001600KWZQP and MO003200KWZQQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3330-3834-304b575a5154","562340a5-304f-3130-3932-304b575a5152","4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp053316.exe","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.0.12"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on Windows x86_64 platform","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1"],"supported_operating_systems":[{"os":"Windows","version":["6.2","6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","A40","U19","U41","U31","U32","U31","U34"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"228.1.111000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"228.1.111000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"228.1.111000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"228.1.111000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"228.1.111000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059025.zip","target_guids":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"type_of_change":"1","version":"5.21.0","vib_list":[{"name":"CP059025","version":"5.21.0.2-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]}]}]},"name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["A41","03030201","02020001","A40","03020102","03020101"]},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.03"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.03"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.03"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp060262.exe","target_guids":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"1","version":"3.03"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3307159000e4"],"supported_operating_systems":[{"os":"Windows","version":["10.0","10.0","6.1","6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","U38","A43","U38","A42","A43","U40","U41","U32","A42","H08","O43","U40","U51","U50","A45","I44","H08","U61","U60","U39","A42","A43","A47","I41","H10","U33","H09","I43","I42","U37","U24","U38","U40","U36","U34","U30","U64","A48","U34","U47","U47","U47","U47","U56","A40","A46","H10","U46","U39","H10","U46","U48","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056787.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"1","version":"2023.10.00","vib_list":[{"name":"ixgben","version":"1.15.1.0-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE Intel ixgben Driver for VMware vSphere 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["U30","A41","U45","U34","U44","U43","U38","U38","U39","02020001","A40","U33","03020102","03020101","U37","U41","U31","U32","U36","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-abd133f0de-HPG1-2.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_2CQDA2_O_SEC_4p30_PLDMoMCTP_8001AF25.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"4.30"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_E810_2CQDA2_O_SEC_4p30_PLDMoMCTP_8001AF25.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-15928086000e"],"type_of_change":"1","version":"4.30"}],"installation_dependency":{},"name":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-15928086000e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","U65","H10","H08","A55","A42","U50","H08","U54","U61","U58","U63","A43","A47","U54","U60","A48","U57","U59","U47","U47","A43","A56","A56","U58","H10","U46","H10","U46","H09","U62","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD2"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-020fc874ad-HPD2-1.1.x86_64.rpm","target_guids":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-faf39e0ff7-HPD9-6.1.x86_64.rpm","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8a2c06af48-HPD6-13.1.x86_64.rpm","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JEHMD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3830-304a45484d44"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200 1p OSFP MCX75310AAS Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"28_40_1000-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30074","Version":"28.40.1000"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"28_40_1000-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-102115b30074"],"type_of_change":"1","version":"28.40.1000"}],"installation_dependency":{},"name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-102115b30074"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U54","A42","U58","A55","U50","U50","U63","A43","A47","U54","U58","A48","U47","U47","U47","U47","A55","A56","A56","A46","U46","U46","U46","U59","U58"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp053227.exe","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.0.6"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (Windows x64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"supported_operating_systems":[{"os":"Windows","version":["6.2","6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U38","U38","A43","A42","A42","A43","U40","U39","U32","A42","U50","U50","U61","A43","A47","U37","U34","A48","U34","U47","U47","U47","U47","U56","A46","U46","U46","U46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059091.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"23.10.26252.0"}],"installation_dependency":{},"name":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101815b30117","a6b1a447-382a-5a4f-15b3-101e15b30040","a6b1a447-382a-5a4f-15b3-101e15b30042","a6b1a447-382a-5a4f-15b3-101615b30102","a6b1a447-382a-5a4f-15b3-101615b30047","a6b1a447-382a-5a4f-15b3-101815b30116","a6b1a447-382a-5a4f-15b3-101815b30052","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101e15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101e15b30007"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U65","A43","A42","A42","U56","U54","A56","U65","A42","A46","A55","H10","U50","U54","U61","U58","U63","A43","A47","U54","U62","U60","U57","U63","03030201","U47","U47","U47","A43","A56","U58","H10","A55","U46","H10","U46","U48","U59","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK7"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK7"},{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK7"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059262.zip","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154","4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"1","version":"HPK7","vib_list":[{"name":"CP059262","version":"HPK7.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi  - VO001920KWZQR, VO003840KWZQT, MO001600KWZQP and MO003200KWZQQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3330-3834-304b575a5154","562340a5-304f-3130-3932-304b575a5152","4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-35fd24601f-HPD5-2.1.x86_64.rpm","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058385.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","20a6e8e4-bf33-4c71-a6bf-d9ec09108524"],"type_of_change":"1","version":"2023.10.00","vib_list":[{"name":"i40en","version":"2.6.1.0-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"HPE Intel i40en Driver for VMware vSphere 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U44","U43","U38","U38","A42","A43","U41","U32","A42","U56","U61","U60","A43","A47","02020001","U33","03020102","U37","U64","U36","U34","U30","A48","U34","U47","U47","03020101","A40","A46","U46","U46","U48","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058392.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"type_of_change":"1","version":"1.18.367.0"}],"installation_dependency":{},"name":"Intel i40ea Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A42","U56","A42","H08","H10","U50","H08","U61","A43","A47","U60","A48","U64","U47","U47","U47","A43","A46","H10","U46","H10","U46","H09","U48"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK77H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK77H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK77H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK77H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK77H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK77H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK77H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK77H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK77H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK77H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059794.exe","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"type_of_change":"1","version":"MPK77H5Q"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-0 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-3948e450274f"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.14393.17599","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.10 (02/22/2024)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.10 (02/22/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u31-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","11.0","6.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-41cdb1c9da-HPG2-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWUDA Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304757554441"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059015.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"1","version":"228.0.121.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c1159016d7","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A41","U44","U43","U38","U38","03020101","U40","U41","U32","U30","O43","02020001","U33","03020102","U37","U39","U36","U34","U30","U34","A40","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057484.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba","20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd"],"type_of_change":"1","version":"2023.12.01","vib_list":[{"name":"lsi-mr3","version":"7.726.02.00-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"HPE MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p Gen10P and Gen11 controller (64-bit) Driver for vSphere 8.0","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U54","U65","U32","A42","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"MicroserverGen10PlusSPS_05.01.04.913.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.913"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"MicroserverGen10PlusSPS_05.01.04.913.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.913"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0"]}],"supported_platforms":true,"supported_products":["U48"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.28.41"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059041.exe","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"1","version":"5.4.0.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NX1 1Gb Driver is required and should be already active"}]}]}]},"name":"HPE Broadcom NX1 Online Firmware Upgrade Utility Windows Server x64 Editions for HPE ProLiant Gen10 server series Only","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","U36","02020001","U33","03020102","U37","U39","U40","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"qlgc-qla2xxx-kmp-default-10.02.11.00_k1_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.11.00-k1"}],"installation_dependency":{},"name":"SuSE Linux Enterprise Server 15 Service Pack 4 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-tg3-3.139k-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"1","version":"3.139k-1"},{"name":"kmod-tg3-3.139k-1.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"1","version":"3.139k-1"}],"installation_dependency":{},"name":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U65","U58","A55","U50","U40","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U56","U34","U47","U47","U47","03020101","A40","A56","A46","U65","A55","U46","U39","U46","U48","U63","U58","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.rhel8u9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"23.10-1.1.9.1"},{"name":"kmod-mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.rhel8u9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"23.10-1.1.9.1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"name":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ConnectX-4, ConnectX-5 and ConnectX-6 Driver for Red Hat Enterprise Linux 8 Update 9 (x86_64)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U65","U43","U38","U38","A43","U65","A42","A42","A43","U45","A56","U40","U39","U41","U32","A42","U58","U25","A55","U21","U50","U56","U50","U54","U61","U58","U63","U59","A43","A47","02020001","U54","P89","P89","U37","U36","U34","U30","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U46","U54","U46","U46","A55","U62","U63","U58","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052930.exe","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWFVC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3830-304a57465643"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3429.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3429.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3429.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3429.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3429.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3429.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058408.zip","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"1","version":"3.22.0","vib_list":[{"name":"CP058408","version":"3.22.0.6-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"8.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"name":"Intel Online Firmware Upgrade Utility for VMware ","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["U65","A42","A55","03020101","U54","U65","A42","U58","A55","U50","U58","U54","U61","U57","U63","U59","A43","A47","02020001","03020102","U54","U64","A42","U62","U60","A48","03030201","U47","U47","U56","A56","A56","A46","U46","U46","U46","U48","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK77H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK77H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK77H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK77H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK77H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK77H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK77H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK77H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK77H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK77H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059793.zip","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17"],"type_of_change":"1","version":"MPK77H5Q","vib_list":[{"name":"CP059793","version":"MPK77H5Q.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3936-304894dc03d2"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX6314 10/25GbE 2p SFP28 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"26_39_1002-MCX631432AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30007","Version":"26.39.1002"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"26_39_1002-MCX631432AS-ADA_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"type_of_change":"1","version":"26.39.1002"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","U65","A42","U58","A55","U50","U50","U54","U61","U57","U63","A43","A47","U54","U58","A48","U63","U47","U47","U47","U47","U56","A40","A56","A46","U46","A55","U46","U46","U62","U59","U58"]},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051643.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053640.exe","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000303"],"type_of_change":"1","version":"1.0.0.22"}],"installation_dependency":{},"name":"Online ROM Flash for Windows x64 -  HPE Gen10 Plus Innovation Engine Firmware  for HPE Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0","10.0","10.0.20317"]}],"supported_platforms":true,"supported_products":["U47","U47","U56","H10","U50","U46","H10","U46","I44","H10"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060551.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece0b66b06"],"type_of_change":"0","version":"3.0.2.0"}],"installation_dependency":{},"name":"HPE Non-Volatile Memory Drivers for Microsoft Windows Server 2016","per_device_install_time_seconds":60,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599"]}],"supported_platforms":false,"supported_products":["U30","U34","U50","I42","I41","I43","P89","P89","U46","U46","I44","U32","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056772.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"type_of_change":"1","version":"12.18.16.0"}],"installation_dependency":{},"name":"HPE Intel E1R Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-6b7ce3da0e-HPG2-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052982.exe","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053939.zip","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP053939","version":"HPD8.1-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"A46_3.00_01_26_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","7.0"]}],"supported_platforms":false,"supported_products":["A46"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.00 (02/01/2024)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.00 (02/01/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u48-3.00_2024_02_01-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus (U48) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":["U48"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD2"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053344.zip","target_guids":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP053344","version":"HPD2.4-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB006000JYDNF and MB008000JYDPC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053380.zip","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP053380","version":"HPG6.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055147.exe","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304757525443"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059320.zip","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP059320","version":"HPD9.7-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWJRQ and MB006000JWJRP  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"A41_3.00_01_26_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.5","6.7","7.0","8.0"]}],"supported_platforms":false,"supported_products":["A41"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7725Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7725Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7725Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7725Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7725Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7725Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7725Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7725Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7725Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7725Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059790.zip","target_guids":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"type_of_change":"1","version":"MPK7725Q","vib_list":[{"name":"CP059790","version":"MPK7725Q.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG4"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG4"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG4"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053599.exe","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-kernel-mft-mlnx-4.26.1-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"0","version":"4.26.1-3"},{"name":"mft-4.26.1-3.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"0","version":"4.26.1-3"}],"installation_dependency":{},"name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 8 Update 8 (x86_64)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U43","U38","U38","A43","A42","A42","A43","U45","U40","U39","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","U37","U36","U34","U30","A48","U34","03030201","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-f42438de3d-HPG3-11.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3234-304757434644","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-30475743464b","562340a5-304b-3130-3932-304757434648","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3234-304757434644"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u38-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U38","U38","U38","U38","U38"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059092.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"23.10.26252.0"}],"installation_dependency":{},"name":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159000d3","a6b1a447-382a-5a4f-15b3-1016159000d4","a6b1a447-382a-5a4f-15b3-101815900246"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","P89","P89","U37","U39","U40","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41598","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41598","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41598","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41599","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41599","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41599","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-175014e4159a","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180214e4159a","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180514e4159a","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-175014e4159b","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180214e4159b","Version":"228.1.111"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180514e4159b","Version":"228.1.111"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"bcm228.1.111.0_Thor.pup.fwpkg","target_guids":["a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-175014e4159a","a6b1a447-382a-5a4f-14e4-180214e4159a","a6b1a447-382a-5a4f-14e4-180514e4159a","a6b1a447-382a-5a4f-14e4-175014e4159b","a6b1a447-382a-5a4f-14e4-180214e4159b","a6b1a447-382a-5a4f-14e4-180514e4159b"],"type_of_change":"1","version":"228.1.111.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107","description":"HPE Broadcom Firmware version 226.1.107 or greater is required and should be already active"}]}]}]},"name":"Broadcom Firmware Package for BCM5750x adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","12.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","U43","A43","A42","A42","U56","U54","U65","A42","U58","U46","A55","U50","H10","U50","U54","U61","U58","U63","U59","A43","U54","U62","U60","U65","U47","U47","U47","A43","A56","A56","A46","H10","A55","U46","H10","U46","U48","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-2c27a7a9a4-HPD2-6.1.x86_64.rpm","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a574b4755"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-adb3ab8147-HPD8-4.1.x86_64.rpm","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.00 (03/06/2024)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.00 (03/06/2024)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.00 (03/06/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u46-2.00_2024_03_06-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"type_of_change":"1","version":"2.00_03-06-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U46","FTP","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055151.exe","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-d7af557f47-HPD4-7.1.x86_64.rpm","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - MB002000JWFVN and MB004000JWFVP Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-e0171a2936-HPG4-1.1.x86_64.rpm","target_guids":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b45e49679c-HPK4-10.1.x86_64.rpm","target_guids":["562340a5-304b-3130-3932-304b57445548","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3430-304b5744554b"],"type_of_change":"1","version":"HPK4"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64)  - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3030-3430-304b5744554b","4d2340a5-304b-3030-3830-304b5744554c","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3438-304b57445545","562340a5-304b-3030-3936-304b57445546","562340a5-304b-3130-3932-304b57445548"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-smartarray-1f19a4a64d-5.15-3.1.x86_64.rpm","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.15"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["422340a5-3939-4644-4237-342d07f65795"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U30","U34","A43","A43","A40","A42","A43","P89","U46","A42","U46","U41","A42","U31","U34"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U47_2.00_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.00 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U47_2.00_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000227"],"type_of_change":"1","version":"2.00_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","7.0"]}],"supported_platforms":false,"supported_products":["U47","U47","FTP"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"elx-lpfc-kmp-default-14.2.589.21_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"14.2.589.21"}],"installation_dependency":{},"name":"SuSE Linux Enterprise Server 15 Service Pack 4 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR416i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.26.3.5379"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP060395.zip","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032a"],"type_of_change":"2","version":"52.26.3.5379","vib_list":[{"name":"CP060395","version":"52.26.3.5379.8-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Controller Firmware Flash for ESXi7.0 and 8.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e21590032a"],"supported_operating_systems":[{"os":"VMware","version":["8.0","7.0"]}],"supported_platforms":false,"supported_products":["U30","A43","A43","A42","A42","U46","SPP","U46","U61","U32","U60"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059518.exe","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U39","U39"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055172.exe","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-304f-3830-304a45465046","002340a5-4d00-314f-3630-304a45465043","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-304f-3230-304a45464e56","002340a5-4500-304f-3430-304a45465045","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3830-304a45465042"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"libbnxt_re-228.0.133.0-sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"1","version":"228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP4","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053095.exe","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3130-3932-3047574a5048","4d2340a5-304b-3030-3234-3047574b564b","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3330-3834-3047574a504b","4d2340a5-304b-3030-3438-3047574a504e","562340a5-304b-3030-3438-3047574a5045","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3030-3936-3047574a5046"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056440.exe","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304b-3030-3438-304759434e54","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304b-3030-3936-304759434e50","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304b-3130-3932-304759434e46","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304b-3330-3834-304759434e51","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304b-3030-3234-304759434e55","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304b-3030-3438-304759434e48","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304b-3030-3936-304759434e4b","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304b-3130-3932-304759434e4c","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304b-3330-3834-304759434e4e","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304b-3730-3638-304759434e45","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-3052-3030-3234-304758505154","Version":"HPG3"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Solidigm_S4X20_4IYYHPG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-3052-3030-3438-304758505155","Version":"HPG3"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Solidigm_S4X20_4IYYHPG3.fwpkg","target_guids":["4d2340a5-304b-3030-3438-304759434e54","4d2340a5-304b-3030-3936-304759434e50","4d2340a5-304b-3130-3932-304759434e46","4d2340a5-304b-3330-3834-304759434e51","562340a5-304b-3030-3234-304759434e55","562340a5-304b-3030-3438-304759434e48","562340a5-304b-3030-3936-304759434e4b","562340a5-304b-3130-3932-304759434e4c","562340a5-304b-3330-3834-304759434e4e","562340a5-304b-3730-3638-304759434e45","562340a5-3052-3030-3234-304758505154","562340a5-3052-3030-3438-304758505155"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3030-3438-304759434e54","4d2340a5-304b-3030-3936-304759434e50","4d2340a5-304b-3130-3932-304759434e46","4d2340a5-304b-3330-3834-304759434e51","562340a5-304b-3030-3234-304759434e55","562340a5-304b-3030-3438-304759434e48","562340a5-304b-3030-3936-304759434e4b","562340a5-304b-3130-3932-304759434e4c","562340a5-304b-3330-3834-304759434e4e","562340a5-304b-3730-3638-304759434e45","562340a5-3052-3030-3234-304758505154","562340a5-3052-3030-3438-304758505155"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK7"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK7"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK7"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK7"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK7"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059369.exe","target_guids":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"type_of_change":"1","version":"GPK7"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c31355433"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059641.exe","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDA"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDA"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDA"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDA"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055734.exe","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"type_of_change":"1","version":"HPDA"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-ixgbe-5.19.6-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"1","version":"5.19.6-1"},{"name":"kmod-hp-ixgbe-5.19.6-1.rhel8u6.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"1","version":"5.19.6-1"},{"name":"kmod-hp-ixgbe-5.19.6-1.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"1","version":"5.19.6-1"}],"installation_dependency":{},"name":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-481c8ea9a7-HPD7-7.1.x86_64.rpm","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"1","version":"HPD7"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) -  EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314f-3630-304a56595052","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4500-304b-3830-304a5659504e"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060560.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"1","version":"10.1.19006.8299"}],"installation_dependency":{},"name":"Identifiers for Intel Xeon Scalable Processors (First and Second Generation) for Microsoft Windows","per_device_install_time_seconds":3600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0","10.0","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U45","U38","U38","03020101","U40","U41","U32","H08","H08","I41","02020001","U33","03020102","I43","I42","U37","U39","U40","U36","U34","U30","U34","U31","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-qlgc-fastlinq-8.74.0.1-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"1","version":"8.74.0.1-1"},{"name":"kmod-qlgc-fastlinq-8.74.0.1-1.rhel9u3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"1","version":"8.74.0.1-1"}],"installation_dependency":{},"name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U30","O43","U40","U56","U50","U61","U60","A43","A47","02020001","U33","03020102","U37","U39","U36","U34","U30","A48","U34","U47","U47","U47","03020101","A40","A46","U46","U31","U46","U48","U26","U39","U31"]},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053637.exe","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"1","version":"0.2.3.0"}],"installation_dependency":{},"name":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0","10.0","10.0.20317"]}],"supported_platforms":true,"supported_products":["U30","U45","U34","U37","U38","U38","I41","U33","I43","I42","H08","U39","U40","U39","U41","U34","U32","H08","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060552.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82a707e7"],"type_of_change":"0","version":"1.1.0.0"}],"installation_dependency":{},"name":"NVMe Drive Eject NMI Fix for Intel Xeon Processor Scalable Family for Microsoft Windows 64-bit","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-2020159000ea"],"supported_operating_systems":[{"os":"Windows","version":["10.0","10.0","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U30","U45","U34","U37","U38","U38","I41","U33","I43","I42","U39","U40","U41","U31","U32","U36","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052927.exe","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWBHR Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57424852"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"},{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055338.zip","target_guids":["4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP055338","version":"HPG3.5-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-304757434642","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3234-304757434555"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053392.zip","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP053392","version":"HPG1.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-3047574b4752"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058357.zip","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP058357","version":"HPD3.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.10 (02/22/2024)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.10 (02/22/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U34_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.0","6.5","6.7","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U34","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"libbnxt_re-228.0.133.0-rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"1","version":"228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 2.","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"PICGen10-1.1.4-1.fwpkg","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"1","version":"1.1.4"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]}]}]},"name":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.0","6.5","6.7","7.0"]}],"supported_platforms":true,"supported_products":["A41","U44","U43","A43","A42","A42","A43","U41","U32","A42","U46","U50","U50","U61","U34","A43","U33","U36","U60","U30","U34","U56","A40","U46","U39","U46","U31","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059873.exe","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A47"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059326.zip","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP059326","version":"HPD7.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EH0600JDYTN Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3048-3630-304a4459544e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u30-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen10 (U30) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U30"]},{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM4 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_UBM4_1.24_F.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901504000000","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_UBM4_1.24_F.fwpkg","target_guids":["9675b54e-1c96-44c3-a7a1-901504000000"],"type_of_change":"1","version":"1.24"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4650","description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4650","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 servers usage","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","8.0","15.0","10.0.20317","8.0","9.0","10.0.14393.17599","7.0","12.0"]}],"supported_platforms":false,"supported_products":["A42","A43","A43","A55","U46","A55","A56","A56","U58","U58","U54","U46","U54","U59","A42","U63","I45","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-ec908c3650-HPG9-3.1.x86_64.rpm","target_guids":["002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG9"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MM2000GEFRA Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-324d-3030-304745465241"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWVBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57564252","Version":"HPK2"},{"DeviceName":"VO001920KWVBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564254","Version":"HPK2"},{"DeviceName":"VO003840KWVBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564255","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059332.zip","target_guids":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3130-3932-304b57564254","562340a5-304f-3330-3834-304b57564255"],"type_of_change":"1","version":"HPK2","vib_list":[{"name":"CP059332","version":"HPK2.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi  - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3130-3932-304b57564254","562340a5-304f-3330-3834-304b57564255"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.3006"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-mellanox-ethernet-only-1.0.20-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.20"}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox Ethernet only adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"supported_operating_systems":[{"os":"Linux","version":["6.0","11.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U38","U38","A43","A42","A42","A43","U40","U39","U41","U32","A42","U25","U50","U19","U22","U50","U61","A43","A47","P89","P89","U37","U36","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U39"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-mellanox-eth-only-mft-1.0.6-3.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.6"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"supported_operating_systems":[{"os":"Linux","version":["6.0","7.0","8.0","11.0","12.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["U38","U38","A43","A42","A42","A43","U40","U32","A42","U50","U50","U61","A43","A47","U37","A48","U47","U47","U47","U47","U56","A46","U46","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-68b12e54d2-HPG6-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWCBC and MB002000GWCBD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-qlgc-qla2xxx-10.02.11.00_k1-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.11.00-k1"}],"installation_dependency":{},"name":"Red Hat Enterprise Linux 9 update 2 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD8"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD8"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD8"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD8"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055387.zip","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP055387","version":"HPD8.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058391.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"type_of_change":"1","version":"1.13.242.0"}],"installation_dependency":{},"name":"Intel icea Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","A56","U65","H10","H08","U58","A55","A42","U50","U58","H08","U54","U61","U57","U63","A43","02020001","03020102","U54","U60","A43","03030201","U59","U47","U47","03020101","A56","A46","H10","U46","H10","U46","H09","U62","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400KYDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IASHPK4.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304b59444b56","Version":"HPK4"},{"DeviceName":"EO000800KYDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IASHPK4.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304b59444c41","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-6758a46eb7-HPK4-2.1.x86_64.rpm","target_guids":["452340a5-304f-3030-3430-304b59444b56","452340a5-304f-3030-3830-304b59444c41"],"type_of_change":"1","version":"HPK4"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - EO000400KYDKV and EO000800KYDLA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304f-3030-3830-304b59444c41","452340a5-304f-3030-3430-304b59444b56"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059323.zip","target_guids":["4d2340a5-304b-3030-3430-304b5744554b","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3130-3932-304b57445548"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP059323","version":"HPK4.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi  - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3030-3430-304b5744554b","4d2340a5-304b-3030-3830-304b5744554c","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3438-304b57445545","562340a5-304b-3030-3936-304b57445546","562340a5-304b-3130-3932-304b57445548"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055346.zip","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP055346","version":"HPG3.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3730-3638-30475753584e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"228.1.111000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"228.1.111000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"228.1.111000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"228.1.111000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"228.1.111000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059026.exe","target_guids":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"type_of_change":"1","version":"5.4.0.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]}]}]},"name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","03030201","02020001","A40","03020102","03020101"]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp059602.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059603.exe","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":true,"supported_products":["U61","FTP"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055150.exe","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304757444645"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR216i-p_Gen10P_52.26.3-5379_A.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.26.3-5379"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_MR216i-p_Gen10P_52.26.3-5379_A.fwpkg","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032b"],"type_of_change":"1","version":"52.26.3-5379"}],"installation_dependency":{},"name":"Firmware Package - HPE MR216i-p Gen10 Plus Tri Mode Controller ","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e21590032b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","10.0.14393.17599","8.0","15.0","12.0","10.0.20317","7.0","9.0","8.0"]}],"supported_platforms":false,"supported_products":["U46","A43","A43","A42","A42","U46","U46","U61","U60"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U37_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.0","6.5","6.7","7.0"]}],"supported_platforms":false,"supported_products":["U37"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053400.zip","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP053400","version":"HPG3.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304757444645"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-ixgbevf-4.18.7-1.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"1","version":"4.18.7-1"},{"name":"kmod-hp-ixgbevf-4.18.7-1.rhel9u0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"1","version":"4.18.7-1"},{"name":"kmod-hp-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"1","version":"4.18.7-1"}],"installation_dependency":{},"name":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400KYDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IASHPK4.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304b59444b56","Version":"HPK4"},{"DeviceName":"EO000800KYDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IASHPK4.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304b59444c41","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059259.exe","target_guids":["452340a5-304f-3030-3430-304b59444b56","452340a5-304f-3030-3830-304b59444c41"],"type_of_change":"1","version":"HPK4"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - EO000400KYDKV and EO000800KYDLA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304f-3030-3830-304b59444c41","452340a5-304f-3030-3430-304b59444b56"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058432.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"type_of_change":"1","version":"1010.84.0.1012"}],"installation_dependency":{},"name":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for  Windows Server 2016, Windows Server 2019 and Windows Server 2022","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":["A41","U65","U65","U38","U38","A43","U62","A42","A42","A43","U54","A56","U40","U41","U32","A42","U58","A55","O43","U50","I44","U58","U54","U61","U60","U63","A43","A47","U54","U33","I43","I42","U37","U40","U36","I45","U34","U30","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U31","U46","U48","U63","U58","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-ice-1.12.6-1.rhel8u6.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.12.6-1"},{"name":"kmod-ice-1.12.6-1.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.12.6-1"},{"name":"kmod-ice-1.12.6-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.12.6-1"}],"installation_dependency":{},"name":"Intel ice Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U40","U41","U32","A42","H08","U58","A55","O43","H10","U56","U50","U58","H08","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U54","U46","U46","H09","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052926.exe","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWFVB Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57465642"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp057642.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.002"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057643.exe","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"0","version":"04.01.05.002"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"0.1.4.0","description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0","10.0","10.0.20317"]}],"supported_platforms":true,"supported_products":["U30","U45","U34","U37","U38","U38","I41","H08","U33","I43","I42","U39","U40","U39","U41","U31","U32","H08","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055179.exe","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v3.00 (01/26/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"A43_3.00_01_26_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":false,"supported_products":["A43","A43","A43"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-elx-lpfc-14.2.589.21-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"14.2.589.21"}],"installation_dependency":{},"name":"Red Hat Enterprise Linux 8 Update 8 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"libbnxt_re-228.0.133.0-rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"1","version":"228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 1.","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"mft-4.26.1-3.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"0","version":"4.26.1-3"},{"name":"kernel-mft-mlnx-kmp-default-4.26.1_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"0","version":"4.26.1-3"}],"installation_dependency":{},"name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP4 (AMD64/EM64T)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U43","U38","U38","A43","A42","A42","A43","U45","U40","U39","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","U37","U36","U34","U30","A48","U34","03030201","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v3.00 (01/26/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-a43-3.00_2024_01_26-2.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A43","A43","A43"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-82894b9e0a-HPG1-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWRTC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304757525443"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055303.zip","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP055303","version":"HPD2.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a574b4755"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8fafc9efb2-HPD8-1.1.x86_64.rpm","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.2006"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.3006"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.3006"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.13-3.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"type_of_change":"1","version":"1.0.13"}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1013159000ef","a6b1a447-382a-5a4f-15b3-101715900257","a6b1a447-382a-5a4f-15b3-101715900255"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A43","A42","A42","A43","U32","A42","U27","U50","U19","U50","U61","A43","A47","02020001","03020101","03020102","P89","P89","U37","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055190.exe","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-334f-3230-304a4646434c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059710.exe","target_guids":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"storcli-007.2613.0000.0000-1.noarch.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"type_of_change":"0","version":"007.2613.0000.0000"}],"installation_dependency":{},"name":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10 and Gen11 Controllers)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":true,"supported_products":["A43","A42","A42","A43","U54","U65","U32","A42","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059037.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"type_of_change":"1","version":"221.0.5.0"}],"installation_dependency":{},"name":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U44","U43","U38","U38","03020101","U40","U41","U32","O43","U36","02020001","U33","03020102","U37","U39","U40","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055268.zip","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP055268","version":"HPD6.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JEHMD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3830-304a45484d44"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD8"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD8"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD8"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD8"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055388.exe","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-iegen10-0.2.3.0-4.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"1","version":"0.2.3.0"}],"installation_dependency":{},"name":"Online ROM Flash for Linux - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U30","U45","U34","U38","U38","I41","U39","U33","I43","I42","H08","U37","U40","U39","U41","U31","U32","H08","U31","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058378.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecee44d472"],"type_of_change":"1","version":"4.1.251.0"}],"installation_dependency":{},"name":"HPE Intel ixs Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_Cooper_SCOOPRHPESD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3030-3936-30525852514b","Version":"HPD3"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_Cooper_SCOOPRHPESD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3130-3932-305258525248","Version":"HPD3"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_Cooper_SCOOPRHPESD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3330-3834-30525852524b","Version":"HPD3"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_Cooper_SCOOPRHPESD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3030-3936-30525852514c","Version":"HPD3"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_Cooper_SCOOPRHPESD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3130-3932-30525852524c","Version":"HPD3"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_Cooper_SCOOPRHPESD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3330-3834-30525852524e","Version":"HPD3"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_Cooper_SCOOPRHPESD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3730-3638-305259455744","Version":"HPD3"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Seagate_Cooper_SCOOPRHPESD3.fwpkg","target_guids":["4d2340a5-304f-3030-3936-30525852514b","4d2340a5-304f-3130-3932-305258525248","4d2340a5-304f-3330-3834-30525852524b","562340a5-304f-3030-3936-30525852514c","562340a5-304f-3130-3932-30525852524c","562340a5-304f-3330-3834-30525852524e","562340a5-304f-3730-3638-305259455744"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3030-3936-30525852514b","4d2340a5-304f-3130-3932-305258525248","4d2340a5-304f-3330-3834-30525852524b","562340a5-304f-3030-3936-30525852514c","562340a5-304f-3130-3932-30525852524c","562340a5-304f-3330-3834-30525852524e","562340a5-304f-3730-3638-305259455744"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.17600.18999","10.0.14393.17599","8.0","7.0","15.0","12.0","7.0","9.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDA"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDA"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDA"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDA"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b1c9eaf74c-HPDA-3.1.x86_64.rpm","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"type_of_change":"1","version":"HPDA"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD8"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD8"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD8"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD8"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-bdfb8e99d9-HPD8-2.1.x86_64.rpm","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058996.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"qfle3i","version":"2.1.14.0-1OEM.700.1.0.15843807"},{"name":"qcnic","version":"2.0.66.0-1OEM.700.1.0.15843807"},{"name":"qfle3f","version":"2.1.33.0-1OEM.700.1.0.15843807"},{"name":"qfle3","version":"1.4.46.0-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","U40","U41","U32","U30","O43","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"qlgc-fastlinq-kmp-default-8.74.0.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"1","version":"8.74.0.1-1"},{"name":"qlgc-fastlinq-kmp-default-8.74.0.1_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"1","version":"8.74.0.1-1"}],"installation_dependency":{},"name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U30","O43","U40","U56","U50","U61","U60","A43","A47","02020001","U33","03020102","U37","U39","U36","U34","U30","A48","U34","U47","U47","U47","03020101","A40","A46","U46","U31","U46","U48","U26","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055984.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"type_of_change":"1","version":"2.1.246.0"}],"installation_dependency":{},"name":"HPE Intel vxs Driver for Windows Server 2022","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1565159000d1","a6b1a447-382a-5a4f-8086-1565159000d2"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","A40","U33","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-iegen10plus-1.0.0.22-4.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000303"],"type_of_change":"1","version":"1.0.0.22"}],"installation_dependency":{},"name":"Online ROM Flash for Linux - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U47","U47","U56","H10","U50","U46","H10","U46","I44","H10"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8f9bf23306-HPG1-7.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b","562340a5-304b-3130-3932-30475841574e"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"23.10-1.1.9.1"},{"name":"mlnx-ofa_kernel-kmp-default-23.10_k5.14.21_150400.22-OFED.23.10.1.1.9.1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"23.10-1.1.9.1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"name":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ConnectX-4, ConnectX-5 and ConnectX-6 Driver for SUSE LINUX Enterprise Server 15 SP4 (AMD64/EM64T)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U65","U43","U38","U38","A43","U65","A42","A42","A43","U45","A56","U40","U39","U41","U32","A42","U58","U25","A55","U21","U50","U56","U50","U54","U61","U58","U63","U59","A43","A47","02020001","U54","P89","P89","U37","U36","U34","U30","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U46","U54","U46","U46","A55","U62","U63","U58","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059321.zip","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP059321","version":"HPD8.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWTFD and MB012000JWTFC  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058414.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"type_of_change":"1","version":"1.14.201.0"}],"installation_dependency":{},"name":"Intel iavf Driver for Windows Server 2019","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-157180860001"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A42","A55","U56","U54","A56","U65","H10","H08","A55","A42","H08","U54","U61","U58","U63","02020001","03020102","U54","U60","03030201","U59","U65","03020101","A56","U58","H10","H10","H09","U62","U63","U58"]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp059616.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-microserverv2gen10plus_me-06.00.03.604-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U64","FTP"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052803.exe","target_guids":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG2"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG2"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG2"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG2"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-4fbb6d96e5-HPG2-1.1.x86_64.rpm","target_guids":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"type_of_change":"1","version":"HPG2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.28.41"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059044.exe","target_guids":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"type_of_change":"1","version":"5.4.0.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.42 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NX1 1Gb Driver is required and should be already active"}]}]}]},"name":"Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U46","A42","A42","U65","U43","A43","U46","A42","A42","U56","U54","U65","A42","U58","U47","U46","A55","U50","H10","U50","U54","U61","U58","U63","U59","A43","A43","U54","U62","U60","U65","U47","U47","U47","A43","A56","A56","A46","H10","A55","U46","H10","U46","U48","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053430.zip","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP053430","version":"HPG3.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3330-3834-304757535346","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3030-3438-304757535343"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055305.zip","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP055305","version":"HPD2.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a574b474e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053453.zip","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP053453","version":"HPG1.2-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB,MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b","562340a5-304b-3130-3932-30475841574e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u37-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["12.0","11.0","7.0","6.0","15.0","8.0"]}],"supported_platforms":false,"supported_products":["U37"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059291.exe","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055194.exe","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SPSGen10_04.01.05.002.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.002"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"SPSGen10_04.01.05.002.fwpkg","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"0","version":"04.01.05.002"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0","8.0"]}],"supported_platforms":true,"supported_products":["U30","U45","U34","U37","U38","U38","I41","H08","U33","I43","I42","U39","U40","U39","U41","U31","U32","H08","U31","U34"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR416i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.26.3.5379"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP060238.zip","target_guids":["a6b1a447-382a-5a4f-1000-10e215900293"],"type_of_change":"2","version":"52.26.3.5379","vib_list":[{"name":"CP060238","version":"52.26.3.5379.20-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Controller Firmware Flash for ESXi7.0 and 8.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900293"],"supported_operating_systems":[{"os":"VMware","version":["8.0","7.0"]}],"supported_platforms":false,"supported_products":["U30","A43","A43","A42","A42","U46","SPP","U46","U61","U32","U60"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U61_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059520.exe","target_guids":["00000000-0000-0000-0000-00000000023c"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U61","FTP"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-f3faa195ff-HPD7-11.1.x86_64.rpm","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"1","version":"HPD7"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EH0600JDYTN Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3048-3630-304a4459544e"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-017797f12e-HPD4-2.1.x86_64.rpm","target_guids":["4d2340a5-3042-3431-3030-304a58554343"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JXUCC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a58554343"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06154-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.40.1000"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06250-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.40.1000"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06251-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.40.1000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.12-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.12"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","03020102","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWVBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57564252","Version":"HPK2"},{"DeviceName":"VO001920KWVBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564254","Version":"HPK2"},{"DeviceName":"VO003840KWVBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564255","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-a9843986b0-HPK2-3.1.x86_64.rpm","target_guids":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3130-3932-304b57564254","562340a5-304f-3330-3834-304b57564255"],"type_of_change":"1","version":"HPK2"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3330-3834-304b57564255","562340a5-304f-3130-3932-304b57564254"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7dd508ef"],"type_of_change":"0","version":"1.0.0.0-4"}],"installation_dependency":{},"name":"HPE Emulex Smart SAN Enablement Kit for Linux","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055180.exe","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK003840GWSXL  Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-30475753584c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG4"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG4"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG4"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055425.zip","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP055425","version":"HPG4.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3130-3630-3050584d544e","Version":"HPD2"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3330-3230-3050584d5456","Version":"HPD2"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3630-3430-3050584d5541","Version":"HPD2"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3130-3932-3050584d544c","Version":"HPD2"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3330-3834-3050584d5452","Version":"HPD2"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3730-3638-3050584d5454","Version":"HPD2"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3531-3336-3050584d5455","Version":"HPD2"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Kioxia_PM7_KAPM7ALSHPD2.fwpkg","target_guids":["4d2340a5-304f-3130-3630-3050584d544e","4d2340a5-304f-3330-3230-3050584d5456","4d2340a5-304f-3630-3430-3050584d5541","562340a5-304f-3130-3932-3050584d544c","562340a5-304f-3330-3834-3050584d5452","562340a5-304f-3730-3638-3050584d5454","562340a5-304f-3531-3336-3050584d5455"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3336-3050584d5455","562340a5-304f-3730-3638-3050584d5454","562340a5-304f-3330-3834-3050584d5452","562340a5-304f-3130-3932-3050584d544c","4d2340a5-304f-3630-3430-3050584d5541","4d2340a5-304f-3330-3230-3050584d5456","4d2340a5-304f-3130-3630-3050584d544e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v3.00 (01/26/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059510.exe","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A42","A42","A42"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-4c048aaeb0-HPD8-7.1.x86_64.rpm","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VO007680JWCNK and VO015300JWCNL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3330-304a57434e4c","562340a5-304f-3730-3638-304a57434e4b"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059949.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0130"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD2"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD2"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD2"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059084.zip","target_guids":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP059084","version":"HPD2.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-d1cf327bc4-HPG3-6.1.x86_64.rpm","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK003840GWSXL Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-30475753584c"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u45-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U45"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPK2"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPK2"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059314.zip","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPK2","vib_list":[{"name":"CP059314","version":"HPK2.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi  - MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3054-3630-3430-304b57484145","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3130-3630-304b57484143"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b04257b77b-HPDA-3.1.x86_64.rpm","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPDA"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - MM1000JEFRB and MM2000JEFRC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-92d876cfea-4ICRHPK3-8.1.x86_64.rpm","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"1","version":"4ICRHPK3"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","12.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059306.exe","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM6 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_UBM6_1.04_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901506000000","Version":"1.04"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_UBM6_1.04_A.fwpkg","target_guids":["9675b54e-1c96-44c3-a7a1-901506000000"],"type_of_change":"1","version":"1.04"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4650","description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4650","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Firmware Package - UBM6 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 servers usage","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","8.0","15.0","10.0.20317","8.0","9.0","10.0.14393.17599","7.0","12.0"]}],"supported_platforms":false,"supported_products":["U30","A42","A43","A42","U32","U46","A55","A43","U46","A55","A56","A56","U54","U46","U54","U59","U54","U63","U63","I45","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-035a863453-HPK5-5.1.x86_64.rpm","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"1","version":"HPK5"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"},{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055412.zip","target_guids":["452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3330-304a57534a50"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP055412","version":"HPD5.6-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-3ab4c70e64-HPG4-14.1.x86_64.rpm","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055189.exe","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-5600-314f-3932-304a46444756","002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-334f-3834-304a46444841"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055310.zip","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP055310","version":"HPG4.5-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD8"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-c7df7ceedb-HPD8-3.1.x86_64.rpm","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3630-304a57485048","452340a5-3048-3030-3930-304a5748504b"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-d550523365-HPD3-2.1.x86_64.rpm","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE 100Gb 1-Port OP101 QSFP28 x16 OPA Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.12.0.0.0.rom","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0159000E8","Version":"1.12.000"},{"DeviceName":"HPE 100Gb 1p OPA 860z FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.12.0.0.0.rom","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F01590021C","Version":"1.12.000"},{"DeviceName":"HPE 100Gb 1-Port OP101 QSFP28 x8 OPA Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.12.0.0.0.rom","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0159000E7","Version":"1.12.000"},{"DeviceName":"Intel Corporation Omni-Path HFI Silicon 100 Series [discrete]","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.12.0.0.0.rom","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0808624F0","Version":"1.12.000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-cornelis-opa-hfi-1.12.0-3.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-8086-24F0159000E8","a6b1a447-382a-5a4f-8086-24F01590021C","a6b1a447-382a-5a4f-8086-24F0159000E7","a6b1a447-382a-5a4f-8086-24F0808624F0"],"type_of_change":"1","version":"1.12.0"}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE OPA adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-24f0159000e8","a6b1a447-382a-5a4f-8086-24f01590021c","a6b1a447-382a-5a4f-8086-24f0159000e7","a6b1a447-382a-5a4f-8086-24f0808624f0"],"supported_operating_systems":[{"os":"Linux","version":["6.0","11.0","7.0","12.0","15.0","8.0"]}],"supported_platforms":false,"supported_products":["A41","U17","P86","U38","U38","U34","A42","A43","U50","U40","U41","U12","U13","U32","A42","U14","U13","U25","P85","U21","U24","U19","U22","P89","U50","U58","P99","U63","A43","A47","U54","U14","P89","P89","U37","U15","U15","U36","U34","U30","A48","P92","U20","U20","U47","U47","U47","U47","A55","A40","A46","U46","U46","U46","U59","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055411.zip","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP055411","version":"HPD5.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD2"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD2"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD2"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8f501d6cf1-HPD2-6.1.x86_64.rpm","target_guids":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK5"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK5"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK5"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK5"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK5"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK5"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059787.zip","target_guids":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"type_of_change":"1","version":"HPK5","vib_list":[{"name":"CP059787","version":"HPK5.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi  -  VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"DL20ML30Gen10SPS_05.01.04.913.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.913"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"DL20ML30Gen10SPS_05.01.04.913.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.913"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":true,"supported_products":["U44","U43"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp060113.exe","target_guids":["00000000-0000-0000-0000-00000000022f"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A48"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020907.bin","InstallDurationSec":380,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.09.07"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020907.bin","InstallDurationSec":380,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.09.07"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020205.bin","InstallDurationSec":380,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.02.05"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020205.bin","InstallDurationSec":380,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.02.05"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020205.bin","InstallDurationSec":380,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.02.05"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020205.bin","InstallDurationSec":380,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.02.05"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020907.bin","InstallDurationSec":380,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.09.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020907.bin","InstallDurationSec":380,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.09.07"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058495.zip","target_guids":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2023.10.01","vib_list":[{"name":"CP058495","version":"2023.10.01.4-7.0.0.15843807"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.0.1-3","description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active"}]}]}]},"name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 7.0","per_device_install_time_seconds":380,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-igb-5.14.16-1.rhel9u0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"5.14.16-1"},{"name":"kmod-hp-igb-5.14.16-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"5.14.16-1"},{"name":"kmod-hp-igb-5.14.16-1.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"5.14.16-1"}],"installation_dependency":{},"name":"HPE Intel igb Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U54","U40","U41","U32","A42","U58","A55","O43","U56","U50","U58","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","03020101","A40","A56","A46","U58","U46","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-95af9a555e-HPG6-3.1.x86_64.rpm","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-3047464a5445"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.5"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.5"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058405.zip","target_guids":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8"],"type_of_change":"1","version":"3.22.0","vib_list":[{"name":"CP058405","version":"3.22.0.10-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE Intel Online Firmware Upgrade Utility VMware for HPE ProLiant Gen9 and Gen10 server series Only.","per_device_install_time_seconds":1800,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1581159000f8"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900382","Version":"6.52"},{"DeviceName":"HPE_SR_Gen10_6.52","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR_Gen10_6.52_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900383","Version":"6.52"}]},"MinimumActiveVersion":"5.61","Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_SR_Gen10_6.52_A.fwpkg","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f15900383"],"type_of_change":"1","version":"6.52"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"name":"Firmware Package  - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers","per_device_install_time_seconds":400,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","8.0","15.0","10.0.20317","9.0","8.0","10.0.14393.17599","7.0","12.0"]}],"supported_platforms":true,"supported_products":["U45","U65","U38","U38","A43","U65","U62","A42","A42","A43","U54","U40","U39","U41","U32","A42","A46","U46","A55","O43","U50","I44","U54","U61","U58","U63","A43","U37","A47","U33","I43","I42","U54","U60","U40","U36","U34","U30","U64","A48","U57","U34","U59","U47","U47","A55","A56","A56","U58","U46","U39","U46","U48","U63","U58","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPNSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD2"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPNSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-d4be2aecbb-HPD2-4.1.x86_64.rpm","target_guids":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.3006"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057779.zip","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP057779","version":"1.0.0-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (ESXi 8.0) for Mellanox Open Ethernet cards","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U32","A42","U50","U50","U61","A43","A47","U30","A48","U47","U47","U47","U47","U56","A46","U46","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-252770cdda-HPD7-11.1.x86_64.rpm","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB8000JFECQ Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3842-3030-304a46454351"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image.","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"IEGen10_0.2.3.0.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"IEGen10_0.2.3.0.fwpkg","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"1","version":"0.2.3.0"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0"]}],"supported_platforms":true,"supported_products":["U30","U45","U34","U37","U38","U38","I41","H08","U33","I43","I42","U39","U40","U39","U41","U34","U32","H08","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD3"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD3"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD3"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD3"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD3"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD3"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD3"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD3"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD3"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD3"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD3"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053487.zip","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP053487","version":"HPD3.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","562340a5-304f-3531-3330-305058444256","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin","InstallDurationSec":800,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin","InstallDurationSec":800,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP052254.zip","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"1","version":"1.00","vib_list":[{"name":"CP052254","version":"1.00.5-7.0.0.15843807"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Backplane Expander Firmware","per_device_install_time_seconds":800,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":true,"supported_products":["U38","U38","U38"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"6.52"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"6.52"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"6.52"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"6.52"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"6.52"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"6.52"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"6.52"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058431.zip","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"type_of_change":"1","version":"6.52","vib_list":[{"name":"CP058431","version":"6.52.6-8.0.0.20143090"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["A41","A40"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U60_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U60_2.00_02_01_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000023e"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE Proliant DL20 Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":false,"supported_products":["FTP","U60"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"hponcfg-6.0.0-0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8"],"type_of_change":"0","version":"6.0.0-0"}],"installation_dependency":{},"name":"HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3306103c3381","a6b1a447-382a-5a4f-103c-3307103c3381","a6b1a447-382a-5a4f-103c-3308103c3381","a6b1a447-382a-5a4f-103c-3300103c3381","a6b1a447-382a-5a4f-103c-3301103c3381","a6b1a447-382a-5a4f-103c-3302103c3381","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"supported_operating_systems":[{"os":"Linux","version":["10.0","11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["P95","I30","I31","A43","U40","I38","U41","Carbondale14","U13","U32","Carbondale14","U14","U14","U25","I36","U19","P78","U34","A47","U33","U24","A48","U64","O42","U39","U38","U38","J10","A42","P85","J03","Carbondale14","P75","U23","U21","P89","A45","I44","I40","I32","P83","P77","I37","P89","P89","U15","U15","P99","U30","P73","A26","P88","A55","I39","A55","A56","A56","U48","U26","U31","U31","A41","U45","P94","U13","P70","P71","J02","A28","P72","P75","U24","U51","P73","I41","U18","U18","I43","I42","U37","I31","U18","U20","U20","I36","A40","U17","P86","U44","U43","J06","A48","A42","I40","P75","U50","U22","U50","U61","J05","J04","A43","P80","P74","U36","U60","P92","U34","P75","U47","U47","U47","U47","A46","U46","U46","P79","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055173.exe","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43","4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"elx-lpfc-kmp-default-14.2.589.21_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"14.2.589.21"}],"installation_dependency":{},"name":"SuSE Linux Enterprise Server 15 Service Pack 5 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052315.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59"],"type_of_change":"2","version":"106.12.6.0"}],"installation_dependency":{},"name":"HPE Smart Array S100i SR Gen10 SW RAID Driver for Windows Server 2016 and Windows Server 2019","per_device_install_time_seconds":400,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a256159000e6"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U38","U38","U40","U39","U41","U32","U33","I43","I42","U37","U40","U36","U34","U30","U34","A40","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058500.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.9.21"}],"installation_dependency":{},"name":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK76H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK76H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK76H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059335.zip","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"1","version":"EPK76H3Q","vib_list":[{"name":"CP059335","version":"EPK76H3Q.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3654-3448bda98199","4d2340a5-505a-4a4c-3354-3248fdc50136"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059325.zip","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP059325","version":"HPK3.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD2"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059287.exe","target_guids":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF and MB008000JYDPC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053890.zip","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP053890","version":"HPD8.1-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hca-mellanox-vpi-eth-ib-1.0.12-3.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.12"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on Linux x86_64 platform","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1"],"supported_operating_systems":[{"os":"Linux","version":["6.0","11.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","A40","U19","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058360.exe","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWWQU and MB006000GWWQT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055164.exe","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYZD and MB4000JVYZC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304a56595a43","002340a5-4d00-3642-3030-304a56595a44"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-qlgc-fastlinq-8.74.0.1-1.rhel8u9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"1","version":"8.74.0.1-1"},{"name":"kmod-qlgc-fastlinq-8.74.0.1-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"1","version":"8.74.0.1-1"}],"installation_dependency":{},"name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U30","O43","U40","U56","U50","U61","U60","A43","A47","02020001","U33","03020102","U37","U39","U36","U34","U30","A48","U34","U47","U47","U47","03020101","A40","A46","U46","U31","U46","U48","U26","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059090.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"23.10.26252.0"}],"installation_dependency":{},"name":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101815b30117","a6b1a447-382a-5a4f-15b3-101e15b30040","a6b1a447-382a-5a4f-15b3-101e15b30042","a6b1a447-382a-5a4f-15b3-101615b30102","a6b1a447-382a-5a4f-15b3-101615b30047","a6b1a447-382a-5a4f-15b3-101815b30116","a6b1a447-382a-5a4f-15b3-101815b30052","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101e15b30007","a6b1a447-382a-5a4f-15b3-101e15b30012"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U65","A43","A42","A42","U56","U54","A56","U65","A42","A46","A55","H10","U50","U54","U61","U58","U63","A43","A47","U54","U62","U60","U57","U63","03030201","U47","U47","U47","A43","A56","U58","H10","A55","U46","H10","U46","U48","U59","U58"]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_CimarronBP_SCIMARBPNTG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-3042-3230-3030-304759444e4b","Version":"HPG1"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_CimarronBP_SCIMARBPNTG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-3042-3430-3030-304759445044","Version":"HPG1"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Seagate_CimarronBP_SCIMARBPNTG1.fwpkg","target_guids":["4d2340a5-3042-3230-3030-304759444e4b","4d2340a5-3042-3430-3030-304759445044"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - MB002000GYDNK and MB004000GYDPD","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3230-3030-304759444e4b","4d2340a5-3042-3430-3030-304759445044"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-ca21e169e2-HPG1-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWKGV Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-3047574b4756"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059276.exe","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"1","version":"HPD7"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EH0600JDYTN Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3048-3630-304a4459544e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055347.zip","target_guids":["562340a5-304b-3030-3234-304757434644","562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP055347","version":"HPG3.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK   Drives.","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-30475743464b","562340a5-304b-3130-3932-304757434648","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3234-304757434644"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059283.exe","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-5600-314f-3630-304a45414246","002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp059616.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059618.exe","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U64","FTP"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058992.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"type_of_change":"1","version":"8.72.11.0"}],"installation_dependency":{},"name":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U38","A43","A42","A42","U56","H10","A42","U50","U61","A43","A47","U39","U60","A48","U47","U47","U47","A43","A46","H10","U46","H10","U46","U48"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"ssaducli-6.30-8.0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"type_of_change":"1","version":"6.30.8.0"}],"installation_dependency":{},"name":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","8.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["U27","P95","A43","A43","U54","U40","U41","U12","U13","U32","Carbondale14","U14","U14","U25","Carbondale14","U19","U34","A47","U33","U54","U40","I45","A48","O42","U58","U39","U38","U38","U38","U38","U38","U65","A42","P85","A55","U23","U21","P89","I44","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U31","U31","A42","U13","U24","U14","U18","U18","I43","I42","U37","U18","U57","U20","U20","A40","U62","U63","U17","P86","A42","I40","U65","A46","U22","U50","U54","U63","A43","U39","U40","U36","U58","P92","U34","U47","U47","U58","Carbondale14","U46","U46"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.09"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.09"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.09"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058191.zip","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"1","version":"4.18.50","vib_list":[{"name":"CP058191","version":"4.18.50.2-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["A41","03020101","02020001","A40","03020102"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U43_3.00_02_01_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.5","6.7","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U43"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXV4_OCP_4p30_NCSIwPLDMoMCTP_8001AF22.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"4.30"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_E810_XXV4_OCP_4p30_NCSIwPLDMoMCTP_8001AF22.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-15938086000c"],"type_of_change":"1","version":"4.30"}],"installation_dependency":{},"name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","U65","H10","H08","A55","A42","U50","H08","U54","U61","U58","U63","A43","A47","U54","U60","A48","U57","U59","U47","U47","A43","A56","A56","U58","H10","U46","H10","U46","H09","U62","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-24384980ec-HPD1-6.1.x86_64.rpm","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06154-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.40.1000"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06250-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.40.1000"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_40_1000-P06251-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.40.1000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP060192.zip","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.7","vib_list":[{"name":"CP060192","version":"1.0.0-7.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","03020102","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058494.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"type_of_change":"1","version":"2023.10.01","vib_list":[{"name":"qlnativefc","version":"5.4.82.0-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0","per_device_install_time_seconds":380,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U46","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058395.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"type_of_change":"1","version":"4.1.251.0"}],"installation_dependency":{},"name":"HPE Intel ixn Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055593.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"14.2.537.0"}],"installation_dependency":{},"name":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-smartarray-7b5e8400dd-1.27-3.1.x86_64.rpm","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["A46","U47","U47"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053025.exe","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWAYN and MB008000GWAYL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-cfd7436fcc-HPD3-7.1.x86_64.rpm","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57554442"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-elx-lpfc-14.2.589.21-1.rhel8u9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"14.2.589.21"}],"installation_dependency":{},"name":"Red Hat Enterprise Linux 8 Update 9 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U60_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059515.exe","target_guids":["00000000-0000-0000-0000-00000000023e"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["FTP","U60"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055205.exe","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWEBH and EG000300JWEBF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57454246","452340a5-3047-3030-3630-304a57454248"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp057556.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.913"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057557.exe","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.913"}],"installation_dependency":{},"name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U44","U43"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWVBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57564252","Version":"HPK2"},{"DeviceName":"VO001920KWVBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564254","Version":"HPK2"},{"DeviceName":"VO003840KWVBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564255","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059289.exe","target_guids":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3130-3932-304b57564254","562340a5-304f-3330-3834-304b57564255"],"type_of_change":"1","version":"HPK2"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3130-3932-304b57564254","562340a5-304f-3330-3834-304b57564255"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-2e4c61fc63-HPD5-6.1.x86_64.rpm","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - EG000300JWBHR Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57424852"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U30_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U30"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059535.exe","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U40","U40"]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp057560.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.913"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057561.exe","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.913"}],"installation_dependency":{},"name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":true,"supported_products":["U48","FTP"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u43-3.00_2024_02_01-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","15.0","12.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U43"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-ixgbevf-4.18.7-1.rhel8u6.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"1","version":"4.18.7-1"},{"name":"kmod-hp-ixgbevf-4.18.7-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"1","version":"4.18.7-1"},{"name":"kmod-hp-ixgbevf-4.18.7-1.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"1","version":"4.18.7-1"}],"installation_dependency":{},"name":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"lsi-megaraid_sas-kmp-default-07.726.03.00_sles15sp4-1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.726.03.00"},{"name":"lsi-megaraid_sas-kmp-default-07.726.03.00_sles15sp5-1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.726.03.00"}],"installation_dependency":{},"name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p Gen11 controller  Driver 64-bit SUSE LINUX Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","U54","U65","U32","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U58","U46","U46","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-693b9a2853-HPD4-6.1.x86_64.rpm","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWFVC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3830-304a57465643"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053386.zip","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP053386","version":"HPG1.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-3047574b4756"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053315.zip","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP053315","version":"1.0.5-7.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","A40","U19","U41","U31","U32","U31","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058415.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"type_of_change":"1","version":"1.14.201.0"}],"installation_dependency":{},"name":"HPE Intel iavf Driver for Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37cd80860001","a6b1a447-382a-5a4f-8086-157180860001"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3429.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3429.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3429.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3429.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3429.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3429.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058409.exe","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"1","version":"5.3.6.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.16.202.0","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.16.202.0","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"Intel Online Firmware Upgrade Utility for Windows Server x64 Editions","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U65","A42","A55","03020101","U54","U65","A42","U58","A55","U50","U58","U54","U61","U57","U63","U59","A43","A47","02020001","03020102","U54","U64","A42","U62","U60","A48","03030201","U47","U47","U56","A56","A56","A46","U46","U46","U46","U48","U63","U58"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.00 (02/01/2024)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.00 (02/01/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U48_3.00_02_01_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0"]}],"supported_platforms":false,"supported_products":["U48"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-elx-lpfc-14.2.589.21-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"14.2.589.21"}],"installation_dependency":{},"name":"Red Hat Enterprise Linux 9 Server Update 2 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059293.exe","target_guids":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3330-3834-304b57584651"],"type_of_change":"1","version":"85032G00"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060557.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"type_of_change":"0","version":"4.7.1.0"}],"installation_dependency":{},"name":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":60,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-33071590027f"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","U44","A43","A42","A42","A43","U40","U41","U32","A42","H08","U50","H10","U50","I44","H08","U61","U60","A43","A47","U33","I43","I42","U39","U40","U34","U30","U64","A48","U34","U47","U47","U56","A40","A46","H10","U46","U31","H10","U46","U48","U39","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_40_1000-MCX653105A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30069","Version":"20.40.1000"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"20_40_1000-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"type_of_change":"1","version":"20.40.1000"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","A42","U58","A55","U50","U50","U54","U63","A43","A47","U54","U58","A48","U47","U47","U47","U47","A55","A40","A56","A46","U46","U46","U46","U62","U59","U58"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056786.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"type_of_change":"1","version":"13.0.16.0"}],"installation_dependency":{},"name":"Intel i350 Driver for Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A42","A55","U56","U54","A56","U65","H10","H08","A55","H08","U54","U61","U58","U63","02020001","03020102","U54","U60","03030201","U59","U65","03020101","A56","U58","H10","H10","H09","U62","U63","U58"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM3_V1.24.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd181e51629e","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052311.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd181e51629e"],"type_of_change":"1","version":"1.24"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online Flash Component for Windows x64 - Gen10Plus UBM3 Backplane PIC Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A43","A43","A43","A42","A42","U50","U46","U46","U61","A42","02020001","U60"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.3006"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.3006"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hca-mellanox-vpi-connectx4-1.0.15-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.15"}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","03020102","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055315.zip","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP055315","version":"HPD4.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB2000JFDSL and MB4000JFDSN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit-14.2.589.11-1.rhel8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"0","version":"14.2.589.11"}],"installation_dependency":{},"name":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters for Red Hat Enterprise Linux 8 Server","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-smartarray-f36d4ef431-0.39-5.1.x86_64.rpm","target_guids":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"type_of_change":"1","version":"0.39"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U50","U50"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPK2"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPK2"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059284.exe","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPK2"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) -  MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3054-3630-3430-304b57484145","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3130-3630-304b57484143"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8b26d1ef02-HPD2-7.1.x86_64.rpm","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304a57525444"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-aef2a690c9-HPG5-9.1.x86_64.rpm","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"1","version":"HPG5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3130-3932-3047574a5048","4d2340a5-304b-3030-3234-3047574b564b","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3330-3834-3047574a504b","4d2340a5-304b-3030-3438-3047574a504e","562340a5-304b-3030-3438-3047574a5045","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3030-3936-3047574a5046"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059315.zip","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP059315","version":"HPK3.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055329.zip","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP055329","version":"HPD4.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB6000JVYZD and MB4000JVYZC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304a56595a43","002340a5-4d00-3642-3030-304a56595a44"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM6_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM6_V1.04.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18369cdcc9","Version":"1.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056325.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd18369cdcc9"],"type_of_change":"1","version":"1.04"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online Flash Component for Windows x64 - Gen10Plus UBM6 Backplane PIC Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":true,"supported_products":["U30","A43","A43","A42","A42","U46","U46","U32"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058584.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4","20a6e8e4-bf33-4c71-a6bf-d9ec20128a07"],"type_of_change":"1","version":"2024.04.01","vib_list":[{"name":"ssacli2","version":"6.30.8.0-8.0.0.20143090.oem"}]}],"installation_dependency":{},"name":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 8.0 for Gen10/Gen10 Plus/Gen11 Controllers","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["U27","P95","A43","A43","U54","U40","U41","U12","U13","U32","Carbondale14","U14","U14","U25","Carbondale14","U19","A47","U33","U54","I45","A48","O42","U58","U38","U38","U38","U38","U38","U65","A42","P85","A55","U23","U21","P89","I44","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U48","A41","A42","U17","U13","U24","U14","U51","U18","U18","I43","I42","U37","U18","U34","U57","U20","U20","A40","U47","U62","U63","U45","P86","U44","U43","A48","A42","I40","U65","A46","U46","U50","U22","U50","U54","U63","A43","U39","U40","U40","U58","P92","U34","U47","U47","U47","U58","U46","Carbondale14","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-3243fce9a0-HPG4-13.1.x86_64.rpm","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEBTP Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3642-3030-304745425450"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057488.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f161a38","20a6e8e4-bf33-4c71-a6bf-d9ec466b4ce5"],"type_of_change":"1","version":"2023.12.01","vib_list":[{"name":"vmware-storcli64","version":"007.2613.0000.0000-01"}]}],"installation_dependency":{},"name":"HPE MegaRAID Storage Administrator StorCLI for VMware7.0 (For Gen10P and Gen11 Controllers)","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U54","U65","U32","A42","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052940.exe","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a574b4755"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"fibreutils-4.2-1_rhel.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec33366d5a"],"type_of_change":"0","version":"4.2-1"}],"installation_dependency":{},"name":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -Red Hat Enterprise Linux (RHEL)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-22811590036a"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"22_39_1002-MCX623105AS-VDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30040","Version":"22.39.1002"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"22_39_1002-MCX623105AS-VDA_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"type_of_change":"1","version":"22.39.1002"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","A42","U58","A55","U50","U50","U54","U61","U63","A43","A47","U54","U58","A48","U47","U47","U47","U47","U56","A40","A56","A46","U46","A55","U46","U46","U62","U59","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055152.exe","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-c4355d15c4-4ICSHPK4-8.1.x86_64.rpm","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","12.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057468.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"type_of_change":"1","version":"7.726.1.0"}],"installation_dependency":{},"name":"HPE MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p Gen10P and Gen11 controller driver for Microsoft Windows 2022 edition","per_device_install_time_seconds":400,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U54","U65","U32","A42","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK7"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK7"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK7"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059364.exe","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK7"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD8"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055197.exe","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3630-304a57485048","452340a5-3048-3030-3930-304a5748504b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060559.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"type_of_change":"0","version":"4.7.1.0"}],"installation_dependency":{},"name":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2016 and 2019","per_device_install_time_seconds":60,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f"],"supported_operating_systems":[{"os":"Windows","version":["10.0","10.0","10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","H08","U50","H10","U50","I44","H08","U61","U60","A43","A47","I41","U33","I43","I42","U37","U39","U40","U36","U34","U30","U64","A48","U34","U47","U47","U56","A40","A46","H10","U46","U31","H10","U46","U48","U39","U31"]},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059935.zip","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04","vib_list":[{"name":"CP059935","version":"5.04.1-7.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U46","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058301.zip","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP058301","version":"HPG6.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055424.zip","target_guids":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP055424","version":"HPG1.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM2_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM2_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18de95518a","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052829.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd18de95518a"],"type_of_change":"1","version":"1.20"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online Flash Component for Windows x64 - Gen10Plus UBM2 Backplane PIC Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U61","A43","A43","U50","A43","U46","U46","I44","A42","U60"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u41-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U41"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052928.exe","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWFUV and EG001200JWFVA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a57465641","452340a5-3047-3030-3630-304a57465556"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"amsd-3.5.0-1803.47.sles15.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"0","version":"3.5.0"}],"installation_dependency":{},"name":"Agentless Management Service (iLO5, iLO 6) for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U54","A56","U40","U41","U32","A42","U65","U58","A55","U50","A45","I44","U58","U54","U61","U60","U63","A43","A47","I41","U33","I43","I42","U37","U24","I45","U34","U30","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U46","U46","U65","U62","U63","U58","U54"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-fa46c607d6-HPD5-3.1.x86_64.rpm","target_guids":["002340a5-4d00-314d-3030-304a464a5448"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MM1000JFJTH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-304a464a5448"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u40-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","6.0","11.0","15.0","9.0","8.0"]}],"supported_platforms":false,"supported_products":["U40","U40"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055115.exe","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42","452340a5-304f-3030-3430-304a57444b50","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3830-304a57444b56"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055421.zip","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP055421","version":"HPD2.6-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3330-3230-304a57444c42","4d2340a5-304f-3130-3630-304a57444c41","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3830-304a57444b56","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3430-304a57444b50"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-7fc5497116-HPD8-6.1.x86_64.rpm","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JFHMH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3830-304a46484d48"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U39_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U39","U39"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055306.zip","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"1","version":"HPG5","vib_list":[{"name":"CP055306","version":"HPG5.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB010000GWAYN and MB008000GWAYL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_3006-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.3006"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp057776.exe","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.0.10"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (Windows x64) for Mellanox Open Ethernet cards","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U32","A42","U50","U50","U61","A43","A47","U30","A48","U47","U47","U47","U47","U56","A46","U46","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP054407.zip","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP054407","version":"HPG6.2-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055314.zip","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP055314","version":"HPG6.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB2000GFEMH and MB4000GFEMK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304746454d4b","002340a5-4d00-3242-3030-304746454d48"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-4ba9615f90-HPD8-6.1.x86_64.rpm","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWTFD and MB012000JWTFC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d815900212","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee15900212","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef15900212","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d81590020c","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d615900230","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de15900230","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d715900211","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec15900211","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed15900211","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d71590020e","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Version":"228.1.111000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111000.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Version":"228.1.111000"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"bcm228.1.111000.Optimized.pup.fwpkg","target_guids":["a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16d615900230","a6b1a447-382a-5a4f-14e4-16de15900230","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"type_of_change":"1","version":"228.1.111000"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]}]}]},"name":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","12.0","15.0","7.0","9.0"]}],"supported_platforms":true,"supported_products":["U30","U64","U45","U34","U44","U43","U38","U38","U33","U26","U31","U37","U39","U40","U39","U41","U34","U32","U36","U31","U30"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056780.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"type_of_change":"1","version":"2023.09.00","vib_list":[{"name":"igbn","version":"1.11.2.0-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE Intel igbn Driver for VMware vSphere 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U54","U40","U41","U32","A42","U58","A55","O43","U56","U50","U58","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","03020101","A40","A56","A46","U58","U46","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDA"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDA"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDA"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDA"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDA"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057691.zip","target_guids":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"type_of_change":"1","version":"HPDA","vib_list":[{"name":"CP057691","version":"HPDA.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057012.zip","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.15","vib_list":[{"name":"CP057012","version":"5.15.6-8.0.0.20143090"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["422340a5-3939-4644-4237-342d07f65795"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["U30","U34","A43","A43","A40","A42","A43","P89","U46","A42","U46","U41","A42","U31","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059016.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"1","version":"228.0.121.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E Driver for Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c1159016d7","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U44","U43","U38","U38","03020101","U40","U41","U32","U30","O43","02020001","U33","03020102","U37","U39","U36","U34","U30","U34","A40","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD3"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD3"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD3"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD3"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8173816d98-HPD3-1.1.x86_64.rpm","target_guids":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"supported_operating_systems":[{"os":"Linux","version":["9.0","8.0","7.0","15.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-87b796d9ae-HPD4-1.1.x86_64.rpm","target_guids":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055133.exe","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-d3000-5.04-8.1.x86_64.rpm","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","12.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.09"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.09"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.09"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-qlogic-flq-1.23.50-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"1","version":"1.23.50"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0","15.0"]}],"supported_platforms":true,"supported_products":["A41","03020101","02020001","A40","03020102"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055153.exe","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPDA.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8a0371a425-HPDA-2.1.x86_64.rpm","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPDA"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JWXKH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304a57584b48"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.3006"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-open-mellanox-eth-mft-1.0.10-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.10"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"supported_operating_systems":[{"os":"Linux","version":["6.0","11.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U32","A42","U50","U50","U61","A43","A47","U30","A48","U47","U47","U47","U47","U56","A46","U46","U46","U46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058386.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15","20a6e8e4-bf33-4c71-a6bf-d9ece43a8459"],"type_of_change":"1","version":"2023.10.00","vib_list":[{"name":"icen","version":"1.12.5.0-1OEM.702.0.0.17630552"}]}],"installation_dependency":{},"name":"Intel icen Driver for VMware vSphere 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U40","U41","U32","A42","H08","U58","A55","O43","H10","U56","U50","U58","H08","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U54","U46","U46","H09","U48","U63","U26","U31","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"16_35_3006-MCX562A-ACA_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30052","Version":"16.35.3006"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"16_35_3006-MCX562A-ACA_Ax_Bx.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101715b30052"],"type_of_change":"1","version":"16.35.3006"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for \t Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30052"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A48","A43","A42","A42","A43","A42","U50","U50","A43","A47","A48","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U48"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056771.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"type_of_change":"1","version":"2.1.249.0"}],"installation_dependency":{},"name":"HPE Intel vxn Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-10ed103c211b","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U38","O43","02020001","A40","U33","03020102","03020101","U37","U40","U41","U32","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-ice-1.12.6-1.rhel9u0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.12.6-1"},{"name":"kmod-ice-1.12.6-1.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.12.6-1"},{"name":"kmod-ice-1.12.6-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.12.6-1"}],"installation_dependency":{},"name":"Intel ice Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-15938086000e"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U40","U41","U32","A42","H08","U58","A55","O43","H10","U56","U50","U58","H08","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U54","U46","U46","H09","U48","U63","U26","U31","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059508.exe","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A40"]},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"6.00"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"6.00"},{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059943.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"type_of_change":"1","version":"6.00"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052259.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"type_of_change":"1","version":"0.39"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U50"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U61_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U61_2.00_02_01_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000023c"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U61","FTP"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057467.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"type_of_change":"1","version":"7.726.1.0"}],"installation_dependency":{},"name":"HPE MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p Gen10P and Gen11 controller Driver for Microsoft Windows 2019 edition","per_device_install_time_seconds":400,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U54","U65","U32","A42","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3429.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3429.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3429.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3429.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3429.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3429.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-is-intel-1.29.0-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"1","version":"1.29.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"8.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"name":"Intel Online Firmware Upgrade Utility for Linux x86_64","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0","15.0"]}],"supported_platforms":true,"supported_products":["U65","A42","A55","03020101","U54","U65","A42","U58","A55","U50","U58","U54","U61","U57","U63","U59","A43","A47","02020001","03020102","U54","U64","A42","U62","U60","A48","03030201","U47","U47","U56","A56","A56","A46","U46","U46","U46","U48","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055188.exe","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757535256","562340a5-304b-3130-3932-304757535255","562340a5-304b-3030-3936-304757535254","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3234-304757535251"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.03"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.03"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.03"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"ilo5_303.fwpkg","target_guids":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"1","version":"3.03"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"name":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","U38","A43","U38","A42","A43","U40","U41","U32","A42","H08","O43","U40","U51","U50","A45","I44","H08","U61","U60","U39","A42","A43","A47","I41","H10","U33","H09","I43","I42","U37","U24","U38","U40","U36","U34","U30","U64","A48","U34","U47","U47","U47","U47","U56","A40","A46","H10","U46","U39","H10","U46","U48","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD2"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD2"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD2"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALFHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059085.exe","target_guids":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-059b8654a6-HPG3-7.1.x86_64.rpm","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304757444645"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"6.52"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"6.52"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"6.52"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"6.52"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"6.52"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"6.52"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"6.52"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp058429.exe","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"type_of_change":"1","version":"6.52"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"supported_operating_systems":[{"os":"Windows","version":["10.0","10.0","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","A40"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055250.zip","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP055250","version":"HPG6.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_40_1000-MCX653105A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30068","Version":"20.40.1000"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"20_40_1000-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"type_of_change":"1","version":"20.40.1000"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","A42","U58","A55","U50","U50","A43","A47","U54","U58","A48","U47","U47","U47","U47","A55","A40","A56","A46","U46","U46","U46","U59","U58"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"6.52"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"6.52"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"6.52"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"6.52"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"6.52"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"6.52"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor_6.52.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"6.52"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-smartarray-f7c07bdbbd-6.52-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"type_of_change":"1","version":"6.52"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","12.0","15.0","9.0"]}],"supported_platforms":true,"supported_products":["A41","A40"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055261.zip","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP055261","version":"HPG3.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304b-3130-3630-304757455048","452340a5-304b-3030-3830-304757455046","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3230-304757455044"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059286.exe","target_guids":["002340a5-4d00-314d-3030-304a464a5448"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-304a464a5448"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.24"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.24"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","target_guids":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"type_of_change":"1","version":"1.24"}],"installation_dependency":{},"name":"Firmware Package - Gen10 NVMe Backplane PIC Firmware","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["00000000-0000-0000-0000-00004e564d65"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0","7.0","15.0","12.0","10.0.20317","10.0.17600.18999","10.0.14393.17599","9.0","8.0"]}],"supported_platforms":false,"supported_products":["U30","U45","U34","U38","U38","I41","A43","A40","I43","I42","U37","U40","U41","U32","U36","U34"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA2_SD_4p30_PLDMoMCTP_8001AF27.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"4.30"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_E810_XXVDA2_SD_4p30_PLDMoMCTP_8001AF27.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-159b80860003"],"type_of_change":"1","version":"4.30"}],"installation_dependency":{},"name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159b80860003"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","U65","H10","H08","A55","A42","U50","H08","U54","U61","U58","U63","A43","A47","U54","U60","A48","U57","U59","U47","U47","A43","A56","A56","U58","H10","U46","H10","U46","H09","U62","U63","U58"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v3.00 (01/26/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-a42-3.00_2024_01_26-2.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A42","A42","A42"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060558.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"type_of_change":"0","version":"4.7.1.0"}],"installation_dependency":{},"name":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2016 and 2019","per_device_install_time_seconds":60,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-33071590027f"],"supported_operating_systems":[{"os":"Windows","version":["10.0","10.0","10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","H08","U50","H10","U50","I44","H08","U61","U60","A43","A47","I41","U33","I43","I42","U37","U39","U40","U36","U34","U30","U64","A48","U34","U47","U47","U56","A40","A46","H10","U46","U31","H10","U46","U48","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059038.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"type_of_change":"1","version":"221.0.5.0"}],"installation_dependency":{},"name":"Broadcom NX1 1Gb Driver for Windows Server x64 Editions","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U65","U43","A43","U62","A42","U56","U54","A56","U65","A42","A46","A55","U50","U54","U63","U59","A43","U54","U40","U58","U65","U47","U47","U47","A43","A56","U58","A55","U46","U46","U48","U63","U58"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059390.exe","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U33"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG5"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG5"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG5"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-0a7010918e-HPG5-2.1.x86_64.rpm","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD2"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b04df66fe9-HPD2-4.1.x86_64.rpm","target_guids":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JYDNF and MB008000JYDPC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059374.exe","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U30"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u44-3.00_2024_02_01-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","15.0","12.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U44"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK7"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK7"},{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK7"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173x00HPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059256.exe","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154","4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"1","version":"HPK7"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KWZQR, VO003840KWZQT, MO001600KWZQP and MO003200KWZQQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3330-3834-304b575a5154","562340a5-304f-3130-3932-304b575a5152","4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052939.exe","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWFVK and MB006000JWFVL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4T adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXV4T_O_SEC_4p31_PLDMoMCTP_8001AF2A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000e","Version":"4.31"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_E810_XXV4T_O_SEC_4p31_PLDMoMCTP_8001AF2A.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-15938086000e"],"type_of_change":"1","version":"4.31"}],"installation_dependency":{},"name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter ","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-15938086000e"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0","15.0"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","U65","H10","H08","A55","A42","U50","H08","U54","U61","U58","U63","A43","A47","U54","U60","A48","U57","U59","U47","U47","A43","A56","A56","U58","H10","U46","H10","U46","H09","U62","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059337.exe","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"1","version":"HPK5"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3030-3936-3052584b5243","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3130-3932-3052584b5248","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-304f-3330-3834-3052584b524b","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3030-3936-3052584b5242","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3130-3932-3052584b5244","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3330-3834-3052584b5245","Version":"HPD5"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","target_guids":["4d2340a5-304f-3030-3936-3052584b5243","4d2340a5-304f-3130-3932-3052584b5248","4d2340a5-304f-3330-3834-3052584b524b","562340a5-304f-3030-3936-3052584b5242","562340a5-304f-3130-3932-3052584b5244","562340a5-304f-3330-3834-3052584b5245"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3030-3936-3052584b5243","4d2340a5-304f-3130-3932-3052584b5248","4d2340a5-304f-3330-3834-3052584b524b","562340a5-304f-3030-3936-3052584b5242","562340a5-304f-3130-3932-3052584b5244","562340a5-304f-3330-3834-3052584b5245"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059279.exe","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"1","version":"HPD7"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314f-3630-304a56595052","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4500-304b-3830-304a5659504e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055211.exe","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304757554441"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7725Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7725Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7725Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7725Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7725Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7725Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7725Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7725Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7725Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7725Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-951aefd63e-MPK7725Q-1.1.x86_64.rpm","target_guids":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"type_of_change":"1","version":"MPK7725Q"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053382.zip","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP053382","version":"HPG1.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG2"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-3496cc4743-HPG2-1.1.x86_64.rpm","target_guids":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"type_of_change":"1","version":"HPG2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-aa9e289524-HPD5-7.1.x86_64.rpm","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWEBH and EG000300JWEBF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57454246","452340a5-3047-3030-3630-304a57454248"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD3"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD3"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD3"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD3"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059883.exe","target_guids":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055304.zip","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP055304","version":"HPG8.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWBXQ and MB008000GWBYL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059329.zip","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP059329","version":"HPD8.6-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VO007680JWCNK and VO015300JWCNL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3330-304a57434e4c","562340a5-304f-3730-3638-304a57434e4b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058390.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7b103d04"],"type_of_change":"1","version":"1.13.242.0"}],"installation_dependency":{},"name":"Intel icea Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","A56","U65","H10","H08","U58","A55","A42","U50","U58","H08","U54","U61","U57","U63","A43","02020001","03020102","U54","U60","A43","03030201","U59","U47","U47","03020101","A56","A46","H10","U46","H10","U46","H09","U62","U63","U58"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060120.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f36672a","20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b"],"type_of_change":"1","version":"5.0.0.0"}],"installation_dependency":{},"name":"Integrated Smart Update Tools for Windows x64","per_device_install_time_seconds":150,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","A40","U40","U39","U41","U32","A42","U65","U46","A55","U56","U50","I44","U58","U61","U60","U63","A43","A47","U33","I43","I42","U37","I45","U34","U30","U64","A48","U34","U59","U47","U47","A55","A56","A56","A46","U46","U46","U65","U48","U63","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058993.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"qedrntv","version":"3.70.50.0-1OEM.700.1.0.15843807"},{"name":"qedf","version":"2.74.1.0-1OEM.700.1.0.15843807"},{"name":"qedentv","version":"3.70.52.0-1OEM.700.1.0.15843807"},{"name":"qedi","version":"2.74.1.0-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U30","O43","U40","U56","U50","U61","U60","A43","A47","02020001","U33","03020102","U37","U39","U36","U34","U30","A48","U34","U47","U47","U47","03020101","A40","A46","U46","U31","U46","U48","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK77H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK77H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK77H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK77H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK77H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK77H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK77H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK77H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK77H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK77H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK77H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-e320db791d-MPK77H5Q-1.1.x86_64.rpm","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"type_of_change":"1","version":"MPK77H5Q"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3830-3048d90154e8"],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","12.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055687.exe","target_guids":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.03"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.03"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_303.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.03"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-ilo5-3.03-1.1.x86_64.rpm","target_guids":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"1","version":"3.03"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","U38","A43","U38","A42","A43","U40","U41","U32","A42","H08","O43","U40","U51","U50","A45","I44","H08","U61","U60","U39","A42","A43","A47","I41","H10","U33","H09","I43","I42","U37","U24","U38","U40","U36","U34","U30","U64","A48","U34","U47","U47","U47","U47","U56","A40","A46","H10","U46","U39","H10","U46","U48","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052135.exe","target_guids":["002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG9"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MM2000GEFRA Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-324d-3030-304745465241"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055097.exe","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b85516c7d2-HPD3-10.1.x86_64.rpm","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"MRStorageAdministrator-008.006.018.000-00.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"type_of_change":"1","version":"8.6.18.0"}],"installation_dependency":{},"name":"HPE MegaRAID Storage Administrator for Linux 64-bit (HPE MRSA for Gen10P and Gen11 Controllers)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":true,"supported_products":["A43","A42","A42","U54","U65","U32","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_33_1048-872726-B21_Ax_Bx-UEFI-14.26.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.33.1048"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_33_1048-879482-B21_Ax-UEFI-14.26.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.33.1048"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053228.zip","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP053228","version":"1.0.5-7.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (ESXi 7.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["U38","U38","A43","A42","A42","A43","U40","U32","A42","U50","U50","U61","A43","A47","U37","A48","U47","U47","U47","U47","U56","A46","U46","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055181.exe","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK007680GWSXN  Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3730-3638-30475753584e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059327.exe","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"1","version":"HPK3"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-aaf1014ede-HPD3-7.1.x86_64.rpm","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304a57444644"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-megaraid_sas-07.726.03.00_rhel9u2-1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.726.03.00"},{"name":"kmod-megaraid_sas-07.726.03.00_rhel9u1-1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.726.03.00"}],"installation_dependency":{},"name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p Gen11 controller Driver for 64-bit Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","U54","U65","U32","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055196.exe","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000GWXKK Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304757584b4b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":800,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":800,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052255.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"1","version":"1.00"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Backplane Expander Firmware","per_device_install_time_seconds":800,"reboot_required":"no","support_url":"","supported_devices":["422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-1000-00cf1590022c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U38","U38","U38"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK5"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK5"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK5"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK5"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK5"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK5"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-a27c95663d-HPK5-1.1.x86_64.rpm","target_guids":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"type_of_change":"1","version":"HPK5"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43","562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"mlnx-ofa_kernel-kmp-default-23.10_k5.14.21_150500.53-OFED.23.10.1.1.9.1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"23.10-1.1.9.1"},{"name":"mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"23.10-1.1.9.1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"name":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ConnectX-4, ConnectX-5 and ConnectX-6 Driver for SUSE LINUX Enterprise Server 15 SP5 (AMD64/EM64T)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U65","U43","U38","U38","A43","U65","A42","A42","A43","U45","A56","U40","U39","U41","U32","A42","U58","U25","A55","U21","U50","U56","U50","U54","U61","U58","U63","U59","A43","A47","02020001","U54","P89","P89","U37","U36","U34","U30","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U46","U54","U46","U46","A55","U62","U63","U58","U31","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_40_1000-MCX653435A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900347","Version":"20.40.1000"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"20_40_1000-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900347"],"type_of_change":"1","version":"20.40.1000"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b15900347"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","A42","U58","A55","U50","U50","A43","A47","U54","U58","A48","U47","U47","U47","U47","A55","A40","A56","A46","U46","U46","U46","U59","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059277.exe","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"1","version":"HPD6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEML and MB4000JFEMN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053847.zip","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP053847","version":"HPD4.4-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3631-3030-304a575a4845","4d2340a5-3042-3431-3030-304a575a4843"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u32-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U32"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059708.zip","target_guids":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP059708","version":"HPG4.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055114.exe","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048","452340a5-304b-3030-3230-304757455044"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM4_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM4_V1.24.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18f636f994","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053175.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd18f636f994"],"type_of_change":"1","version":"1.24"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online Flash Component for Windows x64 - Gen10Plus UBM4 Backplane PIC Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A43","A43","A42","A42","U46","U46"]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM1_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM1_V1.46.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1816036156","Version":"1.46"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053174.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd1816036156"],"type_of_change":"1","version":"1.46"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online Flash Component for Windows x64 - Gen10Plus UBM1 Backplane PIC Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U47","U47","A46","A43","I44","A42"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U64_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.00 (02/01/2024)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U64_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.00 (02/01/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059522.exe","target_guids":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U64","FTP"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059705.zip","target_guids":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP059705","version":"HPD4.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp054534.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb135dd88"],"type_of_change":"0","version":"1.0.0.1"}],"installation_dependency":{},"name":"HPE Emulex Fibre Channel Smart SAN Enablement Kit for Host Bus Adapters for Microsoft Windows Server 2016/2019 (x86_64)","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","SPP","A42","A43","U40","U39","U41","U32","A42","U50","A42","A43","A47","U33","U37","U34","U30","A48","U34","U47","U47","A40","A46","U46","U48","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-bnxt_en-1.10.2-228.0.133.0.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"1","version":"1.10.2-228.0.133.0"},{"name":"kmod-bnxt_en-1.10.2-228.0.133.0.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"1","version":"1.10.2-228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-6ec35faf90-HPD6-6.1.x86_64.rpm","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWAYK and MB008000JWAYH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059371.exe","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U32"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058384.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"type_of_change":"1","version":"2023.10.00","vib_list":[{"name":"i40en","version":"2.5.2.0-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE Intel i40en Driver for VMware vSphere 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U44","U43","U38","U38","A42","A43","U41","U32","A42","U56","U61","U60","A43","A47","02020001","U33","03020102","U37","U64","U36","U34","U30","A48","U34","U47","U47","03020101","A40","A46","U46","U46","U48","U31"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.5"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.5"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3437.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-intel-1.29.0-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-37D215900218"],"type_of_change":"1","version":"1.29.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccba99d79","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]}]}]},"name":"HPE Intel Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen9 and Gen10 server series Only.","per_device_install_time_seconds":1800,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-37d215900218"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0","15.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058380.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"type_of_change":"1","version":"1.18.367.0"}],"installation_dependency":{},"name":"HPE Intel i40ea Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055176.exe","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-304757485255","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","562340a5-304b-3030-3234-304757455a42","4d2340a5-304b-3030-3438-304757455a48","562340a5-304b-3030-3438-304757455a43","4d2340a5-304b-3030-3936-304757455a4b","562340a5-304b-3030-3936-304757455a44"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-3042-3630-3030-304759444e4c","Version":"HPG1"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-3042-3830-3030-304759445045","Version":"HPG1"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-3042-3031-3030-304759444e4e","Version":"HPG1"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Seagate_CimarronBP_SCIMARBPETG1.fwpkg","target_guids":["4d2340a5-3042-3630-3030-304759444e4c","4d2340a5-3042-3830-3030-304759445045","4d2340a5-3042-3031-3030-304759444e4e"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - MB006000GYDNL, MB008000GYDPE and MB010000GYDNN","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304759444e4c","4d2340a5-3042-3830-3030-304759445045","4d2340a5-3042-3031-3030-304759444e4e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"fibreutils-4.2-1_sles.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec33366d5a"],"type_of_change":"0","version":"4.2-1"}],"installation_dependency":{},"name":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -SuSE Linux Enterprise Server(SLES)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367"],"supported_operating_systems":[{"os":"Linux","version":["15.0","12.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059336.zip","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"1","version":"4ICRHPK3","vib_list":[{"name":"CP059336","version":"4ICRHPK3.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3630-3430-304b57565641","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3330-3230-304b57565556","562340a5-304f-3230-3030-304b57565643","4d2340a5-304f-3130-3630-304b57565555"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR416i-p_Gen10P_52.26.3-5379_A.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.26.3-5379"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_MR416i-p_Gen10P_52.26.3-5379_A.fwpkg","target_guids":["a6b1a447-382a-5a4f-1000-10e215900293"],"type_of_change":"1","version":"52.26.3-5379"}],"installation_dependency":{},"name":"Firmware Package - HPE MR416i-p Gen10 Plus Tri Mode Controller ","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900293"],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","10.0.14393.17599","8.0","15.0","12.0","10.0.20317","7.0","9.0","8.0"]}],"supported_platforms":false,"supported_products":["U46","A43","A43","A42","A42","U46","U46","U61","U60"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD3"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD3"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD3"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD3"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD3"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD3"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD3"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD3"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD3"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD3"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD3"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059285.exe","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","562340a5-304f-3531-3330-305058444256","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-5bf9355926-HPG3-11.1.x86_64.rpm","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048","452340a5-304b-3030-3230-304757455044"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059292.exe","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-304b57564d56","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3130-3932-304b57564d54"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG5"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052426.exe","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYZB and MB4000GVYZA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304756595a41","002340a5-4d00-3642-3030-304756595a42"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1013"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1013"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1013"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1013"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.2.14.1013"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.2.14.1013"}]},"MinimumActiveVersion":"1.0.14.1063","Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_NS204i_Gen10P_Gen11_1.2.14.1013_A.fwpkg","target_guids":["a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310"],"type_of_change":"1","version":"1.2.14.1013"}],"installation_dependency":{},"name":"Firmware Package - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-224115900310","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f"],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","8.0","15.0","10.0.20317","8.0","9.0","22.04","10.0.14393.17599","7.0","12.0"]}],"supported_platforms":false,"supported_products":["U65","A43","A42","A42","A43","U54","U65","U41","U32","A42","A46","U46","A55","H10","U50","I44","U54","U61","U58","U63","A43","A47","U33","U54","U60","U39","U40","I45","U34","U30","A48","U34","U59","U47","U47","A55","A56","A56","U58","H10","U46","H10","U46","U48","U63","U58"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"A47_3.00_01_26_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A47"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTEDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDC"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTEDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDC"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057699.exe","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPDC"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EH000600JWCPF and EH000900JWCPH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_40_1000-P06154-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.40.1000"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_40_1000-P06250-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.40.1000"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_40_1000-P06251-B21_Ax-UEFI-14.33.10-FlexBoot-3.7.300.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.40.1000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp060194.exe","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.0.9"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on Windows x86_64 platform","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","03020102","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U50_2.00_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.00 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059651.exe","target_guids":["00000000-0000-0000-0000-00000000022b"],"type_of_change":"1","version":"2.00_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U50"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.10 (02/22/2024)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.10 (02/22/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u34-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U34","U34"]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for MicroServerv2 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SC_MicroServerv2GEN10Plus_ME_06.00.03.604.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"SC_MicroServerv2GEN10Plus_ME_06.00.03.604.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2 Servers","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":true,"supported_products":["U64","FTP"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058433.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c"],"type_of_change":"1","version":"2024.04.01","vib_list":[{"name":"smartpqi","version":"70.4600.0.115-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 7.0 (Driver Component).","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U65","U65","U38","U38","A43","U62","A42","A42","A43","U54","A56","U40","U41","U32","A42","U58","A55","O43","U50","I44","U58","U54","U61","U60","U63","A43","A47","U54","U33","I43","I42","U37","U40","U36","I45","U34","U30","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U31","U46","U48","U63","U58","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b460823f70-HPG3-6.1.x86_64.rpm","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK007680GWSXN Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3730-3638-30475753584e"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"},{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-7677644a25-HPG3-11.1.x86_64.rpm","target_guids":["4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-304757434642","4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-f693ccc138-HPG3-8.1.x86_64.rpm","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3330-3834-304757535346","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3030-3438-304757535343"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059441.exe","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG7"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-a40-3.00_2024_01_26-2.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A40"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-c993b31232-HPG6-3.1.x86_64.rpm","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_4p30_NCSIwPLDMoMCTP_8001AF23.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"4.30"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_E810_XXVDA2_SD_OCP_4p30_NCSIwPLDMoMCTP_8001AF23.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-159b80860005"],"type_of_change":"1","version":"4.30"}],"installation_dependency":{},"name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159b80860005"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","U65","H10","H08","A55","A42","U50","H08","U54","U61","U58","U63","A43","A47","U54","U60","A48","U57","U59","U47","U47","A43","A56","A56","U58","H10","U46","H10","U46","H09","U62","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055357.zip","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP055357","version":"HPD9.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-5600-334f-3834-304a46444841","002340a5-5600-314f-3932-304a46444756","002340a5-5600-304f-3936-304a46444755","002340a5-5600-304f-3438-304a46444754"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"hp-iavf-kmp-default-4.9.1_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"1","version":"4.9.1-1"},{"name":"hp-iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"1","version":"4.9.1-1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"name":"Linux","value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.3","description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"name":"Linux","value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.3","description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component"}]}]}]},"name":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U40","U41","U32","A42","H08","U58","A55","O43","H10","U56","U50","U58","H08","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U54","U46","U46","H09","U48","U63","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.rhel9u3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"23.10-1.1.9.1"},{"name":"mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.rhel9u3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"23.10-1.1.9.1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"name":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ConnectX-4, ConnectX-5 and ConnectX-6 Driver for Red Hat Enterprise Linux 9 Update 3 (x86_64)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U65","U43","U38","U38","A43","U65","A42","A42","A43","U45","A56","U40","U39","U41","U32","A42","U58","U25","A55","U21","U50","U56","U50","U54","U61","U58","U63","U59","A43","A47","02020001","U54","P89","P89","U37","U36","U34","U30","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U46","U54","U46","U46","A55","U62","U63","U58","U31","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR216i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.26.3.5379"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP060396.zip","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032b"],"type_of_change":"2","version":"52.26.3.5379","vib_list":[{"name":"CP060396","version":"52.26.3.5379.5-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Controller Firmware Flash for ESXi7.0 and 8.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e21590032b"],"supported_operating_systems":[{"os":"VMware","version":["8.0","7.0"]}],"supported_platforms":false,"supported_products":["U30","A43","A43","A42","A42","U46","SPP","U46","U61","U32","U60"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp054435.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdc79ba4d"],"type_of_change":"0","version":"1.0.0.1"}],"installation_dependency":{},"name":"HPE QLogic Smart SAN Enablement Kit for Fibre Channel Host Bus Adapter for Microsoft Windows Server 2016/2019 (x86_64)","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","SPP","A42","A43","U40","U39","U41","U32","A42","U50","A42","A43","A47","U33","U37","U34","U30","A48","U34","U47","U47","A40","A46","U46","U48","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-3.noarch.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1"],"type_of_change":"1","version":"6.0.0.1-3"}],"installation_dependency":{},"name":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter for Linux","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Linux","version":["12.0","8.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055187.exe","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3330-3834-304757535346","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3030-3438-304757535343"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK5"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK5"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK5"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059361.exe","target_guids":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"type_of_change":"1","version":"GPK5"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp059617.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.603"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059620.exe","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000101"],"type_of_change":"0","version":"04.04.04.603"}],"installation_dependency":{},"name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0","10.0","10.0.20317"]}],"supported_platforms":true,"supported_products":["U47","U47","U56","H10","U50","U46","H10","U46","I44","H10"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053464.zip","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP053464","version":"HPD5.2-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWEBH and EG000300JWEBF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57454246","452340a5-3047-3030-3630-304a57454248"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059383.exe","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U41"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"ssacli-6.30-8.0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"type_of_change":"1","version":"6.30.8.0"}],"installation_dependency":{},"name":"Smart Storage Administrator (SSA) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","8.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["U27","P95","A43","A43","U54","U40","U41","U12","U13","U32","Carbondale14","U14","U14","U25","Carbondale14","U19","A47","U33","U54","I45","A48","O42","U58","U39","U38","U38","U38","U38","U38","U65","A42","P85","A55","U23","U21","P89","I44","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U31","U31","A42","U14","U13","U24","U40","U18","U18","I43","I42","U37","U18","U34","U57","U20","U20","A40","U62","U63","U17","P86","A42","I40","U65","A46","U22","U50","U54","U63","A43","U39","U40","U36","U58","P92","U34","U47","U47","U58","Carbondale14","U46","U46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-megaraid_sas-07.726.03.00_rhel8u7-1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.726.03.00"},{"name":"kmod-megaraid_sas-07.726.03.00_rhel8u8-1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.726.03.00"}],"installation_dependency":{},"name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p Gen11 controller Driver for 64-bit Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","U54","U65","U32","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-e4f147cdd2-HPG4-2.1.x86_64.rpm","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000GWXKK Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304757584b4b"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060556.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"type_of_change":"0","version":"4.7.1.0"}],"installation_dependency":{},"name":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":60,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","U44","A43","A42","A42","A43","U40","U41","U32","A42","H08","U50","H10","U50","I44","H08","U61","U60","A43","A47","U33","I43","I42","U39","U40","U34","U30","U64","A48","U34","U47","U47","U56","A40","A46","H10","U46","U31","H10","U46","U48","U39","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE NV60100M 100Gb 2p Strg Offload Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"22_38_1002-R8M41-63001_Ax_header.pldm.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d1590037d","Version":"22.38.1002"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"22_38_1002-R8M41-63001_Ax_header.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101d1590037d"],"type_of_change":"1","version":"22.38.1002"}],"installation_dependency":{},"name":"Mellanox Firmware Package(FWPKG) for HPE NV60100M 100Gb 2-port Storage Offload Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101d1590037d"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["U59","A56","U63","A43","A55","A56","A42","U58","U50","U54","U46","U54","A55","U46","U57","U58"]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp059609.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059610.exe","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["FTP","U60"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059318.zip","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP059318","version":"HPD7.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314f-3630-304a56595052","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4500-304b-3830-304a5659504e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055269.zip","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP055269","version":"HPD8.5-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3230-304a45544b43","002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG5"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-0a7d4aa47f-HPG5-2.1.x86_64.rpm","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GVYZB and MB4000GVYZA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304756595a41","002340a5-4d00-3642-3030-304756595a42"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059302.exe","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"1","version":"4ICRHPK3"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3630-3430-304b57565641","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3330-3230-304b57565556","562340a5-304f-3230-3030-304b57565643","4d2340a5-304f-3130-3630-304b57565555"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060561.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"1","version":"10.1.19006.8299"}],"installation_dependency":{},"name":"Identifiers for Intel Xeon Scalable Processors (Third Generation) for Microsoft Windows","per_device_install_time_seconds":3600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0","10.0","10.0.20317"]}],"supported_platforms":true,"supported_products":["U47","U47","U56","U50","H10","U50","U46","H10","U46","I44","H10"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U32_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U32"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"228.1.111000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"228.1.111000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"228.1.111000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"228.1.111000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"228.1.111000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"228.1.111000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"228.1.111000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"228.1.111000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-bcm-nxe-1.19.0-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"type_of_change":"1","version":"1.19.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107000","description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active"}]}]}]},"name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0","15.0"]}],"supported_platforms":true,"supported_products":["A41","03030201","02020001","A40","03020102","03020101"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058358.exe","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JXLBA and MB018000JXLAU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.10 (02/22/2024)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.10 (02/22/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059399.exe","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U34","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060118.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf4d60f54"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"sut","version":"701.5.0.0.16-1OEM.701.0.0.16850804"}]}],"installation_dependency":{},"name":"Integrated Smart Update Tools 5.0.0 for ESXi 7.0","per_device_install_time_seconds":150,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","A40","U40","U39","U41","U32","A42","U65","U58","U46","A55","U56","U50","I44","U58","U54","U61","U60","U63","A43","A47","U54","U33","I43","I42","U37","U62","I45","U34","U30","U64","A48","U57","U34","U59","U47","U47","A55","A56","A56","A46","U54","U46","U46","U65","U48","U63","U58","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055160.exe","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEBTP Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3642-3030-304745425450"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD8"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP054157.zip","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP054157","version":"HPD8.1-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPK and EH000600JWHPH   Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053446.zip","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP053446","version":"HPG4.2-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000GWXKK Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304757584b4b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055339.zip","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP055339","version":"HPD5.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3330-3834-304a57465756"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-9ad359dac1-HPDB-1.1.x86_64.rpm","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPDB"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp057556.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.913"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-dl20ml30gen10sps-05.01.04.913-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.913"}],"installation_dependency":{},"name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U44","U43"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053032.exe","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB2000GFEMH and MB4000GFEMK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053422.zip","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP053422","version":"HPD3.2-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB012000JWDFD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304a57444644"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055358.zip","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP055358","version":"HPD9.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c","002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-tg3-3.139k-1.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"1","version":"3.139k-1"},{"name":"kmod-tg3-3.139k-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"1","version":"3.139k-1"}],"installation_dependency":{},"name":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U65","U58","A55","U50","U40","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U56","U34","U47","U47","U47","03020101","A40","A56","A46","U65","A55","U46","U39","U46","U48","U63","U58","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8ed8893abd-HPD9-8.1.x86_64.rpm","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-5600-334f-3834-304a46444841","002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"6.00"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"6.00"},{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059941.zip","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"type_of_change":"1","version":"6.00","vib_list":[{"name":"CP059941","version":"6.00.1-7.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U46","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055308.zip","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP055308","version":"HPG2.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-iavf-4.9.1-1.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"1","version":"4.9.1-1"},{"name":"kmod-hp-iavf-4.9.1-1.rhel8u6.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"1","version":"4.9.1-1"},{"name":"kmod-hp-iavf-4.9.1-1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"1","version":"4.9.1-1"}],"installation_dependency":{},"name":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 8","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U40","U41","U32","A42","H08","U58","A55","O43","H10","U56","U50","U58","H08","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U54","U46","U46","H09","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK5"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK5"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK5"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059360.zip","target_guids":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"type_of_change":"1","version":"GPK5","vib_list":[{"name":"CP059360","version":"GPK5.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"tg3-kmp-default-3.139k_k5.14.21_150500.53-2.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"1","version":"3.139k-2"},{"name":"tg3-kmp-default-3.139k_k5.14.21_150400.22-2.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"1","version":"3.139k-2"}],"installation_dependency":{},"name":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U65","U58","A55","U50","U40","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U56","U34","U47","U47","U47","03020101","A40","A56","A46","U65","A55","U46","U39","U46","U48","U63","U58","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-f6d00bd17e-HPD4-6.1.x86_64.rpm","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - MB004000JWFVK and MB006000JWFVL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-kernel-mft-mlnx-4.26.1-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"0","version":"4.26.1-3"},{"name":"mft-4.26.1-3.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"0","version":"4.26.1-3"}],"installation_dependency":{},"name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 2 (x86_64)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U43","U38","U38","A43","A42","A42","A43","U45","U40","U39","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","U37","U36","U34","U30","A48","U34","03030201","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400KYDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IASHPK4.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304b59444b56","Version":"HPK4"},{"DeviceName":"EO000800KYDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IASHPK4.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304b59444c41","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059258.zip","target_guids":["452340a5-304f-3030-3430-304b59444b56","452340a5-304f-3030-3830-304b59444c41"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP059258","version":"HPK4.6-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - EO000400KYDKV and EO000800KYDLA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304f-3030-3830-304b59444c41","452340a5-304f-3030-3430-304b59444b56"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-7a1edae8e7-HPG1-3.1.x86_64.rpm","target_guids":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for ML30 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SC_ML30GEN10Plus_ME_06.00.03.604.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"SC_ML30GEN10Plus_ME_06.00.03.604.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus Servers","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":true,"supported_products":["U61","FTP"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002db","Version":"03.01.23.072"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f1590032e","Version":"03.01.23.072"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900381","Version":"03.01.23.072"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002dc","Version":"03.01.23.072"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900294","Version":"03.01.23.072"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_SR416_SR932_Gen10P_Gen11_03.01.23.072_A.fwpkg","target_guids":["a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"type_of_change":"1","version":"03.01.23.072"}],"installation_dependency":{},"name":"Firmware Package - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","8.0","15.0","12.0","10.0.20317","9.0","8.0","10.0.14393.17599","7.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","U54","U65","A55","U50","U58","U54","U57","U63","A43","U54","I45","U60","U59","U65","A55","A56","A56","U46","U46","U62","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-c5cd837c29-HPD3-6.1.x86_64.rpm","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - EG000300JWFVB Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57465642"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SPSGen10Plus_04.04.04.603.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.603"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"SPSGen10Plus_04.04.04.603.fwpkg","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000101"],"type_of_change":"0","version":"04.04.04.603"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0","8.0"]}],"supported_platforms":true,"supported_products":["U46","U47","U47","U56","U36","H10","U50","U46","H10","U46","I44","H10"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"netxtreme2-kmp-default-7.15.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"1","version":"7.15.17-1"},{"name":"netxtreme2-kmp-default-7.15.17_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"1","version":"7.15.17-1"}],"installation_dependency":{},"name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16af103c1933","a6b1a447-382a-5a4f-14e4-16ad103c1917","a6b1a447-382a-5a4f-14e4-16ae103c3382","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","U40","U41","U32","U30","O43","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059859.exe","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U43"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058530.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0427da2e","20a6e8e4-bf33-4c71-a6bf-d9ec9f71a861","20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40"],"type_of_change":"1","version":"2023.09.13","vib_list":[{"name":"nmlx4-core","version":"3.19.70.2001-1OEM.700.1.0.15843807"},{"name":"nmlx4-en","version":"3.19.70.2001-1OEM.700.1.0.15843807"},{"name":"nmlx4-rdma","version":"3.19.70.2001-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"nmlx4_en Driver Component for VMware 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1003103c1777","a6b1a447-382a-5a4f-15b3-1003103c18cf","a6b1a447-382a-5a4f-15b3-1003103c18d6","a6b1a447-382a-5a4f-15b3-1003103c18cd","a6b1a447-382a-5a4f-15b3-1003103c18ce","a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["U13","A41","U17","P86","U38","U38","A43","A42","A42","A43","U45","U24","U40","U15","I38","U41","U12","U13","U32","A42","U14","U25","I36","P85","U21","U50","U19","U22","P89","U50","I39","U61","P99","I40","A43","A47","I40","I41","U47","I43","U14","P89","P89","U37","U15","U20","U36","U34","U30","I37","A48","P92","U34","U20","U47","U47","U47","I36","U56","A40","A46","U46","I42","U46","U46","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK7"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK7"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK7"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK7"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK7"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059368.zip","target_guids":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"type_of_change":"1","version":"GPK7","vib_list":[{"name":"CP059368","version":"GPK7.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c31355433"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059339.zip","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"1","version":"HPK5","vib_list":[{"name":"CP059339","version":"HPK5.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058382.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520"],"type_of_change":"1","version":"1.18.367.0"}],"installation_dependency":{},"name":"HPE Intel i40eb Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG2"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG2"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG2"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG2"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059885.zip","target_guids":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP059885","version":"HPG2.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE 100GbE 1p QSFP28 MCX515A-CCAT Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"16_35_3006-MCX515A-CCA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715900346","Version":"16.35.3006"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"16_35_3006-MCX515A-CCA_HPE_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101715900346"],"type_of_change":"1","version":"16.35.3006"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715900346"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","U45","U38","U38","A43","A42","A42","A43","U54","A56","U40","U41","U32","A42","U58","U25","A55","U50","U19","U22","U50","U54","U63","U39","A43","A47","P89","P89","U54","U34","U36","U34","U30","A48","U47","U47","U47","U47","A55","A40","A56","A46","U46","U46","U46","U59","U58","U39","U37"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTEDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDC"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTEDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDC"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-a05f29cef3-HPDC-2.1.x86_64.rpm","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPDC"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-805abb7e9c-85032G00-5.1.x86_64.rpm","target_guids":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85032G00"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"supported_operating_systems":[{"os":"Linux","version":["8.0","7.0","15.0","12.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020907.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.09.07"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020907.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.09.07"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020205.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.02.05"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020205.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.02.05"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020205.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.02.05"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020205.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.02.05"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020907.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.09.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020907.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.09.07"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058496.zip","target_guids":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2023.10.01","vib_list":[{"name":"CP058496","version":"2023.10.01.4-7.0.0.15843807"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.0.1-3","description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active"}]}]}]},"name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 8.0","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U46","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055200.exe","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055117.exe","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWFWK and MB002000GWFWL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"WDC-ParisD-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"WDC_ParisD_WparisdASFD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"4d2340a5-3042-3032-3030-304a584d5655","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"WDC_ParisD_WparisdASFD1.fwpkg","target_guids":["4d2340a5-3042-3032-3030-304a584d5655"],"type_of_change":"1","version":"HPD1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - MB020000JXMVU","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3032-3030-304a584d5655"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.17600.18999","10.0.14393.17599","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059002.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"qfle3i","version":"2.1.14.0-1OEM.700.1.0.15843807"},{"name":"qcnic","version":"2.0.66.0-1OEM.700.1.0.15843807"},{"name":"qfle3f","version":"2.1.33.0-1OEM.700.1.0.15843807"},{"name":"qfle3","version":"1.4.46.0-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","U40","U41","U32","U30","O43","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDA"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDA"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDA"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDA"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055733.zip","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"type_of_change":"1","version":"HPDA","vib_list":[{"name":"CP055733","version":"HPDA.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp059602.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-ml30gen10plus_me-06.00.03.604-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U61","FTP"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX631102 10/25GbE 2p SFP28 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"26_39_1002-MCX631102AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30012","Version":"26.39.1002"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"26_39_1002-MCX631102AS-ADA_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"type_of_change":"1","version":"26.39.1002"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","U65","A43","A42","A42","A43","U54","A56","U65","A42","U58","A55","U50","U50","U54","U61","U57","U63","A43","A47","U54","U58","A48","U63","U47","U47","U47","U47","U56","A40","A56","A46","U46","A55","U46","U46","U62","U59","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053419.zip","target_guids":["002340a5-4d00-314d-3030-304a464a5448"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP053419","version":"HPD5.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JFJTH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-304a464a5448"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059278.exe","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VO007680JWCNK and VO015300JWCNL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3330-304a57434e4c","562340a5-304f-3730-3638-304a57434e4b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058524.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8b303467"],"type_of_change":"0","version":"2.51.4.2"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Agentless Management Service for Microsoft Windows x64","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317","10.0","10.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","H08","H10","U50","I44","H08","U61","U60","A43","A47","I41","U33","I43","I42","U37","U39","U34","U30","U64","A48","U34","U47","U47","U56","A40","A46","U46","U31","U46","H09","U48","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-smartpqi-2.1.26-030.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.26-030"},{"name":"kmod-smartpqi-2.1.26-030.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.26-030"}],"installation_dependency":{},"name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 9 (64-bit)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U65","U65","U38","U38","A43","A42","A42","A43","U54","A56","U40","U41","U32","A42","A43","U58","A55","O43","U50","I44","U58","U54","U61","U60","U63","A47","U54","U33","I43","I42","U37","U40","U36","I45","U34","U30","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U31","U46","U62","U63","U58","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-edf6dcd906-HPD9-8.1.x86_64.rpm","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-334f-3230-304a4646434c","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8a7ecf7465-HPD4-5.1.x86_64.rpm","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-5600-314f-3630-304a45414246","002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245"],"supported_operating_systems":[{"os":"Linux","version":["12.0","8.0","15.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058377.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"type_of_change":"1","version":"1.14.201.0"}],"installation_dependency":{},"name":"Intel iavf Driver for Windows Server 2022","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-157180860001"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A42","A55","U56","U54","A56","U65","H10","H08","A55","A42","H08","U54","U61","U58","U63","02020001","03020102","U54","U60","03030201","U59","U65","03020101","A56","U58","H10","H10","H09","U62","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-3db7640485-HPGG-6.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-304757485255","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","562340a5-304b-3030-3234-304757455a42","4d2340a5-304b-3030-3438-304757455a48","562340a5-304b-3030-3438-304757455a43","4d2340a5-304b-3030-3936-304757455a4b","562340a5-304b-3030-3936-304757455a44"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPNSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD2"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPNSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053349.zip","target_guids":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP053349","version":"HPD2.6-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JYDNE and MB004000JYDPB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-7505dfb5ae-HPD8-6.1.x86_64.rpm","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3230-304a45544b43","002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U47_2.00_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.00 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp060124.exe","target_guids":["00000000-0000-0000-0000-000000000227"],"type_of_change":"1","version":"2.00_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["FTP","U47","U47"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058493.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa","20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2023.10.01","vib_list":[{"name":"qlnativefc","version":"5.3.82.0-1OEM.703.0.0.18644231"}]}],"installation_dependency":{},"name":"HPE QLogic Fibre Channel driver component for VMware vSphere 7.0","per_device_install_time_seconds":380,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.3006"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.3006"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP056823.zip","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.6","vib_list":[{"name":"CP056823","version":"1.0.5-7.0.0.15525992"}]}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 7.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","03020102","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_40_1000-MCX653106A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900345","Version":"20.40.1000"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"20_40_1000-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900345"],"type_of_change":"1","version":"20.40.1000"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b15900345"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","A42","U58","A55","U50","U50","A43","A47","U54","U58","A48","U47","U47","U47","U47","A55","A40","A56","A46","U46","U46","U46","U59","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK76H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK76H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK76H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-6628fce235-EPK76H3Q-4.1.x86_64.rpm","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"1","version":"EPK76H3Q"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-505a-4a4c-3654-3448bda98199","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3154-3648f52fd02c"],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","12.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U64_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.00 (02/01/2024)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U64_2.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.00 (02/01/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u64-2.00_2024_02_01-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"type_of_change":"1","version":"2.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0"]}],"supported_platforms":false,"supported_products":["U64","FTP"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052316.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59"],"type_of_change":"1","version":"1010.14.0.0"}],"installation_dependency":{},"name":"HPE Smart Array S100i SR Gen10 SW RAID Driver for Windows Server 2022","per_device_install_time_seconds":400,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a256159000e6"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U38","U38","U40","U39","U41","U32","U33","I43","I42","U37","U40","U36","U34","U30","U34","A40","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059333.zip","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4","vib_list":[{"name":"CP059333","version":"4ICSHPK4.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055597.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7654434b","20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2023.09.01","vib_list":[{"name":"lpfc","version":"14.2.567.0-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 7.0","per_device_install_time_seconds":240,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-852266afdf-HPD5-5.1.x86_64.rpm","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA4_FH_4p30_PLDMoMCTP_8001AF35.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"4.30"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_E810_XXVDA4_FH_4p30_PLDMoMCTP_8001AF35.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-159380860005"],"type_of_change":"1","version":"4.30"}],"installation_dependency":{},"name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159380860005"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","U65","H10","H08","A55","A42","U50","H08","U54","U61","U58","U63","A43","A47","U54","U60","A48","U57","U59","U47","U47","A43","A56","A56","U58","H10","U46","H10","U46","H09","U62","U63","U58"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.21"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.21"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.21"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.21"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.21.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.21"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-qlogic-nx2-2.34.0-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"type_of_change":"1","version":"2.34.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0","15.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U40","U41","U32","U30","O43","U40","U33","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058434.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c"],"type_of_change":"1","version":"2024.04.01","vib_list":[{"name":"smartpqi","version":"80.4600.0.115-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 8.0 (Driver Component).","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U65","U65","U38","U38","A43","U62","A42","A42","A43","U54","A56","U40","U41","U32","A42","U58","A55","O43","U50","I44","U58","U54","U61","U60","U63","A43","A47","U54","U33","I43","I42","U37","U40","U36","I45","U34","U30","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U31","U46","U48","U63","U58","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059317.zip","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP059317","version":"HPD6.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB2000JFEML and MB4000JFEMN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304a46454d4e","002340a5-4d00-3242-3030-304a46454d4c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058300.exe","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.09"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.09"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.09"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.09.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.09"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp058192.exe","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"1","version":"5.3.5.50"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"8.37.37.0","description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","03020101","02020001","A40","03020102"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.00 (03/06/2024)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.00 (03/06/2024)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_2.00_03_06_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.00 (03/06/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059624.exe","target_guids":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"type_of_change":"1","version":"2.00_03-06-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U46","FTP","U46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060555.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"type_of_change":"0","version":"1.0.0.0"}],"installation_dependency":{},"name":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-11f8-400011f84000","a6b1a447-382a-5a4f-11f8-405211f84052"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":true,"supported_products":["A47","A48","I44"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_3006-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.3006"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_3006-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.3006"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp057936.exe","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.0.14"}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Windows x86_64 platform","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","03020102","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-iavf-4.9.1-1.rhel9u0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"1","version":"4.9.1-1"},{"name":"kmod-hp-iavf-4.9.1-1.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"1","version":"4.9.1-1"},{"name":"kmod-hp-iavf-4.9.1-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"1","version":"4.9.1-1"}],"installation_dependency":{},"name":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U40","U41","U32","A42","H08","U58","A55","O43","H10","U56","U50","U58","H08","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U54","U46","U46","H09","U48","U63","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-elx-lpfc-14.2.589.21-1.rhel9u3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"14.2.589.21"}],"installation_dependency":{},"name":"Red Hat Enterprise Linux 9 Server update 3 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-d39e7a7e75-HPG1-11.1.x86_64.rpm","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.3006"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.3006"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP056758.zip","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.2","vib_list":[{"name":"CP056758","version":"1.0.0-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","03020102","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053406.zip","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP053406","version":"HPD3.2-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57554442"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWUEA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57554541","Version":"HPK2"},{"DeviceName":"VO001920KWUEB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57554542","Version":"HPK2"},{"DeviceName":"VO003840KWUEC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57554543","Version":"HPK2"},{"DeviceName":"VO007680KWUED","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57554544","Version":"HPK2"},{"DeviceName":"VO015360KWUEE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304b57554545","Version":"HPK2"},{"DeviceName":"MO000800KWUDR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b57554452","Version":"HPK2"},{"DeviceName":"MO001600KWUDT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57554454","Version":"HPK2"},{"DeviceName":"MO003200KWUDU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57554455","Version":"HPK2"},{"DeviceName":"MO006400KWUDV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57554456","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059334.zip","target_guids":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"type_of_change":"1","version":"HPK2","vib_list":[{"name":"CP059334","version":"HPK2.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi  - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"23.10-1.1.9.1"},{"name":"kmod-mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"23.10-1.1.9.1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"name":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ConnectX-4, ConnectX-5 and ConnectX-6 Driver for Red Hat Enterprise Linux 8 Update 8 (x86_64)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U65","U43","U38","U38","A43","U65","A42","A42","A43","U45","A56","U40","U39","U41","U32","A42","U58","U25","A55","U21","U50","U56","U50","U54","U61","U58","U63","U59","A43","A47","02020001","U54","P89","P89","U37","U36","U34","U30","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U46","U54","U46","U46","A55","U62","U63","U58","U31","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U40_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U40","U40"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-624b75c7e2-HPD6-11.1.x86_64.rpm","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"1","version":"HPD6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFEML and MB4000JFEMN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"smartpqi-kmp-default-2.1.26-030.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.26-030"},{"name":"smartpqi-kmp-default-2.1.26-030.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.26-030"}],"installation_dependency":{},"name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U65","U65","U38","U38","A43","A42","A42","A43","U54","A56","U40","U41","U32","A42","U58","A55","O43","U50","I44","U58","U54","U61","U60","U63","A43","A47","U54","U33","I43","I42","U37","U40","U36","I45","U34","U30","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U31","U46","U62","U63","U58","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG2"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059879.zip","target_guids":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP059879","version":"HPG2.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000GXMTK and MB020000GXMTQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059093.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"23.10.26252.0"}],"installation_dependency":{},"name":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159000d3","a6b1a447-382a-5a4f-15b3-1016159000d4","a6b1a447-382a-5a4f-15b3-101815900246"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","P89","P89","U37","U39","U40","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053417.zip","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPDA","vib_list":[{"name":"CP053417","version":"HPDA.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JEFRB and MM2000JEFRC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.28.41"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059043.zip","target_guids":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"type_of_change":"1","version":"1.37.0","vib_list":[{"name":"CP059043","version":"1.37.0.7-8.0.0.20613240"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"}]}]}]},"name":"Broadcom NX1 Online Firmware Upgrade Utility for VMware","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":true,"supported_products":["U46","A42","A42","U65","U43","A43","U46","A42","A42","U56","U54","U65","A42","U58","U46","U47","U46","A55","U50","H10","U50","U54","U61","U58","U63","U59","A43","A43","U54","U62","U60","U65","U47","U47","U47","A43","A56","A56","A46","H10","A55","U46","H10","U46","U48","U63","U58"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U50_2.00_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.00 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U50_2.00_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000022b"],"type_of_change":"1","version":"2.00_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5"]}],"supported_platforms":false,"supported_products":["U50"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059330.exe","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWTFD and MB012000JWTFC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-12304c1aca-HPG6-2.1.x86_64.rpm","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"ssa-6.30-8.0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"type_of_change":"1","version":"6.30.8.0"}],"installation_dependency":{},"name":"Smart Storage Administrator (SSA) for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","8.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["U27","P95","A43","A43","U54","U40","U41","U12","U13","U32","Carbondale14","U14","U14","U25","Carbondale14","U19","U34","A47","U33","U54","U40","I45","A48","O42","U58","U39","U38","U38","U38","U38","U38","U65","A42","P85","A55","U23","U21","P89","I44","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U31","U31","A42","U13","U24","U14","U18","U18","I43","I42","U37","U18","U57","U20","U20","A40","U62","U63","U17","P86","A42","I40","U65","A46","U22","U50","U54","U63","A43","U39","U40","U36","U58","P92","U34","U47","U47","U58","Carbondale14","U46","U46"]},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059905.exe","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"1","version":"1.1.4"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]}]}]},"name":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","U44","U43","A43","A42","A42","A43","U41","U32","A42","U50","U50","U61","U34","U32","A43","U33","U39","U60","U30","U34","U56","A40","U46","U39","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055359.zip","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"1","version":"HPG5","vib_list":[{"name":"CP055359","version":"HPG5.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-3047574a5051","4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3330-3834-3047574a504b","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3234-3047574a5044"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055174.exe","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JWDFD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3231-3030-304a57444644"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055309.zip","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP055309","version":"HPD2.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi -MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059328.exe","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWJRQ and MB006000JWJRP Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058508.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"23.7.50000.0"}],"installation_dependency":{},"name":"HPE Mellanox OFED Storage Driver for Microsoft Windows Server x64- 2019/2022","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101d1590037d","a6b1a447-382a-5a4f-15b3-101f159003fe"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A42","A42","A43","U54","A42","A55","U50","U50","U54","U63","A43","A47","U54","U58","A48","U47","U47","A55","A56","A56","A46","U46","U46","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059316.zip","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP059316","version":"HPK3.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi  - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-304b57564d56","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3130-3932-304b57564d54"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052984.exe","target_guids":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b8a60fbe9a-HPD5-9.1.x86_64.rpm","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3330-3834-304a57465756"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057766.exe","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057765.zip","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP057765","version":"HPD5.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059020.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"1","version":"228.0.121.0"}],"installation_dependency":{},"name":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16c514e41593","a6b1a447-382a-5a4f-14e4-16c514e41592","a6b1a447-382a-5a4f-14e4-16bd14e41593","a6b1a447-382a-5a4f-14e4-16bd14e41592","a6b1a447-382a-5a4f-14e4-16bd14e41595","a6b1a447-382a-5a4f-14e4-16bd14e41594","a6b1a447-382a-5a4f-14e4-16bd14e41597","a6b1a447-382a-5a4f-14e4-16bd14e41596","a6b1a447-382a-5a4f-14e4-16c514e41595","a6b1a447-382a-5a4f-14e4-16c514e41594","a6b1a447-382a-5a4f-14e4-16c514e41597","a6b1a447-382a-5a4f-14e4-16c514e41596","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e416d8","a6b1a447-382a-5a4f-14e4-16dc14e416d6","a6b1a447-382a-5a4f-14e4-16dc14e416d7","a6b1a447-382a-5a4f-14e4-16dc14e41593","a6b1a447-382a-5a4f-14e4-16dc14e41592","a6b1a447-382a-5a4f-14e4-16c114e41593","a6b1a447-382a-5a4f-14e4-16c114e41592","a6b1a447-382a-5a4f-14e4-16c114e41595","a6b1a447-382a-5a4f-14e4-16c114e41594","a6b1a447-382a-5a4f-14e4-16c114e41597","a6b1a447-382a-5a4f-14e4-16c114e41596","a6b1a447-382a-5a4f-14e4-16dc14e41595","a6b1a447-382a-5a4f-14e4-16dc14e41594","a6b1a447-382a-5a4f-14e4-16dc14e41597","a6b1a447-382a-5a4f-14e4-16dc14e41596","a6b1a447-382a-5a4f-14e4-180814e41599","a6b1a447-382a-5a4f-14e4-180814e41598","a6b1a447-382a-5a4f-14e4-180914e41599","a6b1a447-382a-5a4f-14e4-180914e41598","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180614e41751","a6b1a447-382a-5a4f-14e4-180614e41599","a6b1a447-382a-5a4f-14e4-180614e41598","a6b1a447-382a-5a4f-14e4-180714e41599","a6b1a447-382a-5a4f-14e4-180714e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U65","U43","A43","U62","A42","A42","U56","U54","A56","U65","A42","U58","A55","U50","H10","U50","U54","U61","U58","U63","U59","A43","U54","U65","U40","U60","U64","03030201","U47","U47","U47","A43","A56","A46","H10","A55","U46","H10","U46","U48","U63","U58"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-a47-3.00_2024_01_26-2.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0"]}],"supported_platforms":false,"supported_products":["A47"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021d","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021d","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021f","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021f","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021f","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021f","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809015900220","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021b","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021b","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021b","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021b","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021a","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021a","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021a","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021a","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021d","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021f","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f015900220","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021b","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021a","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002bd","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8090159002bd","Version":"8.65.09"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.65.09_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f0159002bd","Version":"8.65.09"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"ql_hp_ah_mbi_8.65.09_pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80f01590021d","a6b1a447-382a-5a4f-1077-80f01590021f","a6b1a447-382a-5a4f-1077-80f015900220","a6b1a447-382a-5a4f-1077-80f01590021b","a6b1a447-382a-5a4f-1077-80f01590021a","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-80f0159002bd"],"type_of_change":"1","version":"8.65.09"}],"installation_dependency":{},"name":"HPE QLogic FastLinQ Firmware Package for Arrowhead adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","12.0","15.0","7.0","8.0"]}],"supported_platforms":true,"supported_products":["U30","U45","U34","U44","U43","U38","U38","U33","U26","U31","U37","U39","U40","U41","U34","U32","U36","U31","U30"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052749.exe","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWCBC and MB002000GWCBD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"ice-kmp-default-1.12.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"type_of_change":"1","version":"1.12.6-1"},{"name":"ice-kmp-default-1.12.6_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"type_of_change":"1","version":"1.12.6-1"}],"installation_dependency":{},"name":"Intel ice Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U40","U41","U32","A42","H08","U58","A55","O43","H10","U56","U50","U58","H08","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U54","U46","U46","H09","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-cf0b6cabe1-HPD4-3.1.x86_64.rpm","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3631-3030-304a575a4845","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3231-3030-304a575a4842"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-d6020-2.74-15.1.x86_64.rpm","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","12.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["U30","A41","U45","U34","U44","U43","U38","U38","I41","A40","U33","U37","U39","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp051142.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"type_of_change":"1","version":"1.14.201.0"}],"installation_dependency":{},"name":"HPE Intel iavf Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37cd80860001","a6b1a447-382a-5a4f-8086-157180860001"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWUEA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57554541","Version":"HPK2"},{"DeviceName":"VO001920KWUEB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57554542","Version":"HPK2"},{"DeviceName":"VO003840KWUEC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57554543","Version":"HPK2"},{"DeviceName":"VO007680KWUED","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57554544","Version":"HPK2"},{"DeviceName":"VO015360KWUEE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304b57554545","Version":"HPK2"},{"DeviceName":"MO000800KWUDR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b57554452","Version":"HPK2"},{"DeviceName":"MO001600KWUDT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57554454","Version":"HPK2"},{"DeviceName":"MO003200KWUDU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57554455","Version":"HPK2"},{"DeviceName":"MO006400KWUDV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57554456","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-726d5ec795-HPK2-3.1.x86_64.rpm","target_guids":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"type_of_change":"1","version":"HPK2"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"A48_3.00_01_26_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000022f"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A48"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059324.zip","target_guids":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85032G00","vib_list":[{"name":"CP059324","version":"85032G00.6-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ Drives","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055191.exe","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053412.zip","target_guids":["002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG9","vib_list":[{"name":"CP053412","version":"HPG9.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MM2000GEFRA Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-324d-3030-304745465241"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG8"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP054181.zip","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP054181","version":"HPG8.1-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304757544646","4d2340a5-3042-3231-3030-304757544645"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059640.zip","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP059640","version":"HPD8.2-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"supported_operating_systems":[{"os":"VMware","version":["8.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060119.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf4d60f54"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"sut","version":"800.5.0.0.11-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"Integrated Smart Update Tools 5.0.0 for ESXi 8.0","per_device_install_time_seconds":150,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U65","A43","A42","A42","A43","A40","U40","U39","U41","U32","A42","U65","U58","U46","A55","U56","U50","I44","U58","U54","U61","U60","U63","A43","A47","U33","I43","I42","U54","U62","I45","U34","U30","U64","A48","U57","U34","U59","U47","U47","A55","A56","A56","A46","U54","U46","U46","U48","U63","U58","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG4"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG4"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG4"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-492a9952f6-HPG4-5.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-e800e8d3b9-HPD4-10.1.x86_64.rpm","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - MB6000JVYZD and MB4000JVYZC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304a56595a43","002340a5-4d00-3642-3030-304a56595a44"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3030-3936-30505a57534c","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3130-3932-30505a57534e","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3330-3834-30505a575350","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3730-3638-30505a584642","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"562340a5-304f-3531-3336-30505a584555","Version":"HPD3"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"component_location":[],"files":[{"name":"Samsung_PM165X_GPM1653SAMD3.fwpkg","target_guids":["562340a5-304f-3030-3936-30505a57534c","562340a5-304f-3130-3932-30505a57534e","562340a5-304f-3330-3834-30505a575350","562340a5-304f-3730-3638-30505a584642","562340a5-304f-3531-3336-30505a584555"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.2.14.1009","description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.24.3-4948","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Universal Firmware Package for Drives - VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-30505a57534c","562340a5-304f-3130-3932-30505a57534e","562340a5-304f-3330-3834-30505a575350","562340a5-304f-3730-3638-30505a584642","562340a5-304f-3531-3336-30505a584555"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317","10.0.14393.17599","10.0.17600.18999","8.0","15.0","12.0","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059296.exe","target_guids":["562340a5-304b-3130-3932-304b57445548","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3430-304b5744554b"],"type_of_change":"1","version":"HPK4"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) -  MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3030-3430-304b5744554b","4d2340a5-304b-3030-3830-304b5744554c","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3438-304b57445545","562340a5-304b-3030-3936-304b57445546","562340a5-304b-3130-3932-304b57445548"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058585.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"type_of_change":"1","version":"2023.09.20","vib_list":[{"name":"nmst","version":"4.25.0.703-1OEM.703.0.0.18644231"}]}],"installation_dependency":{},"name":"net-mst kernel module driver component for VMware ESXi 7.0 Update 3","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101315900221"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A43","U56","U54","U40","I38","U41","U12","U13","U32","U14","U14","U25","I36","U19","U57","A47","02020001","U54","U54","U61","A48","03030201","A43","U58","U39","U38","U38","U65","A42","P85","A55","U21","P89","U30","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U31","U31","A41","A42","U45","U13","U24","I41","I43","I42","U37","U34","U20","U20","I36","A40","U62","U63","U17","P86","U43","A42","03020101","I40","U65","A46","U50","U22","U50","U63","A43","U39","U36","U58","P92","U34","U47","U47","U47","U47","U58","U46","U46","U46"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-smartpqi-2.1.26-030.rhel8u8.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.26-030"},{"name":"kmod-smartpqi-2.1.26-030.rhel8u7.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.26-030"}],"installation_dependency":{},"name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 8 (64-bit)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U65","U65","U38","U38","A43","A42","A42","A43","U54","A56","U40","U41","U32","A42","A43","U58","A55","O43","U50","I44","U58","U54","U61","U60","U63","A47","U54","U33","I43","I42","U37","U40","U36","I45","U34","U30","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U31","U46","U62","U63","U58","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPNSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD2"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARBPNSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059288.exe","target_guids":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"6.00"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"6.00"},{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-d3000-6.00-2.1.x86_64.rpm","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"type_of_change":"1","version":"6.00"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","12.0","15.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-7f2a26e6d0-HPG1-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWKGR Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-3047574b4752"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.10 (02/22/2024)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.10 (02/22/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059396.exe","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDA"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDA"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDA"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDA"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDA"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTNDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057692.exe","target_guids":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"type_of_change":"1","version":"HPDA"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-54addf5312-HPK3-11.1.x86_64.rpm","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"1","version":"HPK3"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060562.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"0","version":"10.1.18807.8279"}],"installation_dependency":{},"name":"Identifiers for Intel Xeon E-22xx Processor for Microsoft Windows","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["U48","U44","U43"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058995.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"type_of_change":"1","version":"8.72.11.0"}],"installation_dependency":{},"name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-8090159002bf","a6b1a447-382a-5a4f-1077-8090159002be","a6b1a447-382a-5a4f-1077-8090159002c0","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80901590021b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","U30","O43","U40","02020001","U33","03020102","U37","U39","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD2"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059876.zip","target_guids":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP059876","version":"HPD2.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000JXMTH and MB020000JXMTP Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3831-3030-304a584d5448","4d2340a5-3042-3032-3030-304a584d5450"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK5"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK5"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK5"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK5"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK5"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK5"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM173XAHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059788.exe","target_guids":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"type_of_change":"1","version":"HPK5"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43","562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG5"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG5"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG5"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055311.zip","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG5","vib_list":[{"name":"CP055311","version":"HPG5.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp049814.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6b3a6f74"],"type_of_change":"0","version":"6.0.0.0"}],"installation_dependency":{},"name":"HPE Lights-Out Online Configuration Utility for Windows x64 Editions","per_device_install_time_seconds":100,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-0e11-b2040e11b206","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306103c3381","a6b1a447-382a-5a4f-103c-3307103c3381","a6b1a447-382a-5a4f-103c-3308103c3381","a6b1a447-382a-5a4f-103c-3300103c3381","a6b1a447-382a-5a4f-103c-3301103c3381","a6b1a447-382a-5a4f-103c-3302103c3381","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"supported_operating_systems":[{"os":"Windows","version":["6.2","6.2","6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["P95","I30","I31","A43","U40","I38","U41","Carbondale14","U13","Carbondale14","Carbondale14","U14","U14","U25","I36","U19","P78","U34","A47","U33","U24","U64","O42","U39","U38","U38","J10","A42","P85","J03","U32","P75","U23","U21","P89","A45","I44","I40","I32","P83","P77","I37","P89","P89","U15","U15","P99","P73","P73","A26","P88","A55","I39","A55","A56","A56","U48","U26","U31","U31","A41","U45","P94","U13","P70","P71","J02","A28","P72","P75","U24","U14","U51","U30","I41","U18","U18","I43","I42","U37","I31","U18","U20","U20","I36","A40","I15","U17","P86","U44","U43","J06","I40","P75","U50","U22","U50","U61","J05","J04","P80","P64","P74","U36","U60","P92","U34","P75","U47","U47","U47","U47","A46","U46","U46","P79","U46","W04"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"A40_3.00_01_26_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.5","6.7","7.0","8.0"]}],"supported_platforms":false,"supported_products":["A40"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-bfc4af697b-HPG6-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWFWK and MB002000GWFWL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPK2"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPK2"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8e8ddc5265-HPK2-4.1.x86_64.rpm","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPK2"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3054-3630-3430-304b57484145","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3130-3630-304b57484143"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK5"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK5"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK5"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-1a541ed00d-GPK5-2.1.x86_64.rpm","target_guids":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"type_of_change":"1","version":"GPK5"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","12.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp054533.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb135dd88"],"type_of_change":"0","version":"1.0.0.1"}],"installation_dependency":{},"name":"HPE Emulex Fibre Channel Smart SAN Enablement Kit for Host Bus Adapters for Microsoft Windows Server 2022 (x86_64) ","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","SPP","A42","A43","U40","U39","U41","U32","A42","U50","A42","A43","A47","U33","U37","U34","U30","A48","U34","U47","U47","A40","A46","U46","U48","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK76H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK76H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK76H3Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK76H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059305.exe","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"1","version":"EPK76H3Q"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3654-3448bda98199","4d2340a5-505a-4a4c-3354-3248fdc50136"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.14393.17599","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U33_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.0","6.5","6.7","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U33"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"22_39_1002-MCX623106AS-CDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30042","Version":"22.39.1002"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"22_39_1002-MCX623106AS-CDA_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"type_of_change":"1","version":"22.39.1002"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","A42","U58","H10","A55","U50","H10","U50","U54","U61","U57","U63","A43","A47","U54","U58","A48","U47","U47","U47","U47","U56","A40","A56","A46","U46","A55","U46","H10","U46","U62","U59","U58"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.2.589.19"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.2.589.19"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.2.589.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.2.589.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.2.589.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.2.589.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.2.589.19"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.2.589.19"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-fc-emulex-2023.10.01-3.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2023.10.01"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG2"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SLONGSPKETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059880.exe","target_guids":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"type_of_change":"1","version":"HPG2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB018000GXMTK and MB020000GXMTQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059638.exe","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPDB"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056785.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"type_of_change":"1","version":"12.18.16.0"}],"installation_dependency":{},"name":"Intel i350 Driver for Windows Server 2019","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A42","A55","U56","U54","A56","U65","H10","H08","A55","H08","U54","U61","U58","U63","02020001","03020102","U54","U60","03030201","U59","U65","03020101","A56","U58","H10","H10","H09","U62","U63","U58"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"23.10-1.1.9.1"},{"name":"kmod-mlnx-ofa_kernel-23.10-OFED.23.10.1.1.9.1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"23.10-1.1.9.1"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"name":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ConnectX-4, ConnectX-5 and ConnectX-6 Driver for Red Hat Enterprise Linux 9 Update 2 (x86_64)","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U65","U43","U38","U38","A43","U65","A42","A42","A43","U45","A56","U40","U39","U41","U32","A42","U58","U25","A55","U21","U50","U56","U50","U54","U61","U58","U63","U59","A43","A47","02020001","U54","P89","P89","U37","U36","U34","U30","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U46","U54","U46","U46","A55","U62","U63","U58","U31","U31"]},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp059617.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.603"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-spsgen10plus-04.04.04.603-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000101"],"type_of_change":"0","version":"04.04.04.603"}],"installation_dependency":{},"name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Plus Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U47","U47","U56","H10","U50","U46","H10","U46","I44","H10"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055342.zip","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG","vib_list":[{"name":"CP055342","version":"HPGG.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-3052-3130-3932-304757464d43","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3438-304757464c56","4d2340a5-3052-3030-3234-304757464c55"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-befd42bd64-HPG3-2.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP056439.zip","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP056439","version":"HPG3.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.3006"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057774.zip","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.7","vib_list":[{"name":"CP057774","version":"1.0.5-7.0.0.15525992"}]}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox Ethernet only adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U38","U38","A43","A42","A42","A43","U40","U39","U41","U32","A42","U25","U50","U19","U22","U50","U61","A43","A47","P89","P89","U37","U36","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U39"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD3"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD3"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD3"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD3"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD3"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD3"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD3"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD3"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD3"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD3"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD3"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-42aff4675b-HPD3-4.1.x86_64.rpm","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3531-3330-305058444256","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059944.zip","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74","vib_list":[{"name":"CP059944","version":"2.74.1-7.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":["U30","A41","U46","U45","U34","U44","U43","U38","U38","I41","A40","U33","U37","U39","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG8"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b78255e146-HPG8-3.1.x86_64.rpm","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWTFE and MB014000GWTFF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304757544646","4d2340a5-3042-3231-3030-304757544645"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059662.exe","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U38","U38","U38","U38","U38"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052318.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec14b13c05"],"type_of_change":"1","version":"106.124.100.1005"}],"installation_dependency":{},"name":"HPE Smart Storage SR100i Gen10 Plus SW RAID Driver for Windows Server 2016 and Windows Server 2019","per_device_install_time_seconds":400,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A43","A43","U47","U47","U50","A42","A42","A46","A43","U46","U46","I44","A42"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055331.zip","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP055331","version":"HPD7.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB8000JFECQ Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3842-3030-304a46454351"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp050934.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbf0a9496","20a6e8e4-bf33-4c71-a6bf-d9ecb46a2f45"],"type_of_change":"1","version":"2022.09.01","vib_list":[{"name":"fc-enablement","version":"700.3.9.0.4-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE Fiber Channel and Storage Enablement Bundle Smart Component for ESXi 7.0","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["U54","A41","U17","U44","U43","U38","U38","A43","A42","A42","A43","U45","A56","U40","U41","U32","A42","U58","A55","U47","U50","U56","U50","I44","I39","U58","U54","U61","U60","U63","A43","A47","I41","I37","U54","U33","P89","P89","U37","U64","U62","I45","U34","U30","A48","U57","U34","U59","U47","I36","I43","A40","A56","A46","I42","U46","U31","U46","A55","U48","U63","U58","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK7"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK7"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK7"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059363.zip","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK7","vib_list":[{"name":"CP059363","version":"GPK7.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for VMware ESXi - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG2"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG2"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG2"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG2"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059886.exe","target_guids":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"type_of_change":"1","version":"HPG2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U56_2.00_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.00 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U56_2.00_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000239"],"type_of_change":"1","version":"2.00_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE DL110 Gen10 Plus Telco (U56) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0"]}],"supported_platforms":false,"supported_products":["U56","FTP"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057482.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba","20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd"],"type_of_change":"1","version":"2023.12.01","vib_list":[{"name":"lsi-mr3","version":"7.726.02.00-1OEM.700.1.0.15843807"}]}],"installation_dependency":{},"name":"HPE MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p Gen10P and Gen11 controller (64-bit) Driver for vSphere 7.0","per_device_install_time_seconds":120,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U54","U65","U32","A42","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_CQDA2_OCP_4p30_NCSIwPLDMoMCTP_8001AF24.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"4.30"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_E810_CQDA2_OCP_4p30_NCSIwPLDMoMCTP_8001AF24.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-159280860006"],"type_of_change":"1","version":"4.30"}],"installation_dependency":{},"name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159280860006"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","U65","H10","H08","A55","A42","U50","H08","U54","U61","U58","U63","A43","A47","U54","U60","A48","U57","U59","U47","U47","A43","A56","A56","U58","H10","U46","H10","U46","U62","U63","U58"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u39-3.10_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U39","U39"]},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-powerpic-gen10-1.1.4-2.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"1","version":"1.1.4"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]}]}]},"name":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","12.0","15.0","9.0"]}],"supported_platforms":true,"supported_products":["A41","U44","U43","A43","A42","A42","A43","U41","U32","A42","U50","U50","U61","U34","U32","A43","U33","U39","U60","U30","U34","U56","A40","U46","U39","U46","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058579.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdf9a8250"],"type_of_change":"1","version":"6.30.8.0"}],"installation_dependency":{},"name":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U27","P95","A43","A43","U54","U40","U41","U12","U13","U32","Carbondale14","U14","U14","U25","Carbondale14","U19","A47","U33","U54","I45","A48","O42","U58","U39","U38","U38","U38","U38","U38","U65","A42","P85","A55","U23","U21","P89","I44","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U31","U31","A42","U14","U13","U24","U40","U18","U18","I43","I42","U37","U18","U34","U57","U20","U20","A40","U62","U63","U17","P86","A42","I40","U65","A46","U22","U50","U54","U63","A43","U39","U40","U36","U58","P92","U34","U47","U47","U58","Carbondale14","U46","U46"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.28.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.28.41"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-bcm-2.36.0-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"1","version":"2.36.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.42","description":"HPE Broadcom Firmware version 20.26.42 or greater is required and should be already active"}]}]}]},"name":"HPE Broadcom NX1 Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen10 server series Only.","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0","15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","U36","02020001","U33","03020102","U37","U39","U40","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059442.zip","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG7","vib_list":[{"name":"CP059442","version":"HPG7.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-f0c91d2fe3-HPD4-6.1.x86_64.rpm","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWFUV and EG001200JWFVA Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3230-304a57465641","452340a5-3047-3030-3630-304a57465556"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059947.zip","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0130","vib_list":[{"name":"CP059947","version":"0130.1-7.0.0.15525992"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","per_device_install_time_seconds":1200,"reboot_required":"no","support_url":"","supported_devices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U40","U41","U32","A42","U46","U50","U61","U60","A43","I41","U33","U37","U34","U30","U34","U47","U47","A40","U46","U31","U46","U39","U31"]},{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM1 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_UBM1_1.46_B.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901501000000","Version":"1.46"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_UBM1_1.46_B.fwpkg","target_guids":["9675b54e-1c96-44c3-a7a1-901501000000"],"type_of_change":"1","version":"1.46"}],"installation_dependency":{},"name":"Firmware Package - UBM1 Backplane PIC PLDM Firmware","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","10.0.14393.17599","8.0","15.0","12.0","10.0.20317","7.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U47","U47","A46","A43","I44","A42"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-hp-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"1","version":"5.19.6-1"},{"name":"kmod-hp-ixgbe-5.19.6-1.rhel9u0.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"1","version":"5.19.6-1"},{"name":"kmod-hp-ixgbe-5.19.6-1.rhel9u1.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"1","version":"5.19.6-1"}],"installation_dependency":{},"name":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-2cfaac41db-HPDB-12.1.x86_64.rpm","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEQNL and MB6000JEQNN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM3 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_UBM3_1.24_E.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901503000000","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_UBM3_1.24_E.fwpkg","target_guids":["9675b54e-1c96-44c3-a7a1-901503000000"],"type_of_change":"1","version":"1.24"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4597","description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4650","description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"52.22.3-4650","description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.32","description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.14.062","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Firmware Package - UBM3 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 servers usage","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","8.0","15.0","10.0.20317","8.0","9.0","10.0.14393.17599","7.0","12.0"]}],"supported_platforms":false,"supported_products":["A43","A42","A42","A43","U54","A42","U46","A55","U50","U54","U61","U63","A43","U54","I45","U60","U59","A55","A56","A56","U46","U46","U48","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055302.zip","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP055302","version":"HPD4.5-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB004000JWFVK and MB006000JWFVL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058387.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15","20a6e8e4-bf33-4c71-a6bf-d9ece43a8459"],"type_of_change":"1","version":"2023.10.00","vib_list":[{"name":"icen","version":"1.12.5.0-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"Intel icen Driver for VMware vSphere 8.0","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U40","U41","U32","A42","H08","U58","A55","O43","H10","U56","U50","U58","H08","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U54","U46","U46","H09","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055260.zip","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP055260","version":"HPD4.4-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWFVC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3130-3830-304a57465643"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020907.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.09.07"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020907.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.09.07"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020205.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.02.05"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020205.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.02.05"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020205.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.02.05"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020205.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.02.05"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020907.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.09.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020907.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.09.07"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058498.exe","target_guids":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2023.10.01"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.0.1-3","description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active"}]}]}]},"name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2019/2022 (x86_64)","per_device_install_time_seconds":250,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.2.589.19"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.2.589.19"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.2.589.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.2.589.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.2.589.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14258921.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.2.589.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.2.589.19"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14258919.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.2.589.19"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058598.zip","target_guids":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2023.10.01","vib_list":[{"name":"CP058598","version":"2023.10.01.5-7.0.0.15843807"}]}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  8.0","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U46","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053384.zip","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP053384","version":"HPD4.1-8.0.0.19956994"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JWFVN and MB004000JWFVP Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055257.zip","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP055257","version":"HPD3.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - EG000300JWFVB Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3047-3030-3330-304a57465642"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD8"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD8"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8d68452816-HPD8-3.1.x86_64.rpm","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3330-304a5748504c","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3930-304a57485050"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.00 (02/01/2024)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.00 (02/01/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059796.exe","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U48"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056773.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"type_of_change":"1","version":"13.0.16.0"}],"installation_dependency":{},"name":"HPE Intel E1R Driver for Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR216i-a_Gen10P_52.26.3-5379_A.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.26.3-5379"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_MR216i-a_Gen10P_52.26.3-5379_A.fwpkg","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032c"],"type_of_change":"1","version":"52.26.3-5379"}],"installation_dependency":{},"name":"Firmware Package - HPE MR216i-a Gen10 Plus Tri Mode Controller","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"VMware","version":["7.0","10.0.17600.18999","10.0.14393.17599","8.0","15.0","12.0","10.0.20317","7.0","9.0","8.0"]}],"supported_platforms":false,"supported_products":["U46","A43","A43","A42","A42","U46","U46","U61","U60"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055307.zip","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP055307","version":"HPD6.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB010000JWAYK and MB008000JWAYH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055405.zip","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1","vib_list":[{"name":"CP055405","version":"HPD1.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052317.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec14b13c05"],"type_of_change":"1","version":"1010.124.100.1005"}],"installation_dependency":{},"name":"HPE Smart Storage SR100i Gen10 Plus SW RAID Driver for Windows Server 2022","per_device_install_time_seconds":400,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A43","A43","U47","U47","U50","A42","A42","A46","A43","U46","U46","I44","A42"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPDA.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055195.exe","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPDA"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JWXKH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3631-3030-304a57584b48"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP058362.zip","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP058362","version":"HPG8.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059684.exe","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U45"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-8e1e8083c5-HPG3-2.1.x86_64.rpm","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0","7.0","12.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055136.exe","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3430-3030-3047574b4756"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTEDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDC"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTEDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDC"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057698.zip","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPDC","vib_list":[{"name":"CP057698","version":"HPDC.1-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - EH000600JWCPF and EH000900JWCPH Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp057560.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.913"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-microservergen10plussps-05.01.04.913-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.913"}],"installation_dependency":{},"name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus","per_device_install_time_seconds":0,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0"]}],"supported_platforms":true,"supported_products":["U48","FTP"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058578.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9f015b42"],"type_of_change":"1","version":"6.30.8.0"}],"installation_dependency":{},"name":"Smart Storage Administrator (SSA) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U27","P95","A43","A43","U54","U40","U41","U12","U13","U32","Carbondale14","U14","U14","U25","Carbondale14","U19","A47","U33","U54","I45","A48","O42","U58","U39","U38","U38","U38","U38","U38","U65","A42","P85","A55","U23","U21","O43","P89","I44","I40","I37","P89","P89","U15","U15","P99","U30","U59","I39","A55","A56","A56","U48","U31","U31","A42","U14","U13","U24","U40","U18","U18","I43","I42","U37","U18","U34","U57","U20","U20","A40","U62","U63","U17","P86","A42","I40","U65","A46","U50","U22","U50","U54","U63","A43","U39","U40","U36","U58","P92","U34","U47","U47","U58","Carbondale14","U46","U46"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052943.exe","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a574b474e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR216i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.26.3.5379"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP060397.zip","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032c"],"type_of_change":"2","version":"52.26.3.5379","vib_list":[{"name":"CP060397","version":"52.26.3.5379.8-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Controller Firmware Flash for ESXi7.0 and 8.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"VMware","version":["8.0","7.0"]}],"supported_platforms":false,"supported_products":["U30","A43","A43","A42","A42","U46","SPP","U46","U61","U32","U60"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v3.00 (01/26/2024)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v3.00 (01/26/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"A42_3.00_01_26_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0","8.0"]}],"supported_platforms":false,"supported_products":["A42","A42","A42"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK7"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK7"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK7"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK7"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK7"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-6fc985bd3b-GPK7-2.1.x86_64.rpm","target_guids":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"type_of_change":"1","version":"GPK7"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"supported_operating_systems":[{"os":"Linux","version":["8.0","15.0","12.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7725Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7725Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7725Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7725Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7725Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7725Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7725Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7725Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7725Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK7725Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7725Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059791.exe","target_guids":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"type_of_change":"1","version":"MPK7725Q"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-0 Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055208.exe","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055341.zip","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP055341","version":"HPD3.5-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-304f-3830-304a45465046","002340a5-4d00-314f-3630-304a45465043","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-304f-3230-304a45464e56","002340a5-4500-304f-3430-304a45465045","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3830-304a45465042"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059331.zip","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP059331","version":"HPD8.4-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3330-304a57535356","562340a5-304b-3730-3638-304a57535355","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3030-3936-304a57535351"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059282.exe","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3330-304a57535356","562340a5-304b-3730-3638-304a57535355","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3030-3936-304a57535351"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059681.exe","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U37"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-a886842a99-HPD2-6.1.x86_64.rpm","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304a574b474e"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for DL20 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SC_DL20GEN10Plus_ME_06.00.03.604.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.604"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"component_location":[],"files":[{"name":"SC_DL20GEN10Plus_ME_06.00.03.604.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"0","version":"06.00.03.604"}],"installation_dependency":{},"name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus Servers","per_device_install_time_seconds":600,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","7.0"]}],"supported_platforms":true,"supported_products":["FTP","U60"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_3006-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.3006"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP057775.zip","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP057775","version":"1.0.0-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox Ethernet only adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U38","U38","A43","A42","A42","A43","U40","U39","U41","U32","A42","U25","U50","U19","U22","U50","U61","A43","A47","P89","P89","U37","U36","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U39"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-kernel-mft-mlnx-4.26.1-1.rhel9u3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"0","version":"4.26.1-3"},{"name":"mft-4.26.1-3.rhel9u3.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"0","version":"4.26.1-3"}],"installation_dependency":{},"name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 3 (x86_64)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U43","U38","U38","A43","A42","A42","A43","U45","U40","U39","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","U37","U36","U34","U30","A48","U34","03030201","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U47_2.00_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.00 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u47-2.00_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000227"],"type_of_change":"1","version":"2.00_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U47","U47","FTP"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U38_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0"]}],"supported_platforms":false,"supported_products":["U38","U38","U38","U38","U38"]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.5"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.5"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3437.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_FVL4HP.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058406.exe","target_guids":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8"],"type_of_change":"1","version":"5.3.6.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.16.202.0","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.16.202.0","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"For Gen11 server iLO version 1.10 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"name":"HPE Intel Online Firmware Upgrade Utility for Windows Server x64 Editions for HPE ProLiant Gen9 and Gen10 server series Only.","per_device_install_time_seconds":1800,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1581159000f8"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"},{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055169.exe","target_guids":["4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642","4d2340a5-304b-3030-3234-304757434555"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3130-3932-304757434642","4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058340.exe","target_guids":["4d2340a5-3042-3431-3030-304a58554343"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JXUCC Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a58554343"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"libbnxt_re-228.0.133.0-sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"1","version":"228.0.133.0"}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP5","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_3.00_01_26_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v3.00 (01/26/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-a48-3.00_2024_01_26-2.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-00000000022f"],"type_of_change":"1","version":"3.00_01-26-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A48"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055095.exe","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JEHMD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3830-304a45484d44"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.28.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.28.41"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-nic-bcm-open-2.36.0-1.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"type_of_change":"1","version":"2.36.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. "},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"20.26.44","description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.26.44 or greater is required and should be already active"}]}]}]},"name":"Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"supported_operating_systems":[{"os":"Linux","version":["8.0","9.0","15.0"]}],"supported_platforms":true,"supported_products":["U46","A42","A42","U65","U43","A43","U46","A42","A42","U56","U54","U65","A42","U58","U47","U46","A55","U50","H10","U50","U54","U61","U58","U63","U59","A43","A43","U54","U62","U60","U65","U47","U47","U47","A43","A56","A56","A46","H10","A55","U46","H10","U46","U48","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059322.zip","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP059322","version":"HPD4.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-5600-314f-3630-304a45414246","002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD8"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD8"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055198.exe","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["452340a5-3048-3030-3330-304a5748504c","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3930-304a57485050"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"hp-igb-kmp-default-6.14.16_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"1","version":"6.14.16-1"},{"name":"hp-igb-kmp-default-6.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"1","version":"6.14.16-1"}],"installation_dependency":{},"name":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","U65","U62","A42","A55","A56","A43","U54","U40","U41","U32","A42","U58","A55","O43","U56","U50","U58","U54","U61","U60","U63","U59","A43","A47","02020001","U33","03020102","U54","U36","U65","U34","U30","U64","A48","U57","U34","03030201","U47","U47","U47","03020101","A40","A56","A46","U58","U46","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG3"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG3"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG3"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055419.zip","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP055419","version":"HPG3.5-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ  and VK007680GXCGR Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3730-3638-304758434752","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"hp-ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"1","version":"5.19.6-1"},{"name":"hp-ixgbe-kmp-default-5.19.6_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"1","version":"5.19.6-1"}],"installation_dependency":{},"name":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"supported_operating_systems":[{"os":"Linux","version":["15.0"]}],"supported_platforms":true,"supported_products":["A41","U45","U44","U43","U38","U38","J10","03020101","U40","U41","U32","O43","02020001","U33","03020102","U37","U36","U34","U30","U34","A40","U31","U26","U39","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055140.exe","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-3047574b4752"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-cea219e4b1-HPK3-7.1.x86_64.rpm","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Linux (x64) - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055135.exe","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JWFVN and MB004000JWFVP Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055166.exe","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB8000JFECQ Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3842-3030-304a46454351"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052952.exe","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFDSL and MB4000JFDSN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059035.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"type_of_change":"1","version":"1.0.0.50"}],"installation_dependency":{},"name":"AMD PSHED Plug-in service for Microsoft Windows Server 2022","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":true,"supported_products":["A41","A48","A43","A40","A55","A43","A55","A42","A56","A46","A43","A56","A47","A42","A42"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055154.exe","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41595","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41595","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41594","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41594","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41597","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41596","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41593","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41592","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Version":"228.1.111.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm228.1.111.0.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Version":"228.1.111.0"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"bcm228.1.111.0.pup.fwpkg","target_guids":["a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41592"],"type_of_change":"1","version":"228.1.111.0"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"226.1.107.0","description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active"}]}]}]},"name":"Broadcom Firmware Package for BCM5741x adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","12.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","U43","A43","A42","A42","U56","U54","U65","A42","U58","U46","A55","U50","H10","U50","U54","U61","U58","U63","U59","A43","U54","U62","U60","U65","U47","U47","U47","A43","A56","A56","A46","H10","A55","U46","H10","U46","U48","U63","U58"]},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_3006-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.3006"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp057772.exe","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.0.20"}],"installation_dependency":{},"name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox Ethernet only adapters","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"supported_operating_systems":[{"os":"Windows","version":["6.2","6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U45","U38","U38","A43","A42","A42","A43","U40","U39","U41","U32","A42","U25","U50","U19","U22","U50","U61","A43","A47","P89","P89","U37","U36","U34","U30","A48","U34","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U39"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059034.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"type_of_change":"1","version":"1.0.0.50"}],"installation_dependency":{},"name":"AMD PSHED Plug-in service for Microsoft Windows Server 2019","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":true,"supported_products":["A41","A48","A43","A40","A55","A43","A55","A42","A56","A46","A43","A56","A47","A42","A42"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.10 (02/22/2024)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.10 (02/22/2024)"}]},"Type":"ComboFirmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U31_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055592.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"14.2.537.0"}],"installation_dependency":{},"name":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055201.exe","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3052-3030-3936-30475842474b","4d2340a5-3052-3030-3438-304758424748","562340a5-3052-3030-3234-30475842424c","4d2340a5-304b-3330-3834-304758415754","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3030-3438-304758415746","562340a5-304b-3730-3638-304758415751","562340a5-304b-3330-3834-304758415750","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3234-304758415745","562340a5-304b-3130-3932-30475841574e"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_3.10_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.10 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"U41_3.10_02_22_2024.fwpkg","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"3.10_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers ","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"VMware","version":["6.7","6.5","6.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U41"]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_3.00_02_01_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.00 (02/01/2024)"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"component_location":[],"files":[{"name":"cp059862.exe","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"3.00_02-01-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":["U44"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056238.exe","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-1e51a57347-HPD8-8.1.x86_64.rpm","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3330-304a57535356","562340a5-304b-3730-3638-304a57535355","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3030-3936-304a57535351"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058501.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.9.21"}],"installation_dependency":{},"name":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2022","per_device_install_time_seconds":180,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["A41","U38","U38","A42","A43","U40","U41","U32","A42","U30","U50","A47","U37","U36","U34","U30","A48","U34","U47","U47","A40","A46","U46","U46","U31"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Eth 10/25Gb 2p Sec Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"26_38_1002-S2A69-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101f159003fe","Version":"26.38.1002"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"26_38_1002-S2A69-63001_Ax_header.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101f159003fe"],"type_of_change":"1","version":"26.38.1002"}],"installation_dependency":{},"name":"Mellanox Firmware Package(FWPKG) for HPE NV60025M Ethernet 10/25Gb 2-port Secure Network Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f159003fe"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["U59","A56","U63","A43","A55","A56","A42","U58","U50","U54","U46","U54","A55","U46","U57","U58"]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_40_1000-MCX653106A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30074","Version":"20.40.1000"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"20_40_1000-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"type_of_change":"1","version":"20.40.1000"}],"installation_dependency":{},"name":"Mellanox Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter : HPE part numbers P23666-B21 and P23666-H21","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"supported_operating_systems":[{"os":"Windows","version":["6.3","10.0.14393.17599","10.0.17600.18999","10.0.20317","6.0","7.0","8.0","9.0","11.0","12.0","15.0","7.0","8.0","6.5","6.7"]}],"supported_platforms":false,"supported_products":["A41","A43","A42","A42","A43","U54","A56","A42","U58","A55","U50","U50","U54","U63","A43","A47","U54","U58","A48","U47","U47","U47","U47","A55","A40","A56","A46","U46","U46","U46","U59","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055692.exe","target_guids":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"type_of_change":"1","version":"HPG1"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057493.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf81a7df0"],"type_of_change":"1","version":"8.6.18.0"}],"installation_dependency":{},"name":"HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for Gen10P and Gen11 Controllers)","per_device_install_time_seconds":600,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":true,"supported_products":["A43","A42","A42","U54","U65","U32","A55","U54","U61","U58","U63","A43","U54","U60","U30","U59","U65","A55","A56","A56","U46","U46","U63","U58"]},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp057642.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.002"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-spsgen10-04.01.05.002-2.1.x86_64.rpm","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"0","version":"04.01.05.002"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"0.1.4.0","description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer"}]}]}]},"name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"supported_platforms":true,"supported_products":["U30","U45","U34","U37","U38","U38","I41","H08","U33","I43","I42","U39","U40","U39","U41","U31","U32","H08","U31","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp060554.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"type_of_change":"0","version":"1.0.0.0"}],"installation_dependency":{},"name":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2016 and Server 2019","per_device_install_time_seconds":60,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-11f8-400011f84000","a6b1a447-382a-5a4f-11f8-405211f84052"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.14393.17599"]}],"supported_platforms":true,"supported_products":["A47","A48","I44"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-10385ef3e6-HPD2-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-cc819d4bff-HPG5-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"1","version":"HPG5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWAYN and MB008000GWAYL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG8"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp054892.exe","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWTFE and MB014000GWTFF Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3431-3030-304757544646","4d2340a5-3042-3231-3030-304757544645"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-b9340d29be-HPD6-13.1.x86_64.rpm","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"supported_operating_systems":[{"os":"Linux","version":["12.0","15.0","8.0","9.0","7.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055323.zip","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP055323","version":"HPG4.3-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEBTP Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-3642-3030-304745425450"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG3"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG3"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG3"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp053104.exe","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG3"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR  Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3730-3638-304758434752","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052934.exe","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JFHMH Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4500-3147-3830-304a46484d48"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059018.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"type_of_change":"1","version":"2024.03.00","vib_list":[{"name":"bnxtroce","version":"228.0.116.0-1OEM.800.1.0.20613240"},{"name":"bnxtnet","version":"228.0.116.0-1OEM.800.1.0.20613240"}]}],"installation_dependency":{},"name":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 8.0","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"supported_operating_systems":[{"os":"VMware","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","U65","U62","A42","A42","A56","A43","U54","O43","U40","U41","U32","A42","U30","U58","A55","U50","U40","U50","U58","U54","U61","U60","U63","U59","A43","02020001","U54","U33","03020102","U37","U46","U39","U36","U65","U34","U30","U64","U56","U34","03030201","U47","U47","U47","U47","03020101","A40","A56","A46","U58","U65","A55","U46","U39","U46","U48","U63","U26","U31","U31"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058381.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"type_of_change":"1","version":"1.18.367.0"}],"installation_dependency":{},"name":"HPE Intel i40ea Driver for Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP053398.zip","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP053398","version":"HPD2.2-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3830-3030-304a57525444"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U56_2.00_02_22_2024.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.00 (02/22/2024)"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-system-u56-2.00_2024_02_22-1.1.x86_64.rpm","target_guids":["00000000-0000-0000-0000-000000000239"],"type_of_change":"1","version":"2.00_02-22-2024"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"name":"Online ROM Flash Component for Linux - HPE DL110 Gen10 Plus Telco (U56) Servers","per_device_install_time_seconds":300,"reboot_required":"yes","support_url":"","supported_devices":[],"supported_operating_systems":[{"os":"Linux","version":["15.0","8.0","9.0"]}],"supported_platforms":false,"supported_products":["U56","FTP"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp058379.exe","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"type_of_change":"1","version":"4.1.252.0"}],"installation_dependency":{},"name":"HPE Intel ixs Driver for Windows Server 2022","per_device_install_time_seconds":360,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1"],"supported_operating_systems":[{"os":"Windows","version":["10.0.20317"]}],"supported_platforms":false,"supported_products":["U30","A41","U34","U44","U43","U38","U38","02020001","A40","U33","03020102","03020101","U37","U40","U41","U31","U32","U31","U34"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"kmod-kernel-mft-mlnx-4.26.1-1.rhel8u9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"0","version":"4.26.1-3"},{"name":"mft-4.26.1-3.rhel8u9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"0","version":"4.26.1-3"}],"installation_dependency":{},"name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 8 Update 9 (x86_64)","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"Linux","version":["8.0"]}],"supported_platforms":false,"supported_products":["A41","U17","U43","U38","U38","A43","A42","A42","A43","U45","U40","U39","U41","U32","A42","U50","U50","U61","A43","A47","02020001","03020101","U37","U36","U34","U30","A48","U34","03030201","U47","U47","U47","U47","U56","A40","A46","U46","U46","U46","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP055686.zip","target_guids":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP055686","version":"HPG1.1-8.0.0.20143090"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives.","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWUEA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57554541","Version":"HPK2"},{"DeviceName":"VO001920KWUEB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57554542","Version":"HPK2"},{"DeviceName":"VO003840KWUEC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57554543","Version":"HPK2"},{"DeviceName":"VO007680KWUED","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57554544","Version":"HPK2"},{"DeviceName":"VO015360KWUEE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304b57554545","Version":"HPK2"},{"DeviceName":"MO000800KWUDR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b57554452","Version":"HPK2"},{"DeviceName":"MO001600KWUDT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57554454","Version":"HPK2"},{"DeviceName":"MO003200KWUDU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57554455","Version":"HPK2"},{"DeviceName":"MO006400KWUDV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM5ALLHPK2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57554456","Version":"HPK2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059290.exe","target_guids":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"type_of_change":"1","version":"HPK2"}],"installation_dependency":{},"name":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD3"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD3"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD3"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD3"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"CP059882.zip","target_guids":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP059882","version":"HPD3.3-8.0.0.20613240"}]}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"supported_operating_systems":[{"os":"VMware","version":["7.0","8.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp059273.exe","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPDA"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JEFRB and MM2000JEFRC Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","10.0.14393.17599"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_CQDA2_4p30_PLDMoMCTP_8001AF29.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"4.30"}]},"Type":"Firmware","UpdatableBy":["Bmc"],"component_location":[],"files":[{"name":"HPE_E810_CQDA2_4p30_PLDMoMCTP_8001AF29.fwpkg","target_guids":["a6b1a447-382a-5a4f-8086-159280860002"],"type_of_change":"1","version":"4.30"}],"installation_dependency":{},"name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-8086-159280860002"],"supported_operating_systems":[{"os":"Windows","version":["10.0.17600.18999","10.0.20317","8.0","9.0","15.0","7.0","8.0"]}],"supported_platforms":false,"supported_products":["U65","A42","A55","U56","U54","U65","H10","H08","A55","A42","U50","H08","U54","U61","U58","U63","A43","A47","U54","U60","A48","U57","U59","U47","U47","A43","A56","A56","U58","H10","U46","H10","U46","U62","U63","U58"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp057760.exe","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"amsd-3.5.0-1803.58.rhel9.x86_64.rpm","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"0","version":"3.5.0"}],"installation_dependency":{},"name":"Agentless Management Service (iLO 5, iLO 6) for Red Hat Enterprise Linux 9 Server","per_device_install_time_seconds":0,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"supported_operating_systems":[{"os":"Linux","version":["9.0"]}],"supported_platforms":false,"supported_products":["A41","U45","U44","U43","U38","U38","A43","A42","A42","A43","U54","A56","U40","U41","U32","A42","U65","U58","A55","U50","A45","I44","U58","U54","U61","U60","U63","A43","A47","I41","U33","I43","I42","U37","U24","I45","U34","U30","U64","A48","U57","U34","U59","U47","U47","A55","A40","A56","A46","U46","U46","U46","U65","U62","U63","U58","U54"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"firmware-hdd-a1fd19f9ca-HPG8-10.1.x86_64.rpm","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWBXQ and MB008000GWBYL Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"supported_operating_systems":[{"os":"Linux","version":["7.0","8.0","9.0","12.0","15.0"]}],"supported_platforms":false,"supported_products":[]},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp052252.exe","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27"}],"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.50","description":"For Gen11 server iLO version 1.50 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.95","description":"For Gen10 server iLO version 2.95 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.22","description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"03.01.23.072","description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update."}]}]}]},"name":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW","per_device_install_time_seconds":300,"reboot_required":"no","support_url":"","supported_devices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":true,"supported_products":["A46","U47","U47"]},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp056896.zip","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec38df96d3","20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48","20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821"],"type_of_change":"1","version":"2022.11.09","vib_list":[{"name":"nmlx5-core","version":"4.22.73.1004-1OEM.703.0.0.18644231"},{"name":"nmlx5-rdma","version":"4.22.73.1004-1OEM.703.0.0.18644231"}]}],"installation_dependency":{},"name":"Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 \"nmlx5_en\" Driver Component for VMware ESXi 7.0 Update 3","per_device_install_time_seconds":360,"reboot_required":"yes","support_url":"","supported_devices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"supported_operating_systems":[{"os":"VMware","version":["7.0"]}],"supported_platforms":false,"supported_products":["U13","A41","U17","P86","U65","U43","U38","U38","A43","A42","A42","A43","U45","A56","U40","U15","U41","U12","U13","U32","A42","U14","U30","U58","U25","U24","P85","A55","U21","U50","U19","U22","P89","U50","U54","U61","U58","U63","U65","A43","A47","U54","U14","P99","P89","P89","U37","U15","U36","U34","U30","U57","A48","P92","U34","U20","U20","U47","U47","U47","U47","U56","A40","A56","A46","U46","U54","U46","U39","U46","A55","U62","U59","U58","U31","U31"]},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"component_location":[],"files":[{"name":"cp055170.exe","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5"}],"installation_dependency":{},"name":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives","per_device_install_time_seconds":120,"reboot_required":"no","support_url":"","supported_devices":["4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3330-3834-304a57465756"],"supported_operating_systems":[{"os":"Windows","version":["10.0.14393.17599","10.0.17600.18999","10.0.20317"]}],"supported_platforms":false,"supported_products":[]}]}